Estimation of annual effective dose from indoor radon/thoron concentrations and measurement of radon concentrations in soil

被引:2
|
作者
Mehra, Rohit [1 ]
Bala, Pankaj [1 ]
机构
[1] Dr BR Ambedkar Natl Inst Technol, Dept Phys, Jalandhar, Punjab, India
关键词
MALWA REGION; INDIA; GAS; DWELLINGS; EXPOSURE; PUNJAB; AREAS;
D O I
10.1093/rpd/nct191
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radon short-lived decay products generated from the earth is one of the serious indoor air and soil pollutants. The RAD-7 Electronic Radon Detector with a special accessory is used for the purpose of measurement. The radon and thoron concentrations in the houses of the study area are found to vary from 350.5 to 315.25.35 Bq m(3) and 66.12.3 to 1710139.36 Bq m(3) with the average values of 98.651.9 and 388.1911 Bq m(3), respectively. From indoor air, the total annual effective dose is calculated and it varies from 0.88 to 7.94 mSv y(1). The preliminary investigation shows that the thoron concentration is higher than the radon concentration in the houses of the study area. In general, the values of the indoor air are within the recommended action level of the International Commission on Radiological Protection, 2009.
引用
下载
收藏
页码:111 / 114
页数:4
相关论文
共 50 条
  • [21] Survey of Indoor concentrations of Radon and Thoron in homes in Bangalore, India
    Sathish, L. A.
    Nagaraja, K.
    Nagesh, V.
    Sundareshan, S.
    INDOOR AND BUILT ENVIRONMENT, 2011, 20 (02) : 278 - 283
  • [22] MEASUREMENT OF MIXED RADON AND THORON DAUGHTER CONCENTRATIONS IN AIR
    ZHANG, CX
    LUO, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 215 (03): : 481 - 488
  • [23] INDOOR RADON, THORON AND THEIR PROGENY CONCENTRATIONS IN HIGH THORON RURAL SERBIA ENVIRONMENTS
    Zunic, Zora S.
    Stojanovska, Z.
    Veselinovic, N.
    Mishra, R.
    Yarmoshenko, I. V.
    Sapra, B. K.
    Ishikawa, T.
    Omori, Y.
    Curguz, Z.
    Bossew, P.
    Udovicic, V.
    Ramola, R. C.
    RADIATION PROTECTION DOSIMETRY, 2017, 177 (1-2) : 36 - 39
  • [24] Measurement of indoor radon concentration and annual effective dose estimation for a university campus in Istanbul
    Osman Günay
    Serpil Aközcan
    Feride Kulalı
    Arabian Journal of Geosciences, 2019, 12
  • [25] Measurement of indoor radon concentration and annual effective dose estimation for a university campus in Istanbul
    Gunay, Osman
    Akozcan, Serpil
    Kulali, Feride
    ARABIAN JOURNAL OF GEOSCIENCES, 2019, 12 (05)
  • [26] Radiological risk estimation from indoor radon, thoron, and their progeny concentrations using nuclear track detectors
    Gogoi, Pranjal Protim
    Barooah, Debajyoti
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2022, 194 (12)
  • [27] Radiological risk estimation from indoor radon, thoron, and their progeny concentrations using nuclear track detectors
    Pranjal Protim Gogoi
    Debajyoti Barooah
    Environmental Monitoring and Assessment, 2022, 194
  • [28] Indoor radon concentrations and effective dose estimation in Al-Karkh side of Baghdad dwellings
    Amin, S. A.
    Alalgawi, S. D.
    Hashim, H. M.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY TRANSACTION A-SCIENCE, 2015, 39 (A4): : 491 - 495
  • [29] MEASUREMENT OF INDOOR RADON CONCENTRATIONS IN PUBLIC BUILDINGS
    FENYVES, EJ
    KINSLOW, RH
    HEALTH PHYSICS, 1984, 47 (01): : 204 - 204
  • [30] Indoor radon and thoron concentrations in some towns of central and South Serbia
    Vuckovic, Biljana
    Gulan, Ljiljana
    Milenkovic, Biljana
    Stajic, Jelena M.
    Milic, Gordana
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2016, 183 : 938 - 944