Optimization of a Multifrequency Magnetic Resonance Elastography Protocol for the Human Brain

被引:13
|
作者
Kurt, Mehmet [1 ,6 ]
Wu, Lyndia [2 ]
Laksari, Kaveh [3 ]
Ozkaya, Efe [1 ]
Suar, Zeynep M. [1 ]
Lv, Han [4 ]
Epperson, Karla [5 ]
Epperson, Kevin [5 ]
Sawyer, Anne M. [5 ]
Camarillo, David [5 ]
Pauly, Kim Butts [5 ]
Wintermark, Max [5 ]
机构
[1] Stevens Inst Technol, Dept Mech Engn, 1 Castle Point Terrace,McLean Hall,Room 525, Hoboken, NJ 07030 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[3] Univ Arizona, Dept Biomed Engn, Tucson, AZ USA
[4] Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, Beijing, Peoples R China
[5] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[6] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, New York, NY 10029 USA
关键词
Brain; viscoelasticity; multifrequency; magnetic resonance elastography; TISSUE; VISCOELASTICITY; STIFFNESS;
D O I
10.1111/jon.12619
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The brain's stiffness measurements from magnetic resonance elastography (MRE) strongly depend on actuation frequencies, which makes cross-study comparisons challenging. We performed a preliminary study to acquire optimal sets of actuation frequencies to accurately obtain rheological parameters for the whole brain (WB), white matter (WM), and gray matter (GM). METHODS: Six healthy volunteers aged between 26 and 72 years old went through MRE with a modified single-shot spin-echo echo planar imaging pulse sequence embedded with motion encoding gradients on a 3T scanner. Frequency-independent brain material properties and best-fit material model were determined from the frequency-dependent brain tissue response data (20 -80 Hz), by comparing four different linear viscoelastic material models (Maxwell, Kelvin-Voigt, Springpot, and Zener). During the material fitting, spatial averaging of complex shear moduli (G*) obtained under single actuation frequency was performed, and then rheological parameters were acquired. Since clinical scan time is limited, a combination of three actuation frequencies that would provide the most accurate approximation and lowest fitting error was determined for WB, WM, and GM by optimizing for the lowest Bayesian information criterion (BIC). RESULTS: BIC scores for the Zener and Springpot models showed these models approximate the multifrequency response of the tissue best. The best-fit frequency combinations for the reference Zener and Springpot models were identified to be 30-60-70 and 30-40-80 Hz, respectively, for the WB. CONCLUSIONS: Optimal sets of actuation frequencies to accurately obtain rheological parameters for WB, WM, and GM were determined from shear moduli measurements obtained via 3-dimensional direct inversion. We believe that our study is a first-step in developing a region-specific multifrequency MRE protocol for the human brain.
引用
收藏
页码:440 / 446
页数:7
相关论文
共 50 条
  • [1] FE Modeling of Living Human Brain Using Multifrequency Magnetic Resonance Elastography
    Naeeni, Hamed Ajabi
    Haghpanahi, Mohammad
    MECHANICAL, MATERIALS AND MANUFACTURING ENGINEERING, PTS 1-3, 2011, 66-68 : 384 - +
  • [2] Multifrequency inversion in magnetic resonance elastography
    Papazoglou, Sebastian
    Hirsch, Sebastian
    Braun, Juergen
    Sack, Ingolf
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (08): : 2329 - 2346
  • [3] In vivo multifrequency magnetic resonance elastography of the human intervertebral disk
    Streitberger, Kaspar-Josche
    Diederichs, Gerd
    Guo, Jing
    Fehlner, Andreas
    Hamm, Bernd
    Braun, Juergen
    Sack, Ingolf
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) : 1380 - 1387
  • [4] Magnetic resonance elastography of the human brain: A preliminary study
    Xu, L.
    Lin, Y.
    Xi, Z. N.
    Shen, H.
    Gao, P. Y.
    ACTA RADIOLOGICA, 2007, 48 (01) : 112 - 115
  • [5] Magnetic Resonance Elastography of the Brain
    Nanjappa, Manjunathan
    Kolipaka, Arunark
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (04) : 617 - 630
  • [6] Magnetic resonance elastography of the brain
    Kruse, Scott A.
    Rose, Gregory H.
    Glaser, Kevin J.
    Manduca, Armando
    Felmlee, Joel P.
    Jack, Clifford R., Jr.
    Ehman, Richard L.
    NEUROIMAGE, 2008, 39 (01) : 231 - 237
  • [7] Multifrequency magnetic resonance elastography of the brain reveals tissue degeneration in neuromyelitis optica spectrum disorder
    Kaspar-Josche Streitberger
    Andreas Fehlner
    Florence Pache
    Anna Lacheta
    Sebastian Papazoglou
    Judith Bellmann-Strobl
    Klemens Ruprecht
    Alexander Brandt
    Jürgen Braun
    Ingolf Sack
    Friedemann Paul
    Jens Wuerfel
    European Radiology, 2017, 27 : 2206 - 2215
  • [8] Multifrequency magnetic resonance elastography of the brain reveals tissue degeneration in neuromyelitis optica spectrum disorder
    Streitberger, Kaspar-Josche
    Fehlner, Andreas
    Pache, Florence
    Lacheta, Anna
    Papazoglou, Sebastian
    Bellmann-Strobl, Judith
    Ruprecht, Klemens
    Brandt, Alexander
    Braun, Juergen
    Sack, Ingolf
    Paul, Friedemann
    Wuerfel, Jens
    EUROPEAN RADIOLOGY, 2017, 27 (05) : 2206 - 2215
  • [9] Heterogeneous Multifrequency Direct Inversion (HMDI) for magnetic resonance elastography with application to a clinical brain exam
    Barnhill, Eric
    Davies, Penny J.
    Ariyurek, Cemre
    Fehlner, Andreas
    Braun, Juergen
    Sack, Ingolf
    MEDICAL IMAGE ANALYSIS, 2018, 46 : 180 - 188
  • [10] Reduction of breathing artifacts in multifrequency magnetic resonance elastography of the abdomen
    Shahryari, Mehrgan
    Meyer, Tom
    Warmuth, Carsten
    Herthum, Helge
    Bertalan, Gergely
    Tzschatzsch, Heiko
    Stencel, Lisa
    Lukas, Steffen
    Lilaj, Ledia
    Braun, Jurgen
    Sack, Ingolf
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 1962 - 1973