Intramedullary Cortical Button Repair for Distal Biceps Tendon Rupture: A Single-Center Experience

被引:26
|
作者
Siebenlist, Sebastian [1 ]
Schmitt, Andreas [1 ]
Imhoff, Andreas B. [1 ]
Lenich, Andreas [3 ]
Sandmann, Gunther H. [4 ]
Braun, Karl F. [2 ]
Kirchhoff, Chlodwig [2 ]
Biberthaler, Peter [2 ]
Buchholz, Arne [2 ]
机构
[1] Tech Univ Munich, Univ Hosp Rechts Isar, Dept Orthopaed Sports Med, Munich, Germany
[2] Tech Univ Munich, Univ Hosp Rechts Isar, Clin Trauma Surg, Ismaninger Str 22, D-81675 Munich, Germany
[3] HELIOS Clin Munich West, Clin Trauma Surg Orthoped & Sports Orthoped, Munich, Germany
[4] Sportsclin Ravensburg, Ravensburg, Germany
来源
关键词
Distal biceps tendon; heterotopic ossification; intramedullary cortical button; posterior interosseous nerve; POSTERIOR INTEROSSEOUS NERVE; ENDOBUTTON REPAIR; INCISION REPAIR; HETEROTOPIC OSSIFICATION; BICIPITAL TUBEROSITY; BRACHII TENDON; FIXATION; ANATOMY; ELBOW; COMPLICATIONS;
D O I
10.1016/j.jhsa.2018.07.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The aim of this retrospective study was to evaluate the clinical outcome and complication rate of intramedullary cortical button repair for distal biceps tendon rupture (partial and complete tears). Methods Between 2010 and 2014, a total of 28 patients with an acute distal biceps tendon rupture underwent intramedullary cortical button repair. Twenty-four patients (mean age, 49 years) with a mean follow-up of 28 months were included in the study. Twenty patients were examined clinically and by maximum isometric strength testing in flexion (at 90 degrees) and supination of both arms. Twenty-four patients completed functional scores including the Mayo Elbow Performance Score (MEPS), the Andrews-Carson-Score (ACS) and the shortened Disabilities of the Arm, Shoulder, and Hand (QuickDASH) questionnaire. Furthermore, follow-up radiographs of 24 patients were analyzed. Results Compared with the contralateral elbow, the active range of motion (ROM) was the same. The mean strength for flexion was 100.8% +/- 14% and for supination 93.1% +/- 22% compared with the uninjured side. The mean MEPS for all patients was 95.6 +/- 8.2, the mean ACS 194.2 +/- 9.4 and the QuickDASH 3.8 +/- 7.6. Heterotopic ossification (HO) was seen on radiographs in 46% of patients, but was symptomatic in only 1 patient. One patient suffered a tendon rerupture, and 1 asymptomatic button migration was seen in the follow-up. Conclusions Intramedullary cortical button repair provides good results with respect to strength, ROM, and functional outcomes. Because the posterior cortex is not violated, the risk of iatrogenic posterior interosseous nerve injury is minimized. However, the patient should be warned of a high prevalence of postoperative HO. Copyright (C) 2019 by the American Society for Surgery of the Hand. All rights reserved.
引用
收藏
页码:418.e1 / 418.e7
页数:7
相关论文
共 50 条
  • [21] Intramedullary button refixation of the distal biceps tendon in a single incision technique Surgical technique (approach of the authors)
    Voelk, C.
    Siebenlist, S.
    Kirchhoff, C.
    Biberthaler, P.
    Buchholz, A.
    UNFALLCHIRURG, 2019, 122 (10): : 812 - 813
  • [22] Nanoscopic Distal Biceps Repair With Cortical Button and Interference Screw
    Reinares, Felipe
    de la Maza, Francisca
    de la Paz, Joaquin
    Angulo, Manuela
    Lecaros, Juan Jose
    Jimenez, Francisco Ruiz
    ARTHROSCOPY TECHNIQUES, 2023, 12 (02): : E153 - E159
  • [23] Single-Incision Distal Biceps Tendon Repair With Bicortical Tensionable Locking Button Fixation
    Khan, Zeeshan A.
    Kerzner, Benjamin
    Jackson, Garrett R.
    Jawanda, Harkirat S.
    Mccormick, Johnathon R.
    Brusalis, Christopher M.
    Chan, Jimmy J.
    Kaplan, Daniel J.
    Verma, Nikhil N.
    ARTHROSCOPY TECHNIQUES, 2023, 12 (11): : E2063 - E2069
  • [24] The rupture of the distal biceps tendon
    Bauer, Gerhard J.
    Hingelbaum, S.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2008, 3 (02): : 101 - 107
  • [25] Rupture of the distal biceps tendon
    Engler, Cedric
    Grezda, Kushtrim
    Rosso, Claudio
    ARTHROSKOPIE, 2023, 36 (01) : 25 - 35
  • [26] Rupture of the distal biceps tendon
    Jung, W.
    Kortmann, H-R
    TRAUMA UND BERUFSKRANKHEIT, 2005, 7 (03) : 153 - 156
  • [27] Rupture of the distal biceps tendon
    Voelk, C.
    Siebenlist, S.
    Kirchhoff, C.
    Biberthaler, P.
    Buchholz, A.
    UNFALLCHIRURG, 2019, 122 (10): : 799 - 811
  • [28] DISTAL BICEPS TENDON RUPTURE
    Sherman, Scott C.
    Afifi, Negean
    JOURNAL OF EMERGENCY MEDICINE, 2012, 43 (06): : E469 - E470
  • [29] Distal biceps tendon rupture
    Olga D. Savvidou
    Panayiotis J. Papagelopoulos
    Andreas F. Mavrogenis
    Antonios A. Partsinevelos
    Efthymios J. Karadimas
    Demetrios S. Korres
    European Journal of Orthopaedic Surgery & Traumatology, 2006, 16 (4) : 400 - 400
  • [30] Single incision, transosseous suture repair technique for acute distal biceps tendon rupture
    Yu, CO
    Caputo, AE
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2003, 11 (01) : 51 - 54