Direct electrochemistry of sarcosine oxidase on graphene, chitosan and silver nanoparticles modified glassy carbon electrode and its biosensing for hydrogen peroxide

被引:58
|
作者
Zhou, Yunlei [1 ]
Yin, Huanshun [1 ]
Meng, Xiaomeng [1 ]
Xu, Zhenning [1 ]
Fu, Yanrong [1 ]
Ai, Shiyun [1 ]
机构
[1] Shandong Agr Univ, Coll Chem & Mat Sci, Tai An 271018, Shandong, Peoples R China
关键词
Sarcosine oxidase; Direct electrochemistry; Graphene; Silver nanoparticles; Hydrogen peroxide; HORSERADISH-PEROXIDASE; IONIC LIQUID; GLUCOSE-OXIDASE; COLLOIDAL GOLD; HEME-PROTEINS; CYTOCHROME-C; ELECTROCATALYSIS; FILM; HEMOGLOBIN; MYOGLOBIN;
D O I
10.1016/j.electacta.2012.04.014
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The direct electrochemistry of sacrosine oxidase (SOX) immobilized on graphene, chitosan and silver nanoparticles (AgNPs) modified glassy carbon electrode was realized. SOX exhibits a pair of well-defined reversible redox peaks in 0.1 M pH 7.0 phosphate buffer solution (PBS) with the oxidation peak potential of-0.446V and the reduction peak potential of -0.496 V. The immobilized SOX retains its bioactivity, and exhibits a surface confined, reversible two-proton and two-electron transfer reaction. It also has good stability, and a fast heterogeneous electron transfer rate with the rate constant (k(s)) of 1.8 s(-1). The surface coverage of SOX is 1.18 x 10(-7) mol/cm(7). This biosensor shows excellent sensitivity towards H2O2 in 0.1 M PBS (pH 7.0) with a wide linear range from 1.0 to 177 mu M. The detection limit is 1.0 mu M. The apparent Michaelis-Menten constant for immobilized SOX is calculated to be 0.18 mM. The excellent performance of the biosensor is attributed to large specific surface area and high conductivity of graphene and AgNPs, and good biocompatibility of chitosan, which improve the enzyme absorption and promote direct electron transfer between SOX and the electrode surface. (C) 2012 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:294 / 301
页数:8
相关论文
共 50 条
  • [31] Amperometric cholesterol biosensor based on the direct electrochemistry of cholesterol oxidase and catalase on a graphene/ionic liquid-modified glassy carbon electrode
    Gholivand, Mohammad Bagher
    Khodadadian, Mehdi
    BIOSENSORS & BIOELECTRONICS, 2014, 53 : 472 - 478
  • [32] DIRECT ELECTROCHEMISTRY OF GLUCOSE OXIDASE AT A GOLD ELECTRODE MODIFIED WITH GRAPHENE NANOSHEETS
    Alwarappan, Subbiah
    Singh, Shree R.
    Pillai, Shreekumar
    Kumar, Ashok
    Mohapatra, Shyam
    ANALYTICAL LETTERS, 2012, 45 (07) : 746 - 753
  • [33] Glassy carbon electrode modified with gold nanoparticles and hemoglobin in a chitosan matrix for improved pH-switchable sensing of hydrogen peroxide
    Liu, Yang
    Shi, Liang
    Gong, Jin
    Fang, Yu-Ting
    Bao, Ning
    Gu, Hai-Ying
    Zeng, Jiang
    MICROCHIMICA ACTA, 2015, 182 (15-16) : 2461 - 2468
  • [34] Glassy carbon electrode modified with gold nanoparticles and hemoglobin in a chitosan matrix for improved pH-switchable sensing of hydrogen peroxide
    Yang Liu
    Liang Shi
    Jin Gong
    Yu-Ting Fang
    Ning Bao
    Hai-Ying Gu
    Jiang Zeng
    Microchimica Acta, 2015, 182 : 2461 - 2468
  • [35] A Hydrogen Peroxide Biosensor Based on Direct Electrochemistry of Hemoglobin in Palladium Nanoparticles/Graphene–Chitosan Nanocomposite Film
    Aili Sun
    Qinglin Sheng
    Jianbin Zheng
    Applied Biochemistry and Biotechnology, 2012, 166 : 764 - 773
  • [36] Modified glassy carbon electrode based on myoglobin and reduced graphene oxide for hydrogen peroxide detection
    Szoke, A.
    Turdean, G.
    Muresan, L.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 : 147 - 154
  • [37] Surface nanocrystallization of glassy carbon electrode: Application in direct electrochemistry of glucose oxidase
    Xu, Xiahong
    Chen, Jinhua
    Li, Wang
    Nie, Zhou
    Yao, Shouzhuo
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (10) : 1459 - 1462
  • [38] A glassy carbon electrode modified with a composite consisting of reduced graphene oxide, zinc oxide and silver nanoparticles in a chitosan matrix for studying the direct electron transfer of glucose oxidase and for enzymatic sensing of glucose
    Zhenjiang Li
    Liying Sheng
    Alan Meng
    Cuicui Xie
    Kun Zhao
    Microchimica Acta, 2016, 183 : 1625 - 1632
  • [39] A glassy carbon electrode modified with a composite consisting of reduced graphene oxide, zinc oxide and silver nanoparticles in a chitosan matrix for studying the direct electron transfer of glucose oxidase and for enzymatic sensing of glucose
    Li, Zhenjiang
    Sheng, Liying
    Meng, Alan
    Xie, Cuicui
    Zhao, Kun
    MICROCHIMICA ACTA, 2016, 183 (05) : 1625 - 1632
  • [40] Direct electrochemistry of glucose oxidase and biosensing for glucose based on boron-doped carbon nanotubes modified electrode
    Deng, Chunyan
    Chen, Jinhua
    Chen, Xiaoli
    Mao, Chunhui
    Nie, Lihua
    Yao, Shouzhuo
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (08): : 1272 - 1277