Experience with Frequency Response Analysis (FRA) for the Mechanical Condition Assessment of Transformer Windings

被引:0
|
作者
Picher, Patrick [1 ]
Rajotte, Claude [2 ]
Tardif, Carl [2 ]
机构
[1] Hydroquebec IREQ, Varennes, PQ, Canada
[2] Hydro Quebec TransEnergie, Montreal, PQ, Canada
关键词
transformer; frequency response analysis;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurement of the frequency response is now commonly used in the industry to assess the mechanical condition of transformer windings. The analysis of the results, the so-called Frequency Response Analysis (FRA), is based on comparison with a reference measurement which is either a previous measurement on the same unit, a measurement on an identical transformer or a measurement on another phase of a three-phase transformer. To ensure a good quality of the frequency response measurement, it is essential to follow the recommended practices reported in the recently published CIGRE and IEEE guides, and in the IEC standard. This paper presents case studies on the application of the method to detect mechanical displacement and some of the influencing parameters that can affect the interpretation of the results.
引用
收藏
页码:220 / 224
页数:5
相关论文
共 50 条
  • [41] Practical experience on transformer insulation condition assessment
    Homagk, C.
    Leibfried, T.
    [J]. ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 238 - +
  • [42] Application of Statistical Tools in Power Transformer FRA Results Interpretation Transformer Winding Diagnosis Based on Frequency Response Analysis
    Nnachi, G. U.
    Akumu, A. O.
    Richards, C. G.
    Nicolae, D. V.
    [J]. 2017 IEEE PES POWERAFRICA CONFERENCE, 2017, : 16 - 22
  • [43] Modeling and Diagnostic Transformer Condition Using Sweep Frequency Response Analysis
    Purnomoadi, A. P.
    Fransisco, D.
    [J]. ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 1059 - +
  • [44] A New Method for Analysing Transformer Condition Using Frequency Response Analysis
    Small, Belinda J.
    Abu-Siada, A.
    [J]. 2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [45] Polar mode of frequency response analysis used for observation of transformer condition
    Iskanto, Edy
    Hargono, Herpekik
    Ari-Muchtar, S.
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 960 - 963
  • [46] Research on Dynamic Response of Power Transformer Windings under Short Circuit Condition
    Wang, Shuang
    Wang, Shuhong
    Zhu, Ting
    Zhang, Naming
    Li, Hailin
    Qiu, Hao
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [47] FEM Modelling of the Influence of the Remaining Windings on the Frequency Response of the Power Transformer
    Trela, Katarzyna
    Gawrylczyk, Konstanty Marek
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (21): : 1 - 13
  • [48] Analysis of electromagnetic force for medium frequency transformer with interleaved windings
    Huang, Pei
    Mao, Chengxiong
    Wang, Dan
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (08) : 2023 - 2030
  • [49] Transformer Winding Fault Classification and Condition Assessment Based on Random Forest Using FRA
    Tahir, Mehran
    Tenbohlen, Stefan
    [J]. ENERGIES, 2023, 16 (09)
  • [50] Circuit Model of Transformers Windings using Vector Fitting, for Frequency Response Analysis (FRA) PART II: Core Influence
    Alvarez, David L.
    Rosero, Javier A.
    Mombello, Enrique E.
    [J]. 2013 WORKSHOP ON POWER ELECTRONICS AND POWER QUALITY APPLICATIONS (PEPQA), 2013,