Body Composition Analysis by Air Displacement Plethysmography in Normal Weight to Extremely Obese Adults

被引:16
|
作者
Hames, Kazanna C. [1 ,2 ]
Anthony, Steven J. [2 ]
Thornton, John C. [3 ]
Gallagher, Dympna [3 ]
Goodpaster, Bret H. [2 ]
机构
[1] Univ Pittsburgh, Dept Hlth & Phys Act, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Sch Med, Pittsburgh, PA USA
[3] Columbia Univ, St Lukes Roosevelt Hosp Ctr, Coll Phys & Surg, New York Obes Nutr Res Ctr, New York, NY USA
关键词
X-RAY ABSORPTIOMETRY; VALIDATION; NONOBESE; CHILDREN; SURGERY; DENSITY; MEN;
D O I
10.1002/oby.20655
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare body composition parameters estimated by air displacement plethysmography (ADP) to dual X-ray absorptiometry (DXA) in body mass index (BMI) classifications that include extremely obese (BMI >= 40.0 kg/m (2)), and to examine if differences between analyses were influenced by BMI. Methods: Fat-free mass (FFM, kg), fat mass (FM, kg), and body fat (BF, %) were analyzed with both technologies. Results: All outcome measures of ADP and DXA were highly correlated (r >= 0.95, P < 0.001 for FFM, FM, and BF), but Bland-Altman analyses revealed significant bias (P < 0.01 for all). ADP estimated greater FFM and lower FM and BF (P < 0.01 for all). BMI explained 27% of the variance in differences between FFM measurements (P < 0.001), and 37 and 33% of the variances in differences between FM and BF measurements, respectively (P < 0.001 for both). Within normal weight and overweight classifications, ADP estimated greater FFM and lower FM and BF (P < 0.001 for all), but the opposite occurred within the extremely obese classification; ADP estimated lower FFM and greater FM and BF (P < 0.05 for all). Conclusions: Body composition analyses by the two technologies were strongly congruent, but systematically different and influenced by BMI. Caution should be taken when utilizing ADP to estimate body composition parameters over a wide range of BMI classifications that include extremely obese.
引用
收藏
页码:1078 / 1084
页数:7
相关论文
共 50 条
  • [31] Evaluation of factors determining the precision of body composition measurements by air displacement plethysmography
    Collins, AL
    McCarthy, HD
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2003, 57 (06) : 770 - 776
  • [32] The Effects Of Acute Food Consumption On Body Composition Measured By Air Displacement Plethysmography
    Otterstetter, Ronald
    Deol, Aarondeep
    Johnson, Kelly E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 799 - 799
  • [33] Statistical validation of air-displacement plethysmography for body composition assessment in children
    Ittenbach, RF
    Buison, AM
    Stallings, VA
    Zemel, BS
    ANNALS OF HUMAN BIOLOGY, 2006, 33 (02) : 187 - 201
  • [34] The Effects of Resistance Exercise on Body Composition Determination Using Air Displacement Plethysmography
    Cebrick-Grossman, Joan A.
    Deitrick, Ronald W.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 444 - 444
  • [35] Evaluation of air-displacement plethysmography for body composition assessment in preterm infants
    Paola Roggero
    Maria L. Giannì
    Orsola Amato
    Pasqua Piemontese
    Daniela Morniroli
    William W. Wong
    Fabio Mosca
    Pediatric Research, 2012, 72 : 316 - 320
  • [36] Evaluation of air-displacement plethysmography for body composition assessment in preterm infants
    Roggero, Paola
    Gianni, Maria L.
    Amato, Orsola
    Piemontese, Pasqua
    Morniroli, Daniela
    Wong, William W.
    Mosca, Fabio
    PEDIATRIC RESEARCH, 2012, 72 (03) : 316 - 320
  • [37] Air displacement plethysmography: Validation in overweight and obese subjects
    Ginde, SR
    Geliebter, A
    Rubiano, F
    Silva, AM
    Wang, J
    Heshka, S
    Heymsfield, SB
    OBESITY RESEARCH, 2005, 13 (07): : 1232 - 1237
  • [38] Air displacement plethysmography (ADP): Validation in an obese population
    Ginde, S
    Geliebter, A
    Rubiano, F
    Silva, A
    Heymsfield, S
    OBESITY RESEARCH, 2004, 12 : A136 - A136
  • [39] Comparison of Air Displacement Plethysmography and Multi-Frequency Bioelectrical Impedance Analysis for Body Composition Assessment
    Gordon, Benjamin T.
    Arikawa, Andrea Y.
    Gerkens, Kristin
    Gonzalez, Andriana
    Boyd, Sara
    Baskin, Amber
    Bednarzyk, Michele
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 907 - 907
  • [40] Need for optimal body composition data analysis using air-displacement plethysmography in children and adolescents
    Bosy-Westphal, A
    Danielzik, S
    Becker, C
    Geisler, C
    Onur, S
    Korth, O
    Bührens, F
    Müller, MJ
    JOURNAL OF NUTRITION, 2005, 135 (09): : 2257 - 2262