Analysis of liver viscosity behavior as a function of multifrequency magnetic resonance elastography (MMRE) postprocessing

被引:22
|
作者
Leclerc, Gwladys E. [1 ]
Charleux, Fabrice [2 ]
Robert, Ludovic [2 ]
Tho, Marie-Christine Ho Ba [1 ]
Rhein, Colette [3 ]
Latrive, Jean-Paul [4 ]
Bensamoun, Sabine F. [1 ]
机构
[1] Univ Technol Compiegne, CNRS, UMR BioMecan & BioIngn 7338, Compiegne, France
[2] ACRIM Polyclin St Come, Radiol Unit, Compiegne, France
[3] CH Compiegne, Unit Alcool, Compiegne, France
[4] CH Compiegne, Serv Gastroenterol & Hepatol, Compiegne, France
关键词
multifrequency magnetic resonance elastography; liver fibrosis; viscosity; elasticity; rheological models; MR ELASTOGRAPHY; HEPATIC-FIBROSIS; STIFFNESS; DIAGNOSIS;
D O I
10.1002/jmri.23986
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To analyze the relevance of the viscosity measurement as a liver diagnostic marker. Materials and Methods: To determine the level of fibrosis, a Fibroscan test was performed on 40 subjects (10 healthy volunteers and 30 patients). Subsequently, multifrequency magnetic resonance elastography (MMRE) tests were made with a pneumatic driver at 60, 70, and 80 Hz. Phase images were analyzed with two different postprocessing methods, without (Method 1) and with (Method 2) the inversion algorithm (IA), using rheological models (Voigt, springpot) in order to characterize the viscoelastic properties (viscosity: and elasticity: ). Results: MRE cartography of the viscous tendency (G(MRE_M2)) measured within the region of interest (ROI) of the liver increased as a function of the level of fibrosis. Similar results were also obtained for the viscosity ((models_M1)) calculated with a postprocessing without IA. However, the viscosity ((models_M2)) remained constant with the stage of fibrosis when the postprocessing was composed of an IA. The experimental ((MRE_M1) and G(MRE_M2)) and rheological ((models_M2) and (models_M1)) elasticities always increased with the level of fibrosis regardless of the postprocessing method. Conclusion: The variation of the liver viscosity parameter as a function of postprocessing revealed that this parameter should be further investigated to demonstrate its relevance in clinical practice. J. Magn. Reson. Imaging 2013;38:422-428. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:422 / 428
页数:7
相关论文
共 50 条
  • [1] Multifrequency Magnetic Resonance Elastography for the Assessment of Renal Allograft Function
    Garcia, Stephan Rodrigo Marticorena
    Fischer, Thomas
    Duerr, Michael
    Gueltekin, Emin
    Braun, Juergen
    Sack, Ingolf
    Guo, Jing
    INVESTIGATIVE RADIOLOGY, 2016, 51 (09) : 591 - 595
  • [2] Multifrequency inversion in magnetic resonance elastography
    Papazoglou, Sebastian
    Hirsch, Sebastian
    Braun, Juergen
    Sack, Ingolf
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (08): : 2329 - 2346
  • [3] Viscoelastic properties of liver measured by oscillatory rheometry and multifrequency magnetic resonance elastography
    Klatt, Dieter
    Friedrich, Christian
    Korth, Yasmin
    Vogt, Robert
    Braun, Juergen
    Sack, Ingolf
    BIORHEOLOGY, 2010, 47 (02) : 133 - 141
  • [4] Magnetic Resonance Elastography of Liver
    Venkatesh, Sudhakar Kundapur
    Ehman, Richard L.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2014, 22 (03) : 433 - +
  • [5] Magnetic resonance elastography of the liver
    Sack, I.
    Fischer, T.
    Thomas, A.
    Braun, J.
    RADIOLOGE, 2012, 52 (08): : 738 - +
  • [6] Reduction of breathing artifacts in multifrequency magnetic resonance elastography of the abdomen
    Shahryari, Mehrgan
    Meyer, Tom
    Warmuth, Carsten
    Herthum, Helge
    Bertalan, Gergely
    Tzschatzsch, Heiko
    Stencel, Lisa
    Lukas, Steffen
    Lilaj, Ledia
    Braun, Jurgen
    Sack, Ingolf
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 1962 - 1973
  • [7] In vivo multifrequency magnetic resonance elastography of the human intervertebral disk
    Streitberger, Kaspar-Josche
    Diederichs, Gerd
    Guo, Jing
    Fehlner, Andreas
    Hamm, Bernd
    Braun, Juergen
    Sack, Ingolf
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) : 1380 - 1387
  • [8] Optimization of a Multifrequency Magnetic Resonance Elastography Protocol for the Human Brain
    Kurt, Mehmet
    Wu, Lyndia
    Laksari, Kaveh
    Ozkaya, Efe
    Suar, Zeynep M.
    Lv, Han
    Epperson, Karla
    Epperson, Kevin
    Sawyer, Anne M.
    Camarillo, David
    Pauly, Kim Butts
    Wintermark, Max
    JOURNAL OF NEUROIMAGING, 2019, 29 (04) : 440 - 446
  • [9] Advances in Magnetic Resonance Elastography of Liver
    Li, Jiahui
    Venkatesh, Sudhakar Kundapur
    Yin, Meng
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2020, 28 (03) : 331 - +
  • [10] Magnetic resonance elastography of liver: Technique, analysis, and clinical applications
    Venkatesh, Sudhakar K.
    Yin, Meng
    Ehman, Richard L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (03) : 544 - 555