Reconstruction for 3D PET Based on Total Variation Constrained Direct Fourier Method

被引:2
|
作者
Yu, Haiqing [1 ]
Chen, Zhi [1 ]
Zhang, Heye [2 ]
Wong, Kelvin Kian Loong [3 ]
Chen, Yunmei [4 ]
Liu, Huafeng [1 ]
机构
[1] Zhejiang Univ, Dept Opt Engn, Hangzhou 310003, Zhejiang, Peoples R China
[2] Shenzhen Inst Adv Technol, Shenzhen, Guangdong, Peoples R China
[3] Univ Western Australia, Sch Comp Sci & Software Engn, Crawley, Australia
[4] Univ Florida, Dept Math, Gainesville, FL 32611 USA
来源
PLOS ONE | 2015年 / 10卷 / 09期
基金
中国国家自然科学基金;
关键词
TOTAL VARIATION REGULARIZATION; POSITRON-EMISSION-TOMOGRAPHY; WHOLE-BODY PET; IMAGE-RECONSTRUCTION; 3-D PET; ALGORITHMS; PERFORMANCE; SCANNER; ACCELERATION; SYSTEM;
D O I
10.1371/journal.pone.0138483
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presents a total variation (TV) regularized reconstruction algorithm for 3D positron emission tomography (PET). The proposed method first employs the Fourier rebinning algorithm (FORE), rebinning the 3D data into a stack of ordinary 2D data sets as sinogram data. Then, the resulted 2D sinogram are ready to be reconstructed by conventional 2D reconstruction algorithms. Given the locally piece-wise constant nature of PET images, we introduce the total variation (TV) based reconstruction schemes. More specifically, we formulate the 2D PET reconstruction problem as an optimization problem, whose objective function consists of TV norm of the reconstructed image and the data fidelity term measuring the consistency between the reconstructed image and sinogram. To solve the resulting minimization problem, we apply an efficient methods called the Bregman operator splitting algorithm with variable step size (BOSVS). Experiments based on Monte Carlo simulated data and real data are conducted as validations. The experiment results show that the proposed method produces higher accuracy than conventional direct Fourier (DF) (bias in BOSVS is 70% of ones in DF, variance of BOSVS is 80% of ones in DF).
引用
收藏
页数:21
相关论文
共 50 条
  • [31] A method of 3D reconstruction based on panoramic cameras
    Liang, Hua-Gang
    Qian, Wen-Xiu
    Liu, Yong-Kui
    Ru, Feng
    INTERNATIONAL JOURNAL OF MODELING SIMULATION AND SCIENTIFIC COMPUTING, 2015, 6 (02)
  • [32] 3D reconstruction method based on contour features
    韩宝玲
    朱颖
    罗庆生
    徐博
    张天
    Journal of Beijing Institute of Technology, 2016, 25 (03) : 301 - 308
  • [33] Fast computation of 3D Radon transform via a direct Fourier method
    Lanzavecchia, S
    Bellon, PL
    BIOINFORMATICS, 1998, 14 (02) : 212 - 216
  • [34] Artificial Evolution for 3D PET Reconstruction
    Vidal, Franck P.
    Lazaro-Ponthus, Delphine
    Legoupil, Samuel
    Louchet, Jean
    Lutton, Evelyne
    Rocchisani, Jean-Marie
    ARTIFICIAL EVOLUTION, 2010, 5975 : 37 - +
  • [35] Direct method for 3D motion estimation and depth reconstruction based on pyramid optical flow
    Zhang, Congxuan
    Chen, Zhen
    Li, Ming
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2015, 36 (05): : 1093 - 1105
  • [36] Fully 3D GPU PET reconstruction
    Herraiz, J. L.
    Espana, S.
    Cal-Gonzalez, J.
    Vaquero, J. J.
    Desco, M.
    Udias, J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S169 - S171
  • [37] PET 3D Iterative Reconstruction on Cell BE
    Chevalier, David E.
    Drapkin, Evgeny
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4054 - 4058
  • [38] Fourier rebinning for 3D transmission scans in PET
    Becher, AJ
    Karp, JS
    Matej, S
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 178P - 178P
  • [39] Constrained - Total - Variation - Minimization - Based Image Reconstruction in Breast CT
    Bian, J.
    Yang, K.
    Han, X.
    Sidky, E.
    Boone, J.
    Pan, X.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [40] A method of overlap correction for fully 3D OSEM reconstruction of PET data
    Ross, S
    Stearns, C
    Manjeshwar, R
    Iatrou, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3497 - 3500