Validation of a Novel Wearable Electromyography Patch for Monitoring Submental Muscle Activity During Swallowing: A Randomized Crossover Trial

被引:20
|
作者
Kantarcigil, Cagla [1 ,2 ]
Kim, Min Ku [3 ]
Chang, Taehoo [4 ]
Craig, Bruce A. [5 ]
Smith, Anne [1 ]
Lee, Chi Hwan [3 ,6 ]
Malandraki, Georgia A. [1 ,3 ]
机构
[1] Purdue Univ, Dept Speech Language & Hearing Sci, W Lafayette, IN 47907 USA
[2] Northwestern Univ, Dept Commun Sci & Disorders, Evanston, IL USA
[3] Purdue Univ, Sch Biomed Engn, W Lafayette, IN 47907 USA
[4] Purdue Univ, Sch Mat Engn, W Lafayette, IN 47907 USA
[5] Purdue Univ, Dept Stat, W Lafayette, IN 47907 USA
[6] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
来源
关键词
MENDELSOHN MANEUVER; HYOID MOVEMENT; SURFACE ELECTROMYOGRAPHY; DYSPHAGIA REHABILITATION; EFFORTFUL SWALLOW; LINGUAL EXERCISE; BOLUS VOLUME; LARYNGEAL; PATTERNS; PATIENT;
D O I
10.1044/2020_JSLHR-20-00171
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Purpose: Surface electromyography (sEMG) is often used for biofeedback during swallowing rehabilitation. However, commercially available sEMG electrodes are not optimized for the head and neck area, have rigid form, and are mostly available in large medical centers. We developed an ultrathin, soft, and flexible sEMG patch, specifically designed to conform to the submental anatomy and which will be ultimately incorporated into a telehealth system. To validate this first-generation sEMG patch, we compared its safety, efficiency, and signal quality in monitoring submental muscle activity with that of widely used conventional sEMG electrodes. Method: A randomized crossover design was used to compare the experimental sEMG patch with conventional (snap-on) sEMG electrodes. Participants completed the same experimental protocol with both electrodes in counterbalanced order. Swallow trials included five trials of 5- and 10-ml water. Comparisons were made on (a) signal-related factors: signal-to-noise ratio (SNR), baseline amplitude, normalized mean amplitude, and sEMG burst duration and (b) safety/preclinical factors: safety/adverse effects, efficiency of electrode placement, and satisfaction/comfort. Noninferiority and equivalence tests were used to examine signal-related factors. Paired t tests and descriptive statistics were used to examine safety/preclinical factors. Results: Forty healthy adults participated (24 women, M-age = 67.5 years). Signal-related factors: SNR of the experimental patch was not inferior to the SNR of the conventional electrodes (p < .0056). Similarly, baseline amplitude obtained with the experimental patch was not inferior to that obtained with conventional electrodes (p < .0001). Finally, normalized amplitude values were equivalent across swallows (5 ml: p < .025; 10 ml: p < .0012), and sEMG burst duration was also equivalent (5 ml: p < .0001; 10 ml: p < .0001). Safety/preclinical factors: The experimental patch resulted in fewer mild adverse effects. Participant satisfaction was higher with the experimental patch (p = .0476, d = 0.226). Conclusions: Our new wearable sEMG patch is equivalent with widely used conventional sEMG electrodes in terms of technical performance. In addition, our patch is safe, and healthy older adults are satisfied with it. With lessons learned from the current COVID-19 pandemic, efforts to develop optimal swallowing telerehabilitation devices are more urgent than ever. Upon further validation, this new technology has the potential to improve rehabilitation and telerehabilitation efforts for patients with dysphagia. Supplemental Material: https://doi.org/10.23641/asha.12915509
引用
收藏
页码:3293 / 3310
页数:18
相关论文
共 50 条
  • [21] THE INFLUENCE OF HEEL HEIGHT ON MUSCLE ELECTROMYOGRAPHY OF THE LOWER EXTREMITY DURING LANDING TASKS IN RECREATIONALLY ACTIVE FEMALES: A WITHIN SUBJECTS RANDOMIZED TRIAL
    Lindenberg, Kelly M.
