Lumbar total disc replacement: correlation of clinical outcome and radiological parameters

被引:12
|
作者
Boss, Oliver L. [1 ]
Tomasi, S. Ottavio [1 ]
Baeurle, Barbara [1 ]
Sgier, Friedrich [1 ]
Hausmann, Oliver N. [1 ]
机构
[1] Hirslanden Clin St Anna, Neuro & Spine Ctr, CH-6006 Luzern, Switzerland
关键词
Lumbar total disc replacement; Arthroplasty; Outcome; Radiology; CHARITE(TM) ARTIFICIAL DISC; LOW-BACK-PAIN; FOLLOW-UP; PRODISC-II; SPINE; ARTHROPLASTY; FUSION; INSTRUMENT; HEALTH; DEGENERATION;
D O I
10.1007/s00701-013-1774-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of this study was to correlate various radiological parameters with clinical outcome in patients who had undergone lumbar total disc replacement (TDR). Lumbar TDR is one possible treatment option in patients with low back pain (LBP), offering an alternative to lumbar fusion. Favourable clinical outcome hinges on a number of radiological parameters, such as mobility, sintering, and-most importantly-accurate positioning of the implant. A total of 46 patients received a prosthetic disc because of degenerative lumbar disc disorders. Follow-up evaluation included analysis of radiographs and subjective rating of the clinical status by the patient using the North American Spine Society (NASS) patient questionnaire, visual analogue scale (VAS) for pain and state of health, and the EuroQol EQ-5D. Radiological follow-up took place after 2 years. Coronal and sagittal positions of the prosthesis, intervertebral disc height, facet joint pressure, mobility, sintering, and calcification were evaluated. Optimal positioning of the prosthesis was defined as a central coronal position and a most dorsal position in the sagittal plane. Based on the radiologically determined placement of the prosthesis, the patient population was divided into three groups, i.e., prosthesis ideally placed (< 2 mm), discretely shifted (2-3 mm), or suboptimally placed (> 3 mm). Overall, 81 % of patients stated that they would undergo the operation again. Health status was stable at a VAS score of 7.04 points 2 years after TDR, compared to 3.97 points before TDR. Mean working capacity had increased from 53 % preoperatively to 88 % 2 years after TDR. Overall, 39 % of the prostheses were rated as ideally positioned, while 13 % were discretely shifted and 48 % were suboptimally placed with respect to one of the radiological criteria. In 80.4 % of patients, follow-up assessment after a parts per thousand yen2 years indicated good mobility at the operated segment, while calcification was noted in 4 % and sintering was detected in 15 % of the implants. Our data indicate poor correlation between clinical outcome and position of the prosthesis. Although 48 % of the implants were suboptimally placed in either the coronal or sagittal plane, most of the patients reached a very good clinical outcome. However, suboptimally placed devices appeared to cause significantly more neurological symptoms in long-term follow-up.
引用
收藏
页码:1923 / 1930
页数:8
相关论文
共 50 条
  • [41] Heterotopic ossification following lumbar total disc replacement
    Park, Se-Jun
    Kang, Kyung-Jung
    Shin, Seong-Kee
    Chung, Sung-Soo
    Lee, Chong-Suh
    [J]. INTERNATIONAL ORTHOPAEDICS, 2011, 35 (08) : 1197 - 1201
  • [42] Challenges and Solutions for Lumbar Total Disc Replacement Implantation
    Janssen, Michael
    Garcia, Rolando
    Miller, Lynn
    Reed, William
    Zigler, Jack
    Ferko, Nicole
    Hollmann, Sarah
    [J]. SPINE, 2017, 42 (24) : S108 - S111
  • [43] Two-level total lumbar disc replacement
    Mario Di Silvestre
    Georgios Bakaloudis
    Francesco Lolli
    Francesco Vommaro
    Patrizio Parisini
    [J]. European Spine Journal, 2009, 18 : 64 - 70
  • [44] Heterotopic ossification following lumbar total disc replacement
    Se-Jun Park
    Kyung-Jung Kang
    Seong-Kee Shin
    Sung-Soo Chung
    Chong-Suh Lee
    [J]. International Orthopaedics, 2011, 35 : 1197 - 1201
  • [45] Two-level total lumbar disc replacement
    Di Silvestre, Mario
    Bakaloudis, Georgios
    Lolli, Francesco
    Vommaro, Francesco
    Parisini, Patrizio
    [J]. EUROPEAN SPINE JOURNAL, 2009, 18 : S64 - S70
  • [46] Process for Consensus Statements on Lumbar Total Disc Replacement
    Ferko, Nicole
    Hollmann, Sarah
    [J]. SPINE, 2017, 42 (24) : S101 - S102
  • [47] Effect of Total Lumbar Disc Replacement on Lumbosacral Lordosis
    Kasliwal, Manish K.
    Deutsch, Harel
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (07): : 370 - 373
  • [48] Total lumbar disc replacement in athletes: clinical results, return to sport and athletic performance
    Christoph J. Siepe
    Karsten Wiechert
    Mohamed F. Khattab
    Andreas Korge
    H. Michael Mayer
    [J]. European Spine Journal, 2007, 16 : 1001 - 1013
  • [49] Total lumbar disc replacement in athletes: clinical results, return to sport and athletic performance
    Siepe, Christoph J.
    Wiechert, Karsten
    Khattab, Mohamed F.
    Korge, Andreas
    Mayer, H. Michael
    [J]. EUROPEAN SPINE JOURNAL, 2007, 16 (07) : 1001 - 1013
  • [50] The effect of component malalignment on the clinical and radiological outcome of the Kinemax total knee replacement
    Bankes, MJK
    Back, DL
    Cannon, SR
    Briggs, TWR
    [J]. KNEE, 2003, 10 (01): : 55 - 60