Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: A systematic review and meta-analysis

被引:91
|
作者
Cheng, Hao-Min [1 ,2 ,3 ]
Lang, Dora [1 ,4 ]
Tufanaru, Catalin [1 ]
Pearson, Alan [1 ]
机构
[1] Univ Adelaide, Fac Hlth Sci, Joanna Briggs Inst, Adelaide, SA 5005, Australia
[2] Taipei Vet Gen Hosp, Dept Med Res & Educ, Taipei, Taiwan
[3] Natl Yang Ming Univ, Dept Med, Taipei 112, Taiwan
[4] Natl Univ Singapore Hosp, Ctr Evidence Based Nursing, Singapore 117548, Singapore
关键词
Central blood pressure; Applanation tonometry; Transfer function; SphygmoCor; Late systolic peak; Sphygmomanometer; CENTRAL AORTIC PRESSURE; ARTERIAL TRANSFER-FUNCTIONS; LOW-DOSE COMBINATION; WAVE-FORM; PULSE PRESSURE; CARDIOVASCULAR EVENTS; UPPER-LIMB; HYPERTENSIVE SUBJECTS; VALIDATION; DERIVATION;
D O I
10.1016/j.ijcard.2012.04.155
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: Non-invasive methods based on applanation tonometry have been proposed to estimate central blood pressure. However, the accuracy of these methods hasn't been systematically examined. Methods: We performed a systematic review and meta-analysis of studies comparing estimated and invasively measured central BP. Results: Sufficient data were available in 22 studies for meta-analysis (857 subjects and 1167 measurements). Acquired arterial pressure waveforms in these studies were directly measured, calibrated to match invasive aortic mean BP and diastolic BP or calibrated to match brachial BP measured with a sphygmomanometer, cuff BP. Of the former 2 conditions, the errors of estimated central BP were small with a mean and standard deviation of difference -1.1 +/- 4.1 mm Hg (95% limits of agreement -9.1-6.9 mm Hg) for central systolic BP; -0.5 +/- 2.1 mm Hg (-4.6-3.6 mm Hg) for central diastolic BP; and -0.8 +/- 5.1 mm Hg (-10.8-9.2 mm Hg) for central pulse pressure. However, the errors inflated to -8.2 +/- 10.3 mm Hg (-28.4-12.0 mm Hg) for central systolic BP, 7.6 +/- 8.7 mm Hg (-9.5-24.6 mm Hg) for central diastolic BP, and -12.2 +/- 10.4 mm Hg (-32.5-8.1 mm Hg) for central pulse pressure, when calibrated to cuff BP. The findings were still evident in subgroup analysis conducted with different central BP estimating methods and validated cuff BP monitors. Conclusion: Present tonometry-based central BP estimating methods are acceptable in theory, with small errors. However, based on current available evidence, there is substantial room for improvement in measurement accuracy of central BP when cuff BP is used to calibrate the peripheral waveforms. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1867 / 1876
页数:10
相关论文
共 50 条
  • [1] Brachial Blood Pressure Invasively and Non-Invasively Obtained Using Oscillometry and Applanation Tonometry: Impact of Mean Blood Pressure Equations and Calibration Schemes on Agreement Levels
    Bia, Daniel
    Zocalo, Yanina
    Sanchez, Ramiro
    Torrado, Juan F.
    Lev, Gustavo
    Mendiz, Oscar
    Pessana, Franco
    Ramirez, Agustin
    Cabrera-Fischer, Edmundo I.
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (02)
  • [2] The Barriers to Clinical Application of Non-invasively Obtained Central Blood Pressure
    Cheng, Hao-Min
    Chen, Chen-Huan
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 233 - 236
  • [3] Accuracy of malaria diagnostic tests performed on non-invasively collected samples: a systematic review and meta-analysis
    Danwang, Celestin
    Noubiap, Jean Jacques
    Souopgui, Jacob
    Gaudart, Jean
    Yombi, Jean Cyr
    Robert, Annie
    BMJ GLOBAL HEALTH, 2021, 6 (06):
  • [4] Accuracy of automated blood pressure measurement in the presence of atrial fibrillation: systematic review and meta-analysis
    McDonagh, Sinead
    McManus, Richard
    Clark, Christopher
    JOURNAL OF HUMAN HYPERTENSION, 2018, 32 (10) : 706 - 706
  • [5] The effect of non-invasively obtained central blood pressure on cardiovascular outcome in diabetic patients in Assiut University Hospitals
    El Toony, Lobna F.
    Ramzy, Andrew N.
    Abozaid, Mohamed A. A.
    EGYPTIAN JOURNAL OF INTERNAL MEDICINE, 2022, 34 (01):
  • [6] The effect of non-invasively obtained central blood pressure on cardiovascular outcome in diabetic patients in Assiut University Hospitals
    Lobna F. El Toony
    Andrew N. Ramzy
    Mohamed A. A. Abozaid
    The Egyptian Journal of Internal Medicine, 2022, 34
  • [7] Regarding the accuracy of generalized transfer functions for estimating central aortic blood pressure when calibrated non-invasively
    Lehmann, ED
    JOURNAL OF HYPERTENSION, 2000, 18 (03) : 347 - 349
  • [8] Noninvasive estimation of central blood pressure and analysis of pulse waves by applanation tonometry
    Paolo Salvi
    Andrea Grillo
    Gianfranco Parati
    Hypertension Research, 2015, 38 : 646 - 648
  • [9] Noninvasive estimation of central blood pressure and analysis of pulse waves by applanation tonometry
    Salvi, Paolo
    Grillo, Andrea
    Parati, Gianfranco
    HYPERTENSION RESEARCH, 2015, 38 (10) : 646 - 648
  • [10] Diagnostic accuracy of mercurial versus digital blood pressure measurement devices: a systematic review and meta-analysis
    Malaisamy Muniyandi
    Senthil Sellappan
    Vidya Chellaswamy
    Karunya Ravi
    Sananthya Karthikeyan
    Kannan Thiruvengadam
    Jerard Maria Selvam
    Nagarajan Karikalan
    Scientific Reports, 12