Reconstruction for 3D PET Based on Total Variation Constrained Direct Fourier Method

被引:2
|
作者
Yu, Haiqing [1 ]
Chen, Zhi [1 ]
Zhang, Heye [2 ]
Wong, Kelvin Kian Loong [3 ]
Chen, Yunmei [4 ]
Liu, Huafeng [1 ]
机构
[1] Zhejiang Univ, Dept Opt Engn, Hangzhou 310003, Zhejiang, Peoples R China
[2] Shenzhen Inst Adv Technol, Shenzhen, Guangdong, Peoples R China
[3] Univ Western Australia, Sch Comp Sci & Software Engn, Crawley, Australia
[4] Univ Florida, Dept Math, Gainesville, FL 32611 USA
来源
PLOS ONE | 2015年 / 10卷 / 09期
基金
中国国家自然科学基金;
关键词
TOTAL VARIATION REGULARIZATION; POSITRON-EMISSION-TOMOGRAPHY; WHOLE-BODY PET; IMAGE-RECONSTRUCTION; 3-D PET; ALGORITHMS; PERFORMANCE; SCANNER; ACCELERATION; SYSTEM;
D O I
10.1371/journal.pone.0138483
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presents a total variation (TV) regularized reconstruction algorithm for 3D positron emission tomography (PET). The proposed method first employs the Fourier rebinning algorithm (FORE), rebinning the 3D data into a stack of ordinary 2D data sets as sinogram data. Then, the resulted 2D sinogram are ready to be reconstructed by conventional 2D reconstruction algorithms. Given the locally piece-wise constant nature of PET images, we introduce the total variation (TV) based reconstruction schemes. More specifically, we formulate the 2D PET reconstruction problem as an optimization problem, whose objective function consists of TV norm of the reconstructed image and the data fidelity term measuring the consistency between the reconstructed image and sinogram. To solve the resulting minimization problem, we apply an efficient methods called the Bregman operator splitting algorithm with variable step size (BOSVS). Experiments based on Monte Carlo simulated data and real data are conducted as validations. The experiment results show that the proposed method produces higher accuracy than conventional direct Fourier (DF) (bias in BOSVS is 70% of ones in DF, variance of BOSVS is 80% of ones in DF).
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Evaluation of a new gridding method for fully 3D direct Fourier PET reconstruction based on a two-plane geometry
    Ben Bouallegue, F.
    Crouzet, J. F.
    Mariano-Goulart, D.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2008, 32 (07) : 580 - 589
  • [2] A Total Variation Based Reconstruction Algorithm for 3D Ultrasound
    Afonso, Manya V.
    Sanches, Joao M. R.
    PATTERN RECOGNITION AND IMAGE ANALYSIS, IBPRIA 2013, 2013, 7887 : 149 - 156
  • [3] 3D TOF-PET image reconstruction using total variation regularization
    Raczynski, L.
    Wislicki, W.
    Klimaszewski, K.
    Krzemien, W.
    Kopka, P.
    Kowalski, P.
    Shopa, R. Y.
    Bala, M.
    Chhokar, J.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Gajewski, J.
    Gajos, A.
    Gorgol, M.
    Del Grande, R.
    Hiesmayr, B.
    Jasinska, B.
    Kacprzak, K.
    Kaplon, L.
    Kisielewska, D.
    Korcyl, G.
    Kozik, T.
    Krawczyk, N.
    Kubicz, E.
    Mohammed, M.
    Niedzwiecki, S. Z.
    Palka, M.
    Pawlik-Niedzwiecka, M.
    Raj, J.
    Rakoczy, K.
    Rucinski, A.
    Sharma, S.
    Shivani, S.
    Silarski, M.
    Skurzok, M.
    Stepien, E. L.
    Zgardzinska, B.
    Moskal, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 230 - 242
  • [4] A Direct Material Reconstruction Method for DECT Based on Total Variation and BM3D Frame
    Zhang, Wenkun
    Cai, Ailong
    Zheng, Zhizhong
    Wang, Linyuan
    Liang, Ningning
    Li, Lei
    Yan, Bin
    Hu, Guoen
    IEEE ACCESS, 2019, 7 (138579-138592) : 138579 - 138592
  • [5] 3D-FRP: Direct fourier reconstruction with Fourier reprojection for fully 3-D PET
    Matej, S
    Lewitt, RM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1378 - 1385
  • [6] Minimum total variation in 3D ultrasound reconstruction
    Sanches, J
    Bioucas-Dias, JM
    Marques, JS
    2005 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), VOLS 1-5, 2005, : 2889 - 2892
  • [7] Total Variation Based 3D Reconstruction from Monocular Laparoscopic Sequences
    Marcinczak, Jan Marek
    Grigat, Rolf-Rainer
    ABDOMINAL IMAGING: COMPUTATIONAL AND CLINICAL APPLICATIONS, 2014, 8676 : 239 - 247
  • [8] Evaluation of the direct Fourier method for 3D PET in the case of accurately determined projection data
    Li, Yingbo
    Kummert, Anton
    Li, Hongwei
    Herzog, Hans
    PROCEEDINGS OF THE EIGHTH IASTED INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING, 2006, : 162 - +
  • [9] Direct Fourier method in 3D PET using accurately determined frequency sample distribution
    Li, Yingbo
    Kummert, Anton
    Herzog, Hans
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 402 - 405
  • [10] 3D Anisotropic Total Variation method for Limited-angle CT Reconstruction
    Yang, Yao
    Li, Liang
    Chen, Zhiqiang
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,