Nonsuture dural repair using polyglycolic acid mesh and fibrin glue: Clinical application to spinal surgery

被引:67
|
作者
Hida, K [1 ]
Yamaguchi, S
Seki, T
Yano, S
Akino, M
Terasaka, S
Uchida, T
Iwasaki, Y
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Neurosurg, Sapporo, Hokkaido 0608638, Japan
[2] Sapporo Azabu Neurosurg Hosp, Sapporo, Hokkaido 0070840, Japan
[3] Teine Keijinkai Hosp, Dept Neurosurg, Sapporo, Hokkaido 0068555, Japan
[4] Chemo Sero Therapeut Res Inst, Kumamoto 8608568, Japan
来源
SURGICAL NEUROLOGY | 2006年 / 65卷 / 02期
关键词
dura substitute; CSF leakage; fibrin glue; polyglycolic acid; duroplasty;
D O I
10.1016/j.surneu.2005.07.059
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: In spinal surgery, repair of the dura is difficult when it is tom or fragile or is ossified as in cases with ossification of posterior longitudinal ligament. We report our experience with a nonsuture dural repair technique in patients undergoing spinal surgery; it uses a dura substitute composed of polyglycolic acid (PGA) mesh and fibrin glue. Here, we report the efficacy and safety of nonsuture duroplasty using PGA mesh and fibrin glue (PGA-fibrin sheet). Methods: The artificial dura mater is composed of a PGA-fibrin sheet. The dural defect is covered with a patch sprayed with fibrin glue without suturing to the dura mater. We first evaluated this technique in an experimental study by performing water leakage tests. Between May 2001 and January 2005, we used it in 160 spinal surgeries that required intraoperative dura repair. Results: Our preliminary tests showed that the threshold for water pressure without leakage was 161 +/- 42 and 96.5 +/- 32 mm Hg when the unsprayed margin around the perimeter of the patch was 5 and 2 mm, respectively. Of the 160 operated patients, 10 (6.3%) experienced subcutaneous cerebrospinal fluid (CSF) leakage. Of these, 6 required a second operation; in the other 4, the CSF collection diminished spontaneously. There were no other complications such as allergic reaction, adhesion, or infection. Conclusion: In combination with CSF diversion, the PGA-fibrin sheet is a viable alternative method for dural repair in spinal surgery. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:136 / 143
页数:8
相关论文
共 50 条
  • [21] Extended application of polyglycolic acid sheet combined with sprayed fibrin glue to advanced oral cancers
    Honda, K.
    Asato, R.
    Tsuji, J.
    Kanda, T.
    Ushiro, K.
    Watanabe, Y.
    ORAL ONCOLOGY, 2011, 47 : S151 - S151
  • [22] CLINICAL-APPLICATION OF FIBRIN GLUE IN CARDIOVASCULAR-SURGERY
    KOVEKER, G
    THORACIC AND CARDIOVASCULAR SURGEON, 1982, 30 (04): : 228 - 229
  • [23] Pulmonary resection using polyglycolic acid sheet without fibrin glue and its surgical complications
    Endoh, Hideki
    Yamamoto, Ryohei
    Nishizawa, Nobuhiro
    Satoh, Yukitoshi
    VIDEO-ASSISTED THORACIC SURGERY, 2024, 9
  • [24] Postoperative bronchial stump fistula after lobectomy: Response to occlusion with polyglycolic acid mesh and fibrin glue via bronchoscopy
    Imai K.
    Matsuzaki I.
    Minamiya Y.
    Saito H.
    Yoshida S.
    Hirayama K.
    Sawano T.
    Ogawa J.-I.
    General Thoracic and Cardiovascular Surgery, 2011, 59 (11) : 771 - 774
  • [25] Polyglycolic Acid Mesh and Fibrin Glue in Minimally Invasive Left Pancreatectomy: Video Technique and Single-Center Data
    Baba, Hayato
    Oba, Atsushi
    Maekawa, Aya
    Kiritani, Sho
    Kobayashi, Hiroshi
    Takahashi, Atsushi
    Omiya, Kojiro
    Kobayashi, Kosuke
    Ono, Yoshihiro
    Sato, Takafumi
    Ito, Hiromichi
    Inoue, Yosuke
    Takahashi, Yu
    ANNALS OF SURGICAL ONCOLOGY, 2025,
  • [26] Hemopatch® with fibrin glue as a dural sealant in cranial and spinal surgery. A technical note with a review of the literature
    Montano, Nicola
    Giordano, Martina
    Caccavella, Valerio Maria
    Ioannoni, Eleonora
    Polli, Filippo Maria
    Papacci, Fabio
    Olivi, Alessandro
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 79 : 144 - 147
  • [27] Simple Intraoperative Technique for Minor Dural Gap Repair Using Fibrin Glue and Oxidized Cellulose
    Gazzeri, Roberto
    Galarza, Marcelo
    Alfieri, Alex
    Neroni, Massimiliano
    Roperto, Raffaelino
    WORLD NEUROSURGERY, 2011, 76 (1-2) : 173 - 175
  • [28] Localized controlled fibrin glue application with gelatin sponge for hemostasis and dural defect repair: Technical note
    Nagahama, Yasunori
    Li, Luyuan
    Takeda, Masaaki
    Mitsuhara, Takafumi
    Kurisu, Kaoru
    Howard, Matthew A., III
    Hitchon, Patrick W.
    Yamaguchi, Satoshi
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2019, 18
  • [29] Low-voltage coagulation, polyglycolic acid sheets, and fibrin glue to control air leaks in lung surgery
    Norikazu Kawai
    Takeshi Kawaguchi
    Shuko Suzuki
    Motoaki Yasukawa
    Takashi Tojo
    Shigeki Taniguchi
    General Thoracic and Cardiovascular Surgery, 2017, 65 : 705 - 709
  • [30] Low-voltage coagulation, polyglycolic acid sheets, and fibrin glue to control air leaks in lung surgery
    Kawai, Norikazu
    Kawaguchi, Takeshi
    Suzuki, Shuko
    Yasukawa, Motoaki
    Tojo, Takashi
    Taniguchi, Shigeki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2017, 65 (12) : 705 - 709