Experience with Frequency Response Analysis (FRA) for the Mechanical Condition Assessment of Transformer Windings

被引:0
|
作者
Picher, Patrick [1 ]
Rajotte, Claude [2 ]
Tardif, Carl [2 ]
机构
[1] Hydroquebec IREQ, Varennes, PQ, Canada
[2] Hydro Quebec TransEnergie, Montreal, PQ, Canada
关键词
transformer; frequency response analysis;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurement of the frequency response is now commonly used in the industry to assess the mechanical condition of transformer windings. The analysis of the results, the so-called Frequency Response Analysis (FRA), is based on comparison with a reference measurement which is either a previous measurement on the same unit, a measurement on an identical transformer or a measurement on another phase of a three-phase transformer. To ensure a good quality of the frequency response measurement, it is essential to follow the recommended practices reported in the recently published CIGRE and IEEE guides, and in the IEC standard. This paper presents case studies on the application of the method to detect mechanical displacement and some of the influencing parameters that can affect the interpretation of the results.
引用
收藏
页码:220 / 224
页数:5
相关论文
共 50 条
  • [21] Calculation and Analysis of Mechanical Characteristics of Transformer Windings Under Short-Circuit Condition
    Wang, Shuang
    Wang, Shuhong
    Zhang, Naming
    Yuan, Dongsheng
    Qiu, Hao
    IEEE TRANSACTIONS ON MAGNETICS, 2019, 55 (07)
  • [22] Frequency response analysis approach for condition monitoring of transformer
    Nirgude, PM
    Gunasekaran, B
    Channakeshava
    Rajkumar, AD
    Singh, BP
    2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, : 186 - 189
  • [23] Exploring possibilities for characterization of power transformer insulation by frequency response analysis (FRA)
    Abeywickrama, KGNB
    Serdyuk, YV
    Gubanski, SM
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) : 1375 - 1382
  • [24] Frequency Response Analysis (FRA) Fault Diagram Assessment Method
    Mugarra, Asier
    Mayora, Hernan
    Manuel Guerrero, Jose
    Platero, Carlos A.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (01) : 336 - 344
  • [25] Sweep frequency response analysis based diagnosis of shorts within transformer windings
    Rajamani, Rajesh
    Rajappa, Muthaiah
    Madanmohan, Balasubramanian
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (17) : 4274 - 4281
  • [26] Frequency Response Modelling of Transformer Windings Connected in Parallel
    Banaszak, Szymon
    Gawrylczyk, Konstanty Marek
    Trela, Katarzyna
    ENERGIES, 2020, 13 (06)
  • [27] High frequency model and transient response of transformer windings
    Shibuya, Y
    Fujita, S
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 1839 - 1844
  • [28] Improved FRA modeling and radial deformation fault analysis of traction transformer windings
    Zhou L.
    Li W.
    Jiang J.
    Gao S.
    Yan J.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (07): : 213 - 218
  • [29] The Fault Detection of Transformer Windings' Deformation Based on Vibration Frequency Response Analysis
    Shao, Yuying
    Guan, Hong
    Jin, Zhijian
    Rao, Zhushi
    2012 INTERNATIONAL CONFERENCE ON QUALITY, RELIABILITY, RISK, MAINTENANCE, AND SAFETY ENGINEERING (ICQR2MSE), 2012, : 713 - 718
  • [30] Experience in Using Frequency Response Analysis to Assess the Condition of a High-Power Test Transformer
    Larin, V.S.
    Zavidey, V.I.
    Volkov, A. Yu.
    Zenenko, A.S.
    Power Technology and Engineering, 2024, 58 (02) : 356 - 366