Development of a Computerized 4-D MRI Phantom for Liver Motion Study

被引:6
|
作者
Wang, Chunhao [1 ]
Yin, Fang-Fang [1 ,2 ]
Segars, W. P. [3 ]
Chang, Zheng [1 ]
Ren, Lei [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Duke Kunshan Univ, Med Phys Grad Program, Kunshan, Jiangsu, Peoples R China
[3] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
MRI; computerized phantom; liver; organ motion; deformable registration; PHARMACOKINETIC ANALYSIS; ORGAN MOTION; XCAT; SIMULATION; THERAPY; HEAD;
D O I
10.1177/1533034617723753
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. Methods: The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom and a clinical magnetic resonance scan. Initially, the extended cardiac-torso phantom was voxelized in abdominal-chest region at the end of exhalation phase. Structures/tissues were classified into 4 categories: (1) Seven key textured organs, including liver, gallbladder, spleen, stomach, heart, kidneys, and pancreas, were mapped from a clinical T1-weighted liver magnetic resonance scan using deformable registration. (2) Large textured soft tissue volumes were simulated via an iterative pattern generation method using the same magnetic resonance scan. (3) Lung and intestine structures were generated by assigning uniform intensity with proper noise modeling. (4) Bony structures were generated by assigning the magnetic resonance values. A spherical hypointensity tumor was inserted into the liver. Other respiratory phases of the 4-dimensional phantom were generated using the backward deformation vector fields exported by the extended cardiac-torso program, except that bony structures were generated separately for each phase. A weighted image filtering process was utilized to improve the overall tissue smoothness at each phase. Results: Three 4-dimensional series with different motion amplitudes were generated. The developed motion phantom produced good illustrations of abdominal-chest region with anatomical structures in key organs and texture patterns in large soft tissue volumes. In a standard series, the tumor volume was measured as 13.90 0.11 cm(3) in a respiratory cycle and the tumor's maximum center-of-mass shift was 2.95 cm/1.84 cm on superior-inferior/anterior-posterior directions. The organ motion during the respiratory cycle was well rendered. The developed motion phantom has the flexibility of motion pattern variation, organ geometry variation, and tumor modeling variation. Conclusions: A 4-D computerized phantom was developed and could be used to produce image series with synthetic magnetic resonance textures for magnetic resonance imaging research of liver motion.
引用
收藏
页码:1051 / 1059
页数:9
相关论文
共 50 条
  • [41] A patient specific 4D MRI liver motion model based on sparse imaging and registration
    Noorda, Yolanda H.
    Bartels, Lambertus W.
    van Stralen, Marijn
    Pluim, Josien P. W.
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [42] Validation of a volumic reconstruction in 4-D echocardiography and gated spect using a dynamic cardiac phantom
    Nguyen, LD
    Léger, C
    Debrun, D
    Thérain, F
    Visser, J
    Sokole, EB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (08): : 1151 - 1160
  • [43] Design and implementation of a MRI compatible and dynamic phantom simulating the motion of a tumor in the liver under the breathing cycle
    de Merxem, Arnould Geelhand
    Lechien, Vianney
    Thibaut, Tanguy
    Dasnoy, Damien
    Macq, Benoit
    13TH INTERNATIONAL CONFERENCE ON MEDICAL INFORMATION PROCESSING AND ANALYSIS, 2017, 10572
  • [44] A comparison framework for breathing motion estimation methods from 4-d imaging
    Sarrut, David
    Delhay, Bertrand
    Villard, Pierre-Frederic
    Boldea, Vlad
    Beuve, Michael
    Clarysse, Patrick
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (12) : 1636 - 1648
  • [45] Perceptual grouping from motion cues using tensor voting in 4-D
    Nicolescu, M
    Medioni, G
    COMPUTER VISION - ECCV 2002 PT III, 2002, 2352 : 423 - 437
  • [46] AN INTRODUCTION TO 4-D DECODING METHOD OF DEVELOPMENT PROJECT REPORTS
    Anvary, Vahid Khadjeh
    Yazdi, Hamideh Karimi
    IMPLEMENTING INNOVATIVE IDEAS IN STRUCTURAL ENGINEERING AND PROJECT MANAGEMENT, 2015, : 1109 - 1114
  • [47] Determination of target motion by using a respiration monitoring mask for 4-D radiotherapy
    Lim, Sangwook
    Jeung, Tae Sig
    Park, Sung Ho
    Do Ahn, Seung
    Lee, Suk
    Kim, Chul Yong
    Yi, Byong Yong
    Lee, Sang Hoon
    Cho, Kwang Hwan
    Jang, Jisun
    Kwon, Soo Il
    Cho, Sam Ju
    Do Huh, Hyun
    Shin, Dongho
    Suh, Tae-Suk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 53 (02) : 845 - 850
  • [48] Development and applications of 4-D ultrasound (dynamic 3-D) in neurosonology
    Delcker, A
    Schürks, M
    Polz, H
    JOURNAL OF NEUROIMAGING, 1999, 9 (04) : 229 - 234
  • [49] Validating dynamic Techniques in the Radiotherapy Using a 4D-Motion phantom
    Berndt, J.
    Oechsner, M.
    Duma, M. N.
    Wilkens, J. J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 : 145 - 145
  • [50] 4-D SAR Imaging: The Case Study of Rome
    Fornaro, Gianfranco
    Serafino, Francesco
    Reale, Diego
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2010, 7 (02) : 236 - 240