IMPACT OF PRECONDITIONING PULSE ON LESION FORMATION DURING HIGH-INTENSITY FOCUSED ULTRASOUND HISTOTRIPSY

被引:15
|
作者
Xu, Jin [2 ]
Bigelow, Timothy A. [1 ,2 ]
Riesberg, Grant M. [1 ]
机构
[1] Iowa State Univ, Dept Elect & Comp Engn, Ames, IA 50011 USA
[2] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2012年 / 38卷 / 11期
基金
美国国家科学基金会;
关键词
Histotripsy; HIFU; Cavitation; Mechanical effect; Thermal effect; TISSUE EROSION; CAVITATIONAL THERAPY; BACKSCATTER; TIME; INTERFACE; CANCER; TUMOR;
D O I
10.1016/j.ultrasmedbio.2012.06.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Therapeutic applications with high-intensity focused ultrasound (HIFU) fall into two classifications-one using thermal effect for coagulation or ablation while generally avoiding cavitation and the other using cavitation-mediated mechanical effects while suppressing heating. Representative of the latter, histotripsy uses HIFU at low duty factor to create energetic bubble clouds inside tissue to liquefy a region and has the advantages in real-time monitoring and lesion fidelity to treatment planning. We explored the impact of a preconditioning/ heating pulse on histotripsy lesion formation in porcine muscle samples. During sonication, a targeted square region 9 mm wide (lateral to the focal plane) was scanned in a raster pattern with a step size of 0.75 mm. The 20-s exposure at each treatment location consisted of a 5-s duration preconditioning burst at spatial-peak intensities from 0-1386 W/cm(2) followed by 5000 tone bursts at high intensity (with spatial-peak pulse-average intensity of 47.34 kW/cm(2), spatial-peak temporal-average intensity of 284 W/cm(2), peak compressional pressure of 102 MPa and peak rarefactional pressure of 17 MPa). The temperature increase for all exposures was measured using a thermal imager immediately after each exposure. Lesion volume increased with increasing amplitude of the preconditