Body Composition Analysis by Air Displacement Plethysmography in Normal Weight to Extremely Obese Adults

被引:16
|
作者
Hames, Kazanna C. [1 ,2 ]
Anthony, Steven J. [2 ]
Thornton, John C. [3 ]
Gallagher, Dympna [3 ]
Goodpaster, Bret H. [2 ]
机构
[1] Univ Pittsburgh, Dept Hlth & Phys Act, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Sch Med, Pittsburgh, PA USA
[3] Columbia Univ, St Lukes Roosevelt Hosp Ctr, Coll Phys & Surg, New York Obes Nutr Res Ctr, New York, NY USA
关键词
X-RAY ABSORPTIOMETRY; VALIDATION; NONOBESE; CHILDREN; SURGERY; DENSITY; MEN;
D O I
10.1002/oby.20655
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare body composition parameters estimated by air displacement plethysmography (ADP) to dual X-ray absorptiometry (DXA) in body mass index (BMI) classifications that include extremely obese (BMI >= 40.0 kg/m (2)), and to examine if differences between analyses were influenced by BMI. Methods: Fat-free mass (FFM, kg), fat mass (FM, kg), and body fat (BF, %) were analyzed with both technologies. Results: All outcome measures of ADP and DXA were highly correlated (r >= 0.95, P < 0.001 for FFM, FM, and BF), but Bland-Altman analyses revealed significant bias (P < 0.01 for all). ADP estimated greater FFM and lower FM and BF (P < 0.01 for all). BMI explained 27% of the variance in differences between FFM measurements (P < 0.001), and 37 and 33% of the variances in differences between FM and BF measurements, respectively (P < 0.001 for both). Within normal weight and overweight classifications, ADP estimated greater FFM and lower FM and BF (P < 0.001 for all), but the opposite occurred within the extremely obese classification; ADP estimated lower FFM and greater FM and BF (P < 0.05 for all). Conclusions: Body composition analyses by the two technologies were strongly congruent, but systematically different and influenced by BMI. Caution should be taken when utilizing ADP to estimate body composition parameters over a wide range of BMI classifications that include extremely obese.
引用
收藏
页码:1078 / 1084
页数:7
相关论文
共 50 条
  • [41] Need for optimal body composition data analysis using air-displacement plethysmography in children and adolescents
    Radley, D
    Fields, DA
    JOURNAL OF NUTRITION, 2006, 136 (03): : 709 - 709
  • [42] Validity of air-displacement plethysmography in the assessment of body composition changes in a 16-month weight loss program
    Minderico, Claudia S.
    Silva, Analiza M.
    Teixeira, Pedro J.
    Sardinha, Luis B.
    Hull, Holly R.
    Fields, David A.
    NUTRITION & METABOLISM, 2006, 3 (1)
  • [43] Validity of air-displacement plethysmography in the assessment of body composition changes in a 16-month weight loss program
    Cláudia S Minderico
    Analiza M Silva
    Pedro J Teixeira
    Luis B Sardinha
    Holly R Hull
    David A Fields
    Nutrition & Metabolism, 3
  • [44] A comparison of air displacement plethysmography and bioelectrical impedance analysis in overweight and obese children
    Radley, Duncan
    Griffiths, Claire
    Cooke, Carlton
    Mackreth, Peter
    Gately, Paul
    INTERNATIONAL JOURNAL OF OBESITY, 2007, 31 : S110 - S110
  • [45] Air Displacement Plethysmography Accurately Determines Body Composition in Overweight Adults Compared to Criterion 4C Model
    Watras, Abigail C.
    Close, Rachel N.
    Clark, R. Randall
    Schoeller, Dale A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S313 - S313
  • [46] RMR Estimation Model Accuracy Using Air Displacement Plethysmography-Derived Body Composition Measures in Young Adults
    Otterstetter, Ronald
    Miller, Brian
    Fridline, Mark
    Boltz, Michelle
    Faciana, Chris
    Scanlon, Kelsey
    Mendel, Ronald
    JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2016, 35 (01) : 68 - 74
  • [47] Measurement of longitudinal changes in body composition during weight loss and maintenance in overweight and obese subjects using air-displacement plethysmography in comparison with the deuterium dilution technique
    G Plasqui
    S Soenen
    M S Westerterp-Plantenga
    K R Westerterp
    International Journal of Obesity, 2011, 35 : 1124 - 1130
  • [48] Measurement of longitudinal changes in body composition during weight loss and maintenance in overweight and obese subjects using air-displacement plethysmography in comparison with the deuterium dilution technique
    Plasqui, G.
    Soenen, S.
    Westerterp-Plantenga, M. S.
    Westerterp, K. R.
    INTERNATIONAL JOURNAL OF OBESITY, 2011, 35 (08) : 1124 - 1130
  • [49] Neonatal body composition by air displacement plethysmography in healthy term singletons: a systematic review
    Cornelia Wiechers
    Sara Kirchhof
    Christoph Maas
    Christian F. Poets
    Axel R. Franz
    BMC Pediatrics, 19
  • [50] ASSESSMENT OF BODY COMPOSITION OF KUWAITI INFANTS BY USING AIR DISPLACEMENT PLETHYSMOGRAPHY (PEA POD®)
    Al-Mesad, Y.
    Davidsson, L.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : S341 - S341