Posterior Glenoid Wear in Total Shoulder Arthroplasty: Eccentric Anterior Reaming Is Superior to Posterior Augment

被引:26
|
作者
Wang, Tim [1 ]
Abrams, Geoffrey D. [1 ,2 ]
Behn, Anthony W. [1 ]
Lindsey, Derek [2 ]
Giori, Nicholas [2 ]
Cheung, Emilie V. [1 ]
机构
[1] Stanford Univ, Dept Orthopaed Surg, Redwood City, CA 94063 USA
[2] Vet Affairs Palo Alto Hlth Care Syst, Ctr Tissue Regenerat Repair & Restorat, Palo Alto, CA USA
关键词
TOTAL KNEE ARTHROPLASTY; BONE DEFICIENCY; WEDGE AUGMENTATION; COMPONENTS; EROSION; OSTEOARTHRITIS; RETROVERSION; MANAGEMENT; FIXATION; DESIGN;
D O I
10.1007/s11999-015-4482-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Uncorrected glenoid retroversion during total shoulder arthroplasty may lead to an increased likelihood of glenoid prosthetic loosening. Augmented glenoid components seek to correct retroversion to address posterior glenoid bone loss, but few biomechanical studies have evaluated their performance. Questions/purposes We compared the use of augmented glenoid components with eccentric reaming with standard glenoid components in a posterior glenoid wear model. The primary outcome for biomechanical stability in this model was assessed by (1) implant edge displacement in superior and inferior edge loading at intervals up to 100,000 cycles, with secondary outcomes including (2) implant edge load during superior and inferior translation at intervals up to 100,000 cycles, and (3) incidence of glenoid fracture during implant preparation and after cyclic loading. Methods A 12A degrees-posterior glenoid defect was created in 12 composite scapulae, and the specimens were divided in two equal groups. In the posterior augment group, glenoid version was corrected to 8A degrees and an 8A degrees-augmented polyethylene glenoid component was placed. In the eccentric reaming group, anterior glenoid reaming was performed to neutral version and a standard polyethylene glenoid component was placed. Specimens were cyclically loaded in the superoinferior direction to 100,000 cycles. Superior and inferior glenoid edge displacements were recorded. Results Surviving specimens in the posterior augment group showed greater displacement than the eccentric reaming group of superior (1.01 +/- 0.02 [95% CI, 0.89-1.13] versus 0.83 +/- 0.10 [95% CI, 0.72-0.94 mm]; mean difference, 0.18 mm; p = 0.025) and inferior markers (1.36 +/- 0.05 [95% CI, 1.24-1.48] versus 1.20 +/- 0.09 [95% CI, 1.09-1.32 mm]; mean difference, 0.16 mm; p = 0.038) during superior edge loading and greater displacement of the superior marker during inferior edge loading (1.44 +/- 0.06 [95% CI, 1.28-1.59] versus 1.16 +/- 0.11 [95% CI, 1.02-1.30 mm]; mean difference, 0.28 mm; p = 0.009) at 100,000 cycles. No difference was seen with the inferior marker during inferior edge loading (0.93 +/- 0.15 [95% CI, 0.56-1.29] versus 0.78 +/- 0.06 [95% CI, 0.70-0.85 mm]; mean difference, 0.15 mm; p = 0.079). No differences in implant edge load were seen during superior and inferior loading. There were no instances of glenoid vault fracture in either group during implant preparation; however, a greater number of specimens in the eccentric reaming group were able to achieve the final 100,000 time without catastrophic fracture than those in the posterior augment group. Conclusions When addressing posterior glenoid wear in surrogate scapula models, use of angle-backed augmented glenoid components results in accelerated implant loosening compared with neutral-version glenoid after eccentric reaming, as shown by increased implant edge displacement at analogous times.
引用
收藏
页码:3928 / 3936
页数:9
相关论文
共 50 条
  • [1] CORR Insights®: Posterior Glenoid Wear in Total Shoulder Arthroplasty: Eccentric Anterior Reaming Is Superior to Posterior Augment
    Gutierrez, Sergio
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (12) : 3937 - 3939
  • [2] Posterior glenoid bone grafting in total shoulder arthroplasty for osteoarthritis with severe posterior glenoid wear
    Nicholson, Gregory P.
    Cvetanovich, Gregory L.
    Rao, Allison J.
    O'Donnell, Patrick
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (10) : 1844 - 1853
  • [3] Biomechanical Impact of Posterior Glenoid Wear on Anatomic Total Shoulder Arthroplasty
    Roche, Christopher P.
    Diep, Phong
    Grey, Sean G.
    Flurin, Pierre-Henri
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2013, 71 : S5 - S11
  • [4] Complications of shoulder arthroplasty for osteoarthritis with posterior glenoid wear
    Gallusser, N.
    Farron, A.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (05) : 503 - 508
  • [5] Vault perforation after eccentric glenoid reaming for deformity correction in anatomic total shoulder arthroplasty
    Olszewski, Adam
    Ramme, Austin J.
    Maerz, Tristan
    Freehill, Michael T.
    Warner, Jon J. P.
    Bedi, Asheesh
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (07) : 1450 - 1459
  • [6] How to deal with posterior glenoid erosion in anatomic total shoulder arthroplasty
    Albers, Sebastian
    Hudek, Robert
    Kircher, Joern
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2022, 17 (02): : 74 - 83
  • [7] Shoulder Arthroplasty in the Presence of Posterior Glenoid Bone Loss
    Stephens, Scott P.
    Paisley, Kevin C.
    Jeng, Jeffrey
    Dutta, Anil K.
    Wirth, Michael A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (03): : 251 - 259
  • [8] Glenoid morphology after reaming in computer-simulated total shoulder arthroplasty
    Yongpravat, Charlie
    Lester, Jonathan D.
    Saifi, Comron
    Trubelja, Alen
    Greiwe, R. Michael
    Bigliani, Louis U.
    Levine, William N.
    Gardner, Thomas R.
    Ahmad, Christopher S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (01) : 122 - 128
  • [9] Glenoid subchondral bone density distribution in male total shoulder arthroplasty subjects with eccentric and concentric wear
    Simon, Peter
    Gupta, Anil
    Pappou, Ioannis
    Hussey, Michael M.
    Santoni, Brandon G.
    Inoue, Nozomu
    Frankle, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (03) : 416 - 424
  • [10] Outcomes of Posterior Glenoid Bone-Grafting in Anatomical Total Shoulder Arthroplasty A Systematic Review
    Gates, Stephen
    Cutler, Holt
    Khazzam, Michael
    JBJS REVIEWS, 2019, 7 (09)