Co-registration of angiography and intravascular ultrasound images through image-based device tracking

被引:5
|
作者
Prasad, Megha [1 ]
Cassar, Andrew [1 ]
Fetterly, Kenneth A. [1 ]
Bell, Malcolm [1 ]
Theessen, Heike [2 ]
Ecabert, Olivier [2 ]
Bresnahan, John F. [1 ]
Lerman, Amir [1 ]
机构
[1] Mayo Clin, Sch Med, Div Cardiol, Rochester, MN USA
[2] Siemens Corp Res & Technol, Munich, Germany
关键词
imaging; integration; coronary artery disease; novel; PERCUTANEOUS CORONARY INTERVENTION; SHEAR-STRESS; TOMOGRAPHY; LESIONS; FUSION;
D O I
10.1002/ccd.26340
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesTo determine the feasibility of automated co-registration of angiography and intravascular ultrasound (IVUS) to facilitate integration of these two imaging modalities in a synchronous manner. BackgroundIVUS provides cross-sectional imaging of coronary arteries but lacks overview of the vascular territory provided by angiography. Co-registration of angiography and IVUS would increase utility of IVUS in the clinical setting. MethodsForty-nine consecutive patients undergoing surveillance for cardiac allograft vasculopathy with angiography and IVUS of the left anterior descending artery (LAD) were enrolled. A pre-IVUS angiogram of the LAD was performed followed by an ECG-triggered fluoroscopy (ECGTF) during IVUS pullback at 0.5mm/s using an automatic pullback device. ECGTF was used to track the IVUS catheter during pullback and establish a spatial relationship to the pre-IVUS angiogram. Angio-IVUS co-registration was performed with a research prototype (Siemens Healthcare, Germany) and accuracy was evaluated by distance mismatch between angiography and IVUS images at vessel bifurcations. ResultsMedian age was 54 (44.5, 67) years. The population was 82.6% male with minimal risk factors. The median (IQR) co-registration distance mismatch measured at 108 bifurcations in 42 (85%) patients was 0.35 (0.00-1.16) mm. Seven patients were excluded due to inappropriate data acquisition (n=3) and failure of tracking (n=4), e.g., due to overlapping sternal wires. Estimated effective radiation dose for ECGTF was 0.09mSv. ConclusionThis study demonstrates the feasibility of angio-IVUS co-registration which may be used as a clinical tool for localizing IVUS cross-sections along an angiographic roadmap. (c) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1077 / 1082
页数:6
相关论文
共 50 条
  • [41] Spatial Co-Registration and Spectral Concatenation of Panoramic Ground-Based Hyperspectral Images
    Okyay, Unal
    Khan, Shuhab D.
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 2018, 84 (12): : 781 - 790
  • [42] Co-registration and distortion correction of diffusion and anatomical images based on inverse contrast normalization
    Bhushan, Chitresh
    Haldar, Justin P.
    Choi, Soyoung
    Joshi, Anand A.
    Shattuck, David W.
    Leahy, Richard M.
    NEUROIMAGE, 2015, 115 : 269 - 280
  • [43] Image-based cardiac gating for three-dimensional intravascular ultrasound imaging
    Nadkarni, SK
    Boughner, D
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (01): : 53 - 63
  • [44] Co-registration of MRI and ultrasound: accuracy of targeting based on radiology-pathology correlation
    Lai, Win Shun
    Zarzour, Jessica G.
    Gordetsky, Jennifer B.
    Rais-Bahrami, Soroush
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2017, 6 (03) : 406 - 412
  • [45] CO-REGISTRATION AIRBORNE LIDAR POINT CLOUD DATA AND SYNCHRONOUS DIGITAL IMAGE REGISTRATION BASED ON COMBINED ADJUSTMENT
    Yang, Z. H.
    Zhang, Y. S.
    Zheng, T.
    Lai, W. B.
    Zou, Z. R.
    Zou, B.
    XXIII ISPRS CONGRESS, COMMISSION I, 2016, 41 (B1): : 259 - 264
  • [46] Image-based retrospective cardiac gating for three-dimensional intravascular ultrasound Imaging
    Nadkarni, SK
    Boughner, DR
    Fenster, A
    MEDICAL IMAGE 2002: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2002, 4687 : 276 - 284
  • [47] MR-PET head motion correction based on co-registration of multicontrast MR images
    Chen, Zhaolin
    Sforazzini, Francesco
    Baran, Jakub
    Close, Thomas
    Shah, Nadim Jon
    Egan, Gary F.
    HUMAN BRAIN MAPPING, 2021, 42 (13) : 4081 - 4091
  • [48] Image-based retrospective cardiac gating for 3D intravascular ultrasound (IVUS)
    Nadkaml, SK
    Boughner, D
    Fenster, A
    RADIOLOGY, 2001, 221 : 169 - 169
  • [49] Rigorous Co-Registration of KOMPSAT-3 Multispectral and Panchromatic Images for Pan-Sharpening Image Fusion
    Lee, Changno
    Oh, Jaehong
    SENSORS, 2020, 20 (07)
  • [50] NON-RIGID IMAGE REGISTRATION BASED STRAIN ESTIMATOR FOR INTRAVASCULAR ULTRASOUND ELASTOGRAPHY
    Richards, Michael S.
    Doyley, Marvin M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (03): : 515 - 533