Estimation of annual effective dose from indoor radon/thoron concentrations and measurement of radon concentrations in soil

被引:2
|
作者
Mehra, Rohit [1 ]
Bala, Pankaj [1 ]
机构
[1] Dr BR Ambedkar Natl Inst Technol, Dept Phys, Jalandhar, Punjab, India
关键词
MALWA REGION; INDIA; GAS; DWELLINGS; EXPOSURE; PUNJAB; AREAS;
D O I
10.1093/rpd/nct191
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radon short-lived decay products generated from the earth is one of the serious indoor air and soil pollutants. The RAD-7 Electronic Radon Detector with a special accessory is used for the purpose of measurement. The radon and thoron concentrations in the houses of the study area are found to vary from 350.5 to 315.25.35 Bq m(3) and 66.12.3 to 1710139.36 Bq m(3) with the average values of 98.651.9 and 388.1911 Bq m(3), respectively. From indoor air, the total annual effective dose is calculated and it varies from 0.88 to 7.94 mSv y(1). The preliminary investigation shows that the thoron concentration is higher than the radon concentration in the houses of the study area. In general, the values of the indoor air are within the recommended action level of the International Commission on Radiological Protection, 2009.
引用
下载
收藏
页码:111 / 114
页数:4
相关论文
共 50 条
  • [31] A COMPARATIVE STUDY OF DIURNAL VARIATION OF RADON AND THORON CONCENTRATIONS IN INDOOR ENVIRONMENT
    Pant, Preeti
    Kandari, Tushar
    Prasad, Mukesh
    Ramola, R. C.
    RADIATION PROTECTION DOSIMETRY, 2016, 171 (02) : 212 - 216
  • [32] GENERAL FORMULA FOR MEASUREMENT OF CONCENTRATIONS OF RADON AND THORON DAUGHTERS IN AIR
    FUCHIA, Y
    CHIAYONG, T
    HEALTH PHYSICS, 1978, 34 (05): : 501 - 503
  • [33] EFFECT OF PRESENCE OF THORON DAUGHTERS ON MEASUREMENT OF RADON DAUGHTER CONCENTRATIONS
    STRONG, JC
    DUGGAN, MJ
    HEALTH PHYSICS, 1973, 25 (03): : 299 - 300
  • [34] BASICS OF A DETECTOR FOR DIRECT MEASUREMENT OF RADON AND THORON CONCENTRATIONS IN AIR
    NOVIKOV, VM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 314 (02): : 331 - 333
  • [35] Problems with Estimating Annual Mean Indoor Radon Concentrations
    Marusiakova, Miriam
    Hulka, Jiri
    NUMERICAL ANALYSIS AND APPLIED MATHEMATICS, VOLS I-III, 2010, 1281 : 1893 - 1896
  • [36] AN OPTIMIZED SCHEME FOR MEASUREMENT OF THE CONCENTRATIONS OF THE DECAY PRODUCTS OF RADON AND THORON
    KHAN, A
    BUSIGIN, A
    PHILLIPS, CR
    HEALTH PHYSICS, 1982, 42 (06): : 809 - 826
  • [37] Dose estimation derived from the exposure to radon, thoron and their progeny in the indoor environment
    R. C. Ramola
    Mukesh Prasad
    Tushar Kandari
    Preeti Pant
    Peter Bossew
    Rosaline Mishra
    S. Tokonami
    Scientific Reports, 6
  • [38] Dose estimation derived from the exposure to radon, thoron and their progeny in the indoor environment
    Ramola, R. C.
    Prasad, Mukesh
    Kandari, Tushar
    Pant, Preeti
    Bossew, Peter
    Mishra, Rosaline
    Tokonami, S.
    SCIENTIFIC REPORTS, 2016, 6
  • [39] Measurement of radon and thoron concentrations in the indoor atmosphere and drinking water of eastern Doon valley, India
    Choubey, VM
    Bartarya, SK
    Negi, MS
    Ramola, RC
    INDOOR AND BUILT ENVIRONMENT, 2003, 12 (03) : 191 - 196
  • [40] Simultaneous measurement of radon, radon progeny and thoron concentrations using Makrofol-DE detectors
    Amgarou, K
    Font, L
    Domingo, C
    Fernández, F
    Baixeras, C
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 139 - 144