Validation of a Novel Wearable Electromyography Patch for Monitoring Submental Muscle Activity During Swallowing: A Randomized Crossover Trial

被引:20
|
作者
Kantarcigil, Cagla [1 ,2 ]
Kim, Min Ku [3 ]
Chang, Taehoo [4 ]
Craig, Bruce A. [5 ]
Smith, Anne [1 ]
Lee, Chi Hwan [3 ,6 ]
Malandraki, Georgia A. [1 ,3 ]
机构
[1] Purdue Univ, Dept Speech Language & Hearing Sci, W Lafayette, IN 47907 USA
[2] Northwestern Univ, Dept Commun Sci & Disorders, Evanston, IL USA
[3] Purdue Univ, Sch Biomed Engn, W Lafayette, IN 47907 USA
[4] Purdue Univ, Sch Mat Engn, W Lafayette, IN 47907 USA
[5] Purdue Univ, Dept Stat, W Lafayette, IN 47907 USA
[6] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
来源
关键词
MENDELSOHN MANEUVER; HYOID MOVEMENT; SURFACE ELECTROMYOGRAPHY; DYSPHAGIA REHABILITATION; EFFORTFUL SWALLOW; LINGUAL EXERCISE; BOLUS VOLUME; LARYNGEAL; PATTERNS; PATIENT;
D O I
10.1044/2020_JSLHR-20-00171
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Purpose: Surface electromyography (sEMG) is often used for biofeedback during swallowing rehabilitation. However, commercially available sEMG electrodes are not optimized for the head and neck area, have rigid form, and are mostly available in large medical centers. We developed an ultrathin, soft, and flexible sEMG patch, specifically designed to conform to the submental anatomy and which will be ultimately incorporated into a telehealth system. To validate this first-generation sEMG patch, we compared its safety, efficiency, and signal quality in monitoring submental muscle activity with that of widely used conventional sEMG electrodes. Method: A randomized crossover design was used to compare the experimental sEMG patch with conventional (snap-on) sEMG electrodes. Participants completed the same experimental protocol with both electrodes in counterbalanced order. Swallow trials included five trials of 5- and 10-ml water. Comparisons were made on (a) signal-related factors: signal-to-noise ratio (SNR), baseline amplitude, normalized mean amplitude, and sEMG burst duration and (b) safety/preclinical factors: safety/adverse effects, efficiency of electrode placement, and satisfaction/comfort. Noninferiority and equivalence tests were used to examine signal-related factors. Paired t tests and descriptive statistics were used to examine safety/preclinical factors. Results: Forty healthy adults participated (24 women, M-age = 67.5 years). Signal-related factors: SNR of the experimental patch was not inferior to the SNR of the conventional electrodes (p < .0056). Similarly, baseline amplitude obtained with the experimental patch was not inferior to that obtained with conventional electrodes (p < .0001). Finally, normalized amplitude values were equivalent across swallows (5 ml: p < .025; 10 ml: p < .0012), and sEMG burst duration was also equivalent (5 ml: p < .0001; 10 ml: p < .0001). Safety/preclinical factors: The experimental patch resulted in fewer mild adverse effects. Participant satisfaction was higher with the experimental patch (p = .0476, d = 0.226). Conclusions: Our new wearable sEMG patch is equivalent with widely used conventional sEMG electrodes in terms of technical performance. In addition, our patch is safe, and healthy older adults are satisfied with it. With lessons learned from the current COVID-19 pandemic, efforts to develop optimal swallowing telerehabilitation devices are more urgent than ever. Upon further validation, this new technology has the potential to improve rehabilitation and telerehabilitation efforts for patients with dysphagia. Supplemental Material: https://doi.org/10.23641/asha.12915509
引用
收藏
页码:3293 / 3310
页数:18
相关论文
共 50 条
  • [1] Submental Muscle Activity is Delayed and Shortened During Swallowing Following Stroke
    Kim, Hye-Ri
    Lee, Seung Ah
    Kim, Keewon
    Leigh, Ja-Ho
    Han, Tai Ryoon
    Oh, Byung-Mo
    PM&R, 2015, 7 (09) : 938 - 945
  • [2] Validation of a novel wearable monitoring patch for continuous respiratory monitoring
    John, M.
    Van der Westen, R. Garcia
    Yordanova, G.
    Groenendaal, W.
    Agell, C.
    John, M.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [3] Validation of mDurance, A Wearable Surface Electromyography System for Muscle Activity Assessment
    Molina-Molina, Alejandro
    Ruiz-Malagon, Emilio J.
    Carrillo-Perez, Francisco
    Roche-Seruendo, Luis E.
    Damas, Miguel
    Banos, Oresti
    Garcia-Pinillos, Felipe
    FRONTIERS IN PHYSIOLOGY, 2020, 11
  • [4] Comparison of Two Types of Electrodes for Measuring Submental Muscle Activity During Swallowing
    Ihara, Yoshiaki
    Kato, Hirotaka
    Sunakawa, Atsumi
    Murakami, Kouzou
    Minoura, Akira
    Hirano, Kojiro
    Watanabe, Yoshio
    Yoshida, Masaki
    Kokaze, Akatsuki
    Ito, Yoshinori
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [5] Effect of Muscle Deprogrammers on Muscle Activity of Masseter and Temporalis Muscles Using Surface Electromyography: A Randomized Crossover Clinical Study
    Gaikwad, Amit M.
    Nadgere, Jyoti B.
    Tamore, Shraddha H.
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2022, 14 (01): : 26 - 33
  • [6] The Effect of the Nordic Hamstring Exercise on Muscle Activity: A Multichannel Electromyography Randomized Controlled Trial
    Suskens, Jozef J. M.
    Maas, Huub
    van Dieen, Jaap H.
    Kerkhoffs, Gino M. M. J.
    Goedhart, Edwin A.
    Tol, Johannes L.
    Reurink, Gustaaf
    JOURNAL OF APPLIED BIOMECHANICS, 2023, 39 (06) : 377 - 387
  • [7] Surface electromyograph activity of submental muscles during swallowing and expiratory muscle training tasks in Huntington's disease patients
    Reyes, Alvaro
    Cruickshank, Travis
    Thompson, Jennifer
    Ziman, Mel
    Nosaka, Kazunori
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2014, 24 (01) : 153 - 158
  • [8] KINO-CARDIOGRAPHY, A NEW WEARABLE MONITORING TECHNIQUE: A RANDOMIZED DOUBLE-BLIND CROSSOVER VALIDATION WITH ECHOCARDIOGRAPHY
    Hossein, A.
    Mirica, D. Corina
    Del Rio, I. Juarez
    Gorlier, D.
    Monfils, J.
    Nonclercq, A.
    Migeotte, P. F.
    van de Borne, P.
    JOURNAL OF HYPERTENSION, 2018, 36 : E219 - E219
  • [9] Basic Characteristics of Submental Mechanomyography and Electromyography Measured Simultaneously During Tongue Lift Using a Novel Muscle Function Measurement Device
    Shinichi Fukuhara
    Masahiro Ikeno
    Hisao Oka
    Journal of Medical and Biological Engineering, 2023, 43 : 612 - 622
  • [10] Basic Characteristics of Submental Mechanomyography and Electromyography Measured Simultaneously During Tongue Lift Using a Novel Muscle Function Measurement Device
    Fukuhara, Shinichi
    Ikeno, Masahiro
    Oka, Hisao
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2023, 43 (05) : 612 - 622