Nonsuture dural repair using polyglycolic acid mesh and fibrin glue: Clinical application to spinal surgery

被引:67
|
作者
Hida, K [1 ]
Yamaguchi, S
Seki, T
Yano, S
Akino, M
Terasaka, S
Uchida, T
Iwasaki, Y
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Neurosurg, Sapporo, Hokkaido 0608638, Japan
[2] Sapporo Azabu Neurosurg Hosp, Sapporo, Hokkaido 0070840, Japan
[3] Teine Keijinkai Hosp, Dept Neurosurg, Sapporo, Hokkaido 0068555, Japan
[4] Chemo Sero Therapeut Res Inst, Kumamoto 8608568, Japan
来源
SURGICAL NEUROLOGY | 2006年 / 65卷 / 02期
关键词
dura substitute; CSF leakage; fibrin glue; polyglycolic acid; duroplasty;
D O I
10.1016/j.surneu.2005.07.059
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: In spinal surgery, repair of the dura is difficult when it is tom or fragile or is ossified as in cases with ossification of posterior longitudinal ligament. We report our experience with a nonsuture dural repair technique in patients undergoing spinal surgery; it uses a dura substitute composed of polyglycolic acid (PGA) mesh and fibrin glue. Here, we report the efficacy and safety of nonsuture duroplasty using PGA mesh and fibrin glue (PGA-fibrin sheet). Methods: The artificial dura mater is composed of a PGA-fibrin sheet. The dural defect is covered with a patch sprayed with fibrin glue without suturing to the dura mater. We first evaluated this technique in an experimental study by performing water leakage tests. Between May 2001 and January 2005, we used it in 160 spinal surgeries that required intraoperative dura repair. Results: Our preliminary tests showed that the threshold for water pressure without leakage was 161 +/- 42 and 96.5 +/- 32 mm Hg when the unsprayed margin around the perimeter of the patch was 5 and 2 mm, respectively. Of the 160 operated patients, 10 (6.3%) experienced subcutaneous cerebrospinal fluid (CSF) leakage. Of these, 6 required a second operation; in the other 4, the CSF collection diminished spontaneously. There were no other complications such as allergic reaction, adhesion, or infection. Conclusion: In combination with CSF diversion, the PGA-fibrin sheet is a viable alternative method for dural repair in spinal surgery. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:136 / 143
页数:8
相关论文
共 50 条
  • [41] Comparison of the Clinical Outcome and Complications in Laparoscopic Hernia Repair of Inguinal Hernia With Mesh Fixation Using Fibrin Glue vs Tacker
    Chandra, Prasant
    Phalgune, Deepak
    Shah, Shashank
    INDIAN JOURNAL OF SURGERY, 2016, 78 (06) : 464 - 470
  • [42] Comparison of the Clinical Outcome and Complications in Laparoscopic Hernia Repair of Inguinal Hernia With Mesh Fixation Using Fibrin Glue vs Tacker
    Prasant Chandra
    Deepak Phalgune
    Shashank Shah
    Indian Journal of Surgery, 2016, 78 : 464 - 470
  • [43] Filling and shielding for postoperative gastric perforations of endoscopic submucosal dissection using polyglycolic acid sheets and fibrin glue
    Takimoto, Kengo
    Hagiwara, Akeo
    ENDOSCOPY INTERNATIONAL OPEN, 2016, 4 (06) : E661 - E664
  • [44] Discussion: Three-Year Clinical Outcomes and Quality of Life after Retromuscular Resorbable Mesh Repair Using Fibrin Glue
    Rudolph, Christina
    Patel, Ashit
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2022, 149 (06) : 1448 - 1449
  • [45] Arthroscopic meniscal repair using fibrin glue .2. Clinical applications
    Ishimura, M
    Ohgushi, H
    Habata, T
    Tamai, S
    Fujisawa, Y
    ARTHROSCOPY, 1997, 13 (05): : 558 - 563
  • [46] Successful closure of a large perforation during colorectal endoscopic submucosal dissection by application of polyglycolic acid sheets and fibrin glue
    Sakaguchi, Yoshiki
    Tsuji, Yosuke
    Yamamichi, Nobutake
    Fujishiro, Mitsuhiro
    Koike, Kazuhiko
    GASTROINTESTINAL ENDOSCOPY, 2016, 84 (02) : 374 - 375
  • [47] Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh
    Massullo, James M.
    Singh, Tejinder P.
    Dunnican, Ward J.
    Binetti, Brian R.
    JSLS-JOURNAL OF THE SOCIETY OF LAPAROENDOSCOPIC SURGEONS, 2012, 16 (01) : 55 - 59
  • [48] Clinical evaluations of autologous fibrin glue and polyglycolic acid sheets as oral surgical wound coverings after partial glossectomy
    Kouketsu, Atsumu
    Nogami, Shinnosuke
    Fujiwara, Minami
    Mori, Shiro
    Yamauchi, Kensuke
    Hashimoto, Wataru
    Miyashita, Hitoshi
    Kurihara, Jun
    Kawai, Tadashi
    Higuchi, Keisuke
    Takahashi, Tetsu
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (08) : 964 - 968
  • [49] Effective Repair of Dural Tear Using Bioabsorbable Sheet with Fibrin Glue (vol 42, pg 1362, 2017)
    Iwata, A.
    Takahata, M.
    Kadoya, K.
    SPINE, 2021, 46 (21) : E1168 - E1168
  • [50] Efficacy and safety of non-suture dural closure using a novel dural substitute consisting of polyglycolic acid felt and fibrin glue to prevent cerebrospinal fluid leakage—A non-controlled, open-label, multicenter clinical trial—
    Shunsuke Terasaka
    Toshiaki Taoka
    Satoshi Kuroda
    Nobutaka Mikuni
    Toru Nishi
    Hiroyuki Nakase
    Yukihiko Fujii
    Yasuhiko Hayashi
    Jun-ichi Murata
    Ken-ichiro Kikuta
    Toshihiko Kuroiwa
    Sachie Shimokawa
    Kiyohiro Houkin
    Journal of Materials Science: Materials in Medicine, 2017, 28