    Lefever, Christopher R.
    Andreyo, Kristin
    Vaughan, Ryan
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2019, 14 (06): : 866 - 876
  • [22] Continuous Versus Intermittent Vital Signs Monitoring Using a Wearable, Wireless Patch in Patients Admitted to Surgical Wards: Pilot Cluster Randomized Controlled Trial
    Downey, Candice
    Randell, Rebecca
    Brown, Julia
    Jayne, David G.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2018, 20 (12)
  • [23] Smartphones vs Wearable Devices for Remotely Monitoring Physical Activity After Hospital Discharge A Secondary Analysis of a Randomized Clinical Trial
    Patel, Mitesh S.
    Polsky, Daniel
    Kennedy, Edward H.
    Small, Dylan S.
    Evans, Chalanda N.
    Rareshide, Charles A. L.
    Volpp, Kevin G.
    JAMA NETWORK OPEN, 2020, 3 (02)
  • [24] Reliability of a wearable wireless patch for continuous remote monitoring of vital signs in patients recovering from major surgery: a clinical validation study from the TRaCINg trial
    Downey, Candice
    Ng, Shu
    Jayne, David
    Wong, David
    BMJ OPEN, 2019, 9 (08):
  • [25] A novel algorithm increases the delivery of effective cardiac resynchronization therapy during atrial fibrillation: The CRTee randomized crossover trial
    Plummer, Christopher J.
    Frank, Christopher M.
    Bari, Zsolt
    Al Hebaishi, Yahya S.
    Klepfer, Ruth Nicholson
    Stadler, Robert W.
    Ghosh, Subham
    Liu, Shufeng
    Mittal, Suneet
    HEART RHYTHM, 2018, 15 (03) : 369 - 375
  • [26] Accuracy evaluation of mainstream and sidestream end-tidal carbon dioxide monitoring during noninvasive ventilation: a randomized crossover trial (MASCAT-NIV trial)
    Sakuraya, Masaaki
    Douno, Eri
    Iwata, Wakana
    Takaba, Akihiro
    Hadama, Kosuke
    Kawamura, Natsuki
    Maezawa, Toshinori
    Iwamoto, Kei
    Yoshino, Yuya
    Yoshida, Kenichi
    JOURNAL OF INTENSIVE CARE, 2022, 10 (01)
  • [27] Accuracy evaluation of mainstream and sidestream end-tidal carbon dioxide monitoring during noninvasive ventilation: a randomized crossover trial (MASCAT-NIV trial)
    Masaaki Sakuraya
    Eri Douno
    Wakana Iwata
    Akihiro Takaba
    Kosuke Hadama
    Natsuki Kawamura
    Toshinori Maezawa
    Kei Iwamoto
    Yuya Yoshino
    Kenichi Yoshida
    Journal of Intensive Care, 10
  • [28] HRVEST: a novel data solution for using wearable smart technology to measure physiologic stress variables during a randomized clinical trial
    Gerwin, Jeffrey N.
    Almeida, Gustavo de Oliveira
    Boyce, Michael W.
    Joseph, Melissa
    Wong, Ambrose H.
    Burleson, Winslow
    Evans, Leigh V.
    FRONTIERS IN COMPUTER SCIENCE, 2024, 6
  • [29] Objective Assessment of Physical Activity at Home Using a Novel Floor-Vibration Monitoring System: Validation and Comparison With Wearable Activity Trackers and Indirect Calorimetry Measurements
    Nakajima, Yuki
    Kitayama, Asami
    Ohta, Yuji
    Motooka, Nobuhisa
    Kuno-Mizumura, Mayumi
    Miyachi, Motohiko
    Tanaka, Shigeho
    Ishikawa-Takata, Kazuko
    Tripette, Julien
    JMIR FORMATIVE RESEARCH, 2024, 8
  • [30] Validation of Fabric-Based Thigh-Wearable EMG Sensors and Oximetry for Monitoring Quadriceps Activity during Strength and Endurance Exercises
    Di Giminiani, Riccardo
    Cardinale, Marco
    Ferrari, Marco
    Quaresima, Valentina
    SENSORS, 2020, 20 (17) : 1 - 13