Biomechanical Loading Comparison between Titanium and Bioactive Resorbable Screw Systems for Fixation of Intracapsular Condylar Head Fractures

被引:7
|
作者
Sukegawa, Shintaro [1 ,2 ]
Yamamoto, Norio [2 ]
Nakano, Keisuke [3 ]
Takabatake, Kiyofumi [3 ]
Kawai, Hotaka [3 ]
Kanno, Takahiro [4 ]
Nagatsuka, Hitoshi [3 ]
Furuki, Yoshihiko [1 ]
机构
[1] Kagawa Prefectural Cent Hosp, Dept Oral & Maxillofacial Surg, 1-2-1 Asahi Machi, Takamatsu, Kagawa 7608557, Japan
[2] Kagawa Prefectural Cent Hosp, Dept Orthopaed Surg, Takamatsu, Kagawa 600065, Japan
[3] Okayama Univ, Dept Oral Pathol & Med, Grad Sch Med Dent & Pharmaceut Sci, Okayama 7008530, Japan
[4] Shimane Univ, Dept Oral & Maxillofacial Surg, Fac Med, Matsue, Shimane 6930021, Japan
关键词
titanium screw; bioactive resorbable screw; biomechanical loading evaluation; fracture fixation; intracapsular condylar head fracture; POLY-L-LACTIDE; HYDROXYAPATITE HA PARTICLES; INTERNAL-FIXATION; FORGED COMPOSITES; BIORESORBABLE DEVICES; MANDIBULAR CONDYLE; SURGICAL-TREATMENT; OPEN REDUCTION; OSTEOSYNTHESIS; PLATE;
D O I
10.3390/ma13143153
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Osteosynthesis resorbable materials made of uncalcined and unsintered hydroxyapatite (u-HA) particles, poly-L-lactide (PLLA), are bioresorbable, and these materials have feasible bioactive/osteoconductive capacities. However, their strength and stability for fixation in mandibular condylar head fractures remain unclear. This in vitro study aimed to assess the biomechanical strength of u-HA/PLLA screws after the internal fixation of condylar head fractures. To evaluate their biomechanical behavior, 32 hemimandible replicas were divided into eight groups, each consisting of single-screw and double-screw fixations with titanium or u-HA/PLLA screws. A linear load was applied as vertical and horizontal load to each group to simulate the muscular forces in condylar head fractures. Samples were examined for 0.5, 1, 2, and 3-mm displacement loads. Two screws were needed for stable fixation of the mandibular condylar head fracture during biomechanical evaluation. After screw fixation for condylar head fractures, the titanium screws model was slightly more resistant to vertical and horizontal movement with a load for a small displacement than the u-HA/PLLA screws model. There was no statistically significant difference with load for large displacements. The u-HA/PLLA screw has a low mechanical resistance under small displacement loading compared with titanium within the limits of the mandibular head fracture model study.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Comparison of biomechanical study of sacroiliac fixation between screw with two types of washer
    Ritthiprat, Sakuna
    5TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2012), 2012, : 80 - 80
  • [42] Comparison of biomechanical study of sacroiliac fixation between screw with two types of washer
    Ritthiprat, Sakuna
    5TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2012), 2012,
  • [43] Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study
    Cift, H.
    Cetik, O.
    Kalaycioglu, B.
    Dirikoglu, M. H.
    Ozkan, K.
    Eksioglu, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (03) : 263 - 267
  • [44] Biomechanical comparison of screw versus screw-plate fixation of type 2 Schatzker fractures of the lateral tibial plateau
    Boisrenoult, P
    Bricteux, S
    Beaufils, P
    Hardy, P
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2000, 86 (07): : 707 - 711
  • [45] Screw-blade fixation systems in proximal femur fractures: a biomechanical evaluation. (8300)
    Schopper, Clemens
    Keck, Katharina
    Beeres, Frank
    Link, Bjoern-Christian
    Babst, Reto
    Nebelung, Sven
    Zderic, Ivan
    Gueorguiev, Boyko
    Knobe, Matthias
    SWISS MEDICAL WEEKLY, 2020, : S21 - S21
  • [46] Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation
    Matthias Knobe
    Simon Altgassen
    Klaus-Jürgen Maier
    Gertraud Gradl-Dietsch
    Chris Kaczmarek
    Sven Nebelung
    Kajetan Klos
    Bong-Sung Kim
    Boyko Gueorguiev
    Klemens Horst
    Benjamin Buecking
    International Orthopaedics, 2018, 42 : 409 - 418
  • [47] Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation
    Knobe, Matthias
    Altgassen, Simon
    Maier, Klaus-Jurgen
    Gradl-Dietsch, Gertraud
    Kaczmarek, Chris
    Nebelung, Sven
    Klos, Kajetan
    Kim, Bong-Sung
    Gueorguiev, Boyko
    Horst, Klemens
    Buecking, Benjamin
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (02) : 409 - 418
  • [48] A New Concept For Screw-In-Screw Fixation Of Fragility Sacrum Fractures - Biomechanical Comparison Versus Transsacral And SI Screw Fixations (8476)
    Zderic, Ivan
    Schopper, Clemens
    Lodde, Moritz
    Wagner, Daniel
    Richards, Geoff
    Gueorguiev, Boyko
    Rommens, Pol
    Acklin, Yves
    SWISS MEDICAL WEEKLY, 2020, : S37 - S38
  • [49] Influence of screw head diameter on ex vivo fixation of equine lateral condylar fractures with 5.5 mm cortical screws
    Constant, Caroline
    Zderic, Ivan
    Arens, Daniel
    Pugliese, Brenna
    Gehweiler, Dominic
    Gueorguiev-Rueegg, Boyko
    Zeiter, Stephan
    VETERINARY SURGERY, 2022, 51 (04) : 576 - 591
  • [50] Biomechanical evaluation of titanium, biodegradable plate and screw, and cyanoacrylate glue fixation systems in craniofacial surgery
    Gosain, AK
    Song, LS
    Corrao, MA
    Pintar, FA
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 101 (03) : 582 - 591