Measurement of the frequency response is now commonly used in the industry to assess the mechanical condition of transformer windings. The analysis of the results, the so-called Frequency Response Analysis (FRA), is based on comparison with a reference measurement which is either a previous measurement on the same unit, a measurement on an identical transformer or a measurement on another phase of a three-phase transformer. To ensure a good quality of the frequency response measurement, it is essential to follow the recommended practices reported in the recently published CIGRE and IEEE guides, and in the IEC standard. This paper presents case studies on the application of the method to detect mechanical displacement and some of the influencing parameters that can affect the interpretation of the results.
引用
收藏
页码:220 / 224
页数:5
相关论文
共 50 条
  • [1] Faults Investigation of Transformer Windings Using the Frequency Response Analysis FRA
    Chaouche, Moustafa Sahnoune
    Houassine, Hamza
    Moulahoum, Samir
    Colak, Ilhami
    [J]. 2016 15TH IEEE INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND APPLICATIONS (ICMLA 2016), 2016, : 452 - 459
  • [2] Frequency Response Quality Index for Assessing the Mechanical Condition of Transformer Windings
    Kornatowski, Eugeniusz
    Banaszak, Szymon
    [J]. ENERGIES, 2020, 13 (01)
  • [3] A Novel Vibration Frequency Response Analysis Method for Mechanical Condition Detection of Converter Transformer Windings
    Wu, Shuyu
    Ji, Shengchang
    Zhang, Yukun
    Wang, Shichang
    Liu, Huadong
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (07) : 8176 - 8180
  • [4] Broadband Frequency Response Analysis of Transformer Windings
    Yang, Yu
    Wang, Zanji
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (05) : 1782 - 1790
  • [5] Diagnostic possibilities of frequency response analysis of transformer windings
    Witczak, Pawel
    Wnuk, Lukasz
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 260 - 262
  • [6] A condition monitoring and fault detection in the windings of power transformer using impulse frequency response analysis
    Kumar, Ritesh
    Vaijayanthi, Adavelli
    Deshmukh, Ram
    Vedik, B.
    Shiva, Chandan Kumar
    [J]. INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2022, 13 (04) : 2062 - 2074
  • [7] A condition monitoring and fault detection in the windings of power transformer using impulse frequency response analysis
    Ritesh Kumar
    Adavelli Vaijayanthi
    Ram Deshmukh
    B. Vedik
    Chandan Kumar Shiva
    [J]. International Journal of System Assurance Engineering and Management, 2022, 13 : 2062 - 2074
  • [8] A Contribution to the Frequency Analysis and Transient Response of Power Transformer Windings
    Saied, Mohamed Mostafa
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2014, 42 (11) : 1143 - 1151
  • [9] Detection of transformer windings' deformations with frequency response analysis method
    Banaszak, Szymon
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11B): : 174 - 177
  • [10] Cross Test Comparison in Transformer Windings Frequency Response Analysis
    Banaszak, Szymon
    Szoka, Wojciech
    [J]. ENERGIES, 2018, 11 (06)