Validation of a Novel Wearable Electromyography Patch for Monitoring Submental Muscle Activity During Swallowing: A Randomized Crossover Trial

被引:20
|
作者
Kantarcigil, Cagla [1 ,2 ]
Kim, Min Ku [3 ]
Chang, Taehoo [4 ]
Craig, Bruce A. [5 ]
Smith, Anne [1 ]
Lee, Chi Hwan [3 ,6 ]
Malandraki, Georgia A. [1 ,3 ]
机构
[1] Purdue Univ, Dept Speech Language & Hearing Sci, W Lafayette, IN 47907 USA
[2] Northwestern Univ, Dept Commun Sci & Disorders, Evanston, IL USA
[3] Purdue Univ, Sch Biomed Engn, W Lafayette, IN 47907 USA
[4] Purdue Univ, Sch Mat Engn, W Lafayette, IN 47907 USA
[5] Purdue Univ, Dept Stat, W Lafayette, IN 47907 USA
[6] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
来源
关键词
MENDELSOHN MANEUVER; HYOID MOVEMENT; SURFACE ELECTROMYOGRAPHY; DYSPHAGIA REHABILITATION; EFFORTFUL SWALLOW; LINGUAL EXERCISE; BOLUS VOLUME; LARYNGEAL; PATTERNS; PATIENT;
D O I
10.1044/2020_JSLHR-20-00171
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Purpose: Surface electromyography (sEMG) is often used for biofeedback during swallowing rehabilitation. However, commercially available sEMG electrodes are not optimized for the head and neck area, have rigid form, and are mostly available in large medical centers. We developed an ultrathin, soft, and flexible sEMG patch, specifically designed to conform to the submental anatomy and which will be ultimately incorporated into a telehealth system. To validate this first-generation sEMG patch, we compared its safety, efficiency, and signal quality in monitoring submental muscle activity with that of widely used conventional sEMG electrodes. Method: A randomized crossover design was used to compare the experimental sEMG patch with conventional (snap-on) sEMG electrodes. Participants completed the same experimental protocol with both electrodes in counterbalanced order. Swallow trials included five trials of 5- and 10-ml water. Comparisons were made on (a) signal-related factors: signal-to-noise ratio (SNR), baseline amplitude, normalized mean amplitude, and sEMG burst duration and (b) safety/preclinical factors: safety/adverse effects, efficiency of electrode placement, and satisfaction/comfort. Noninferiority and equivalence tests were used to examine signal-related factors. Paired t tests and descriptive statistics were used to examine safety/preclinical factors. Results: Forty healthy adults participated (24 women, M-age = 67.5 years). Signal-related factors: SNR of the experimental patch was not inferior to the SNR of the conventional electrodes (p < .0056). Similarly, baseline amplitude obtained with the experimental patch was not inferior to that obtained with conventional electrodes (p < .0001). Finally, normalized amplitude values were equivalent across swallows (5 ml: p < .025; 10 ml: p < .0012), and sEMG burst duration was also equivalent (5 ml: p < .0001; 10 ml: p < .0001). Safety/preclinical factors: The experimental patch resulted in fewer mild adverse effects. Participant satisfaction was higher with the experimental patch (p = .0476, d = 0.226). Conclusions: Our new wearable sEMG patch is equivalent with widely used conventional sEMG electrodes in terms of technical performance. In addition, our patch is safe, and healthy older adults are satisfied with it. With lessons learned from the current COVID-19 pandemic, efforts to develop optimal swallowing telerehabilitation devices are more urgent than ever. Upon further validation, this new technology has the potential to improve rehabilitation and telerehabilitation efforts for patients with dysphagia. Supplemental Material: https://doi.org/10.23641/asha.12915509
引用
收藏
页码:3293 / 3310
页数:18
相关论文
共 50 条
  • [31] Effects of Exercise Compression Stockings on Anterior Muscle Compartment Pressure and Oxygenation During Running: A Randomized Crossover Trial Conducted in Healthy Recreational Runners
    Rennerfelt, Kajsa
    Lindorsson, Sophia
    Brisby, Helena
    Baranto, Adad
    Zhang, Qiuxia
    SPORTS MEDICINE, 2019, 49 (09) : 1465 - 1473
  • [32] The Efficacy of Music Therapy Protocols for Decreasing Pain, Anxiety, and Muscle Tension Levels During Burn Dressing Changes: A Prospective Randomized Crossover Trial
    Tan, Xueli
    Yowler, Charles J.
    Super, Dennis M.
    Fratianne, Richard B.
    JOURNAL OF BURN CARE & RESEARCH, 2010, 31 (04): : 590 - 597
  • [33] Effects of Exercise Compression Stockings on Anterior Muscle Compartment Pressure and Oxygenation During Running: A Randomized Crossover Trial Conducted in Healthy Recreational Runners
    Kajsa Rennerfelt
    Sophia Lindorsson
    Helena Brisby
    Adad Baranto
    Qiuxia Zhang
    Sports Medicine, 2019, 49 : 1465 - 1473
  • [34] Acute effects of electrical muscle stimulation on energy metabolism during weight-bearing exercise in young-female: a crossover randomized controlled trial
    Lee, Juseong
    Shin, Seung W.
    Kim, Junghoon
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2025,
  • [35] Effect of contingent electrical stimulation on jaw muscle activity during sleep: A pilot study with a randomized controlled trial design
    Jadidi, Faramarz
    Castrillon, Eduardo E.
    Nielsen, Patricia
    Baad-Hansen, Lene
    Svensson, Peter
    ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (05) : 1050 - 1062
  • [36] Changes in school-day step counts during a physical activity for Lent intervention: a cluster randomized crossover trial of the Savior’s Sandals
    David Kahan
    Kent A. Lorenz
    Eyad Kawwa
    Andrew Rioveros
    BMC Public Health, 19
  • [37] Changes in school-day step counts during a physical activity for Lent intervention: a cluster randomized crossover trial of the Savior's Sandals
    Kahan, David
    Lorenz, Kent A.
    Kawwa, Eyad
    Rioveros, Andrew
    BMC PUBLIC HEALTH, 2019, 19 (1)
  • [38] Normative Extensor Hallucis Brevis Muscle Activity During Locomotion Following the Development of a Novel Ultrasound-Guided Fine-Wire Electromyography Protocol
    Robb, Kelly A.
    Sutherland, Keara
    Perry, Stephen D.
    JOURNAL OF APPLIED BIOMECHANICS, 2024, 40 (06) : 477 - 483
  • [39] Prolonged slumped sitting causes neck pain and increased axioscapular muscle activity during a computer task in healthy participants-A randomized crossover study
    Christensen, Steffan Wittrup McPhee
    Palsson, Thorvaldur Skuli
    Krebs, Hans Jurgen
    Graven-Nielsen, Thomas
    Hirata, Rogerio Pessoto
    APPLIED ERGONOMICS, 2023, 110
  • [40] Practical Considerations and Successful Implementation of Vital Signs Monitoring. Comment on "Continuous Versus Intermittent Vital Signs Monitoring Using a Wearable, Wireless Patch in Patients Admitted to Surgical Wards: Pilot Cluster Randomized Controlled Trial"
    Walsh, Caoimhe
    Zargaran, David
    Patel, Nikhil
    White, Amelia
    Koumpa, Foteini Stefania
    Tanna, Ravina
    Ashraf, Muhammad Arsalan
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2021, 23 (03)