Nonsuture dural repair using polyglycolic acid mesh and fibrin glue: Clinical application to spinal surgery

被引:67
|
作者
Hida, K [1 ]
Yamaguchi, S
Seki, T
Yano, S
Akino, M
Terasaka, S
Uchida, T
Iwasaki, Y
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Neurosurg, Sapporo, Hokkaido 0608638, Japan
[2] Sapporo Azabu Neurosurg Hosp, Sapporo, Hokkaido 0070840, Japan
[3] Teine Keijinkai Hosp, Dept Neurosurg, Sapporo, Hokkaido 0068555, Japan
[4] Chemo Sero Therapeut Res Inst, Kumamoto 8608568, Japan
来源
SURGICAL NEUROLOGY | 2006年 / 65卷 / 02期
关键词
dura substitute; CSF leakage; fibrin glue; polyglycolic acid; duroplasty;
D O I
10.1016/j.surneu.2005.07.059
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: In spinal surgery, repair of the dura is difficult when it is tom or fragile or is ossified as in cases with ossification of posterior longitudinal ligament. We report our experience with a nonsuture dural repair technique in patients undergoing spinal surgery; it uses a dura substitute composed of polyglycolic acid (PGA) mesh and fibrin glue. Here, we report the efficacy and safety of nonsuture duroplasty using PGA mesh and fibrin glue (PGA-fibrin sheet). Methods: The artificial dura mater is composed of a PGA-fibrin sheet. The dural defect is covered with a patch sprayed with fibrin glue without suturing to the dura mater. We first evaluated this technique in an experimental study by performing water leakage tests. Between May 2001 and January 2005, we used it in 160 spinal surgeries that required intraoperative dura repair. Results: Our preliminary tests showed that the threshold for water pressure without leakage was 161 +/- 42 and 96.5 +/- 32 mm Hg when the unsprayed margin around the perimeter of the patch was 5 and 2 mm, respectively. Of the 160 operated patients, 10 (6.3%) experienced subcutaneous cerebrospinal fluid (CSF) leakage. Of these, 6 required a second operation; in the other 4, the CSF collection diminished spontaneously. There were no other complications such as allergic reaction, adhesion, or infection. Conclusion: In combination with CSF diversion, the PGA-fibrin sheet is a viable alternative method for dural repair in spinal surgery. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:136 / 143
页数:8
相关论文
共 50 条
  • [1] The dural repair using the combination of polyglycolic acid mesh and fibrin glue and postoperative management in spine surgery
    Masuda, Soichiro
    Fujibayashi, Shunsuke
    Otsuki, Bungo
    Kimura, Hiroaki
    Neo, Masashi
    Matsuda, Shuichi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (05) : 586 - 590
  • [2] Dural substitute with polyglycolic acid mesh and fibrin glue for dural repair: technical note and preliminary results
    Shimada, Yoichi
    Hongo, Michio
    Miyakoshi, Naohisa
    Sugawara, Taku
    Kasukawa, Yuji
    Ando, Shigeru
    Ishikawa, Yoshinori
    Itoi, Eiji
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (05) : 454 - 458
  • [3] Spinal Cord Herniation after Dural Defect Repaired Using Polyglycolic Acid Mesh and Fibrin Glue: A Case Report
    Kozaki, Takuhei
    Iwasaki, Hiroshi
    Nagata, Keiji
    Hoshino, Akihiro
    Hirai, Kazunari
    Kozaki, Takahiro
    Yamada, Hiroshi
    SPINE SURGERY AND RELATED RESEARCH, 2023, 7 (06): : 551 - 554
  • [4] A foreign body granuloma after the usage of polyglycolic acid mesh and fibrin glue for dural repair. A case report
    Kawabata, Atsuyuki
    Inose, Hiroyuki
    Ukegawa, Dai
    Kawabata, Shigenori
    Yamada, Tsuyoshi
    Okawa, Atsushi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (02) : 371 - 374
  • [5] Reinforcement of Pancreticojejunostomy Using Polyglycolic Acid Mesh and Fibrin Glue Sealant
    Satoi, Sohei
    Toyokawa, Hideyoshi
    Yanagimoto, Hiroaki
    Yamamoto, Tomohisa
    Hirooka, Satoshi
    Yui, Rintaro
    Yamaki, So
    Matsui, Yoichi
    Mergental, Hynek
    Kwon, A-Hon
    PANCREAS, 2011, 40 (01) : 16 - 20
  • [6] A novel method of dural repair using polyglycolic acid non-woven fabric and fibrin glue: Clinical results of 140 cases
    Terasaka, Shunsuke
    Iwasaki, Yoshinobu
    Kuroda, Satoshi
    Uchida, Takanori
    NEUROLOGICAL SURGERY, 2006, 34 (11): : 1109 - 1117
  • [7] Fibrin glue and polyglycolic acid nonwoven fabric as a biocompatible dural substitute
    Terasaka, S
    Iwasaki, Y
    Shinya, N
    Uchida, T
    NEUROSURGERY, 2006, 58 (02) : 134 - 138
  • [8] Fibrin glue and polyglycolic acid nonwoven fabric as a biocompatible dural substitute - Comments
    Kawase, T
    Bruce, JN
    Kaye, AH
    NEUROSURGERY, 2006, 58 (02) : 138 - 139
  • [9] Clinical Evaluation of Application of Polyglycolic Acid Sheet and Fibrin Glue Spray for Partial Glossectomy
    Takeuchi, Junichiro
    Suzuki, Hiroaki
    Murata, Maho
    Kakei, Yasumasa
    Ri, Shinshou
    Umeda, Masahiro
    Komori, Takahide
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (02) : E126 - E131
  • [10] Defect repair with fibrin glue/polyglycolic acid after endoscopic laryngopharyngeal cancer resection
    Watanabe, Yoshiki
    Tanaka, Shinzo
    Hiratsuka, Yasuyuki
    Yamazaki, Hiroshi
    Yoshida, Takao
    Kusano, Junko
    Matsunaga, Momoko
    Kitano, Masayuki
    Nakahira, Mai
    Oe, Kengo
    LARYNGOSCOPE, 2020, 130 (07): : 1740 - 1745