Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points

被引:250
|
作者
Santos-Lozano, A. [1 ,2 ]
Santin-Medeiros, F. [2 ]
Cardon, G. [3 ]
Torres-Luque, G. [4 ]
Bailon, R. [5 ,6 ]
Bergmeir, C. [7 ]
Ruiz, J. R. [8 ]
Lucia, A. [9 ]
Garatachea, N. [2 ]
机构
[1] Univ Leon, Fac Hlth Sci, Dept Biomed Sci, E-24071 Leon, Spain
[2] Univ Zaragoza, Dept Physiote & Nursing, Huesca 22001, Spain
[3] Univ Ghent, Dept Movement & Sports Sci, B-9000 Ghent, Belgium
[4] Univ Jaen, Fac Sci Educ, Jaen, Spain
[5] Univ Zaragoza, IIS Aragon, Aragon Inst Engn Res I3A, E-50009 Zaragoza, Spain
[6] CIBER Bioingn Biomat & Nanomed CIBER BBN, Madrid, Spain
[7] Univ Granada, ETS Ingn Informat & Telecomunicac, Dept Comp Sci & Artificial Intelligence, E-18071 Granada, Spain
[8] Univ Granada, E-18071 Granada, Spain
[9] Univ Europea Madrid, Madrid, Spain
关键词
activity monitor; physical activity intensity; energy expenditure; ESTIMATING ENERGY-EXPENDITURE; ACTIVITY MONITORS; TRIAXIAL ACCELEROMETER; 2-REGRESSION MODEL; OLDER-ADULTS; ACTICAL ACCELEROMETER; CALIBRATION; CHILDREN; MODERATE; OUTPUT;
D O I
10.1055/s-0033-1337945
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aims of this study were: to compare energy expenditure (EE) estimated from the existing GT3X accelerometer equations and EE measured with indirect calorimetry; to define new equations for EE estimation with the GT3X in youth, adults and older people; and to define GT3X vector magnitude (VM) cut points allowing to classify PA intensity in the aforementioned age-groups. The study comprised 31 youth, 31 adults and 35 older people. Participants wore the GT3X (setup: 1-s epoch) over their right hip during 6 conditions of 10-min duration each: resting, treadmill walking/running at 3,5,7, and 9km<bold></bold>h(-1), and repeated sit-stands (30times<bold></bold>min(-1)). The GT3X proved to be a good tool to predict EE in youth and adults (able to discriminate between the aforementioned conditions), but not in the elderly. We defined the following equations: for all age-groups combined, EE (METs)=2.7406+0.00056<bold></bold>VM activity counts (counts<bold></bold>min(-1))-0.008542<bold></bold>age (years)-0.01380<bold></bold> body mass (kg); for youth, METs=1.546618+0.000658<bold></bold>VM activity counts (counts<bold></bold>min(-1)); for adults, METs=2.8323+0.00054<bold></bold>VM activity counts (counts<bold></bold>min(-1))-0.059123<bold></bold>body mass (kg)+1.4410<bold></bold>gender (women=1, men=2); and for the elderly, METs=2.5878+0.00047<bold></bold>VM activity counts (counts<bold></bold>min(-1))-0.6453<bold></bold>gender (women=1, men=2). Activity counts derived from the VM yielded a more accurate EE estimation than those derived from the Y-axis. The GT3X represents a step forward in triaxial technology estimating EE. However, age-specific equations must be used to ensure the correct use of this device.
引用
收藏
页码:975 / 982
页数:8
相关论文
共 50 条
  • [21] Measuring reliability and validity of the ActiGraph GT3X accelerometer for children with cerebral palsy: A feasibility study
    O'Neil, Margaret E.
    Fragala-Pinkham, Maria A.
    Forman, Jeffrey L.
    Trost, Stewart G.
    JOURNAL OF PEDIATRIC REHABILITATION MEDICINE, 2014, 7 (03) : 233 - 240
  • [22] Google fit smartphone application or Gt3X Actigraph: Which is better for detecting the stepping activity of individuals with stroke? A validity study
    Polese, Janaine Cunha
    Silva e Faria, Giselle
    Ribeiro-Samora, Giane Amorim
    Lima, Lorena Pereira
    Coelho de Morais Faria, Christina Danielli
    Scianni, Aline Alvim
    Teixeira-Salmela, Luci Fuscaldi
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2019, 23 (03) : 461 - 465
  • [23] A comparison of the Actigraph GT1M and GT3X accelerometers under standardized and free-living conditions
    Kaminsky, Leonard A.
    Ozemek, Cemal
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (11) : 1869 - 1876
  • [24] Validation of the use of Actigraph GT3X accelerometers to estimate energy expenditure in full time manual wheelchair users with spinal cord injury
    X García-Massó
    P Serra-Añó
    L M García-Raffi
    E A Sánchez-Pérez
    J López-Pascual
    L M Gonzalez
    Spinal Cord, 2013, 51 : 898 - 903
  • [25] Accuracy of inclinometer functions of the activPAL and ActiGraph GT3X+: A focus on physical activity
    An, Hyun-Sung
    Kim, Youngwon
    Lee, Jung-Min
    GAIT & POSTURE, 2017, 51 : 174 - 180
  • [26] Validation of the use of Actigraph GT3X accelerometers to estimate energy expenditure in full time manual wheelchair users with spinal cord injury
    Garcia-Masso, X.
    Serra-Ano, P.
    Garcia-Raffi, L. M.
    Sanchez-Perez, E. A.
    Lopez-Pascual, J.
    Gonzalez, L. M.
    SPINAL CORD, 2013, 51 (12) : 898 - 903
  • [27] Validation of actiGraph GT3X accelerometers in collagen 6-related muscular dystrophy and LAMA2-related muscular dystrophy
    Meilleur, K.
    Elliott, J.
    Linton, M.
    Vuillerot, C.
    Bendixen, R.
    Arveson, I.
    Tounkara, E.
    Waite, M.
    Nichols, C.
    Yang, K.
    Donkervoort, S.
    Dastgir, J.
    Leach, M.
    Boennemann, C.
    Jain, M.
    NEUROMUSCULAR DISORDERS, 2015, 25 : S265 - S266
  • [28] Actigraph Cut-Points for Sedentary Behaviour and Moderate-to-Vigorous Intensity Physical Activity in 2-3 Year Old Children
    Costa, Silvia S. N.
    Clemes, Stacy A.
    Barber, Sally
    Griffiths, Paula
    Cameron, Noel
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 662 - 662
  • [29] Validating The Garmin Vivosmart Hr Vs The Actigraph Gt3x Accelerometer In Measuring Energy Expenditure.
    Hayes, Ethan
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 662 - 662
  • [30] Intermonitor Variability of GT3X Accelerometer
    Santos-Lozano, A.
    Torres-Luque, G.
    Marin, P. J.
    Ruiz, J. R.
    Lucia, A.
    Garatachea, N.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2012, 33 (12) : 994 - 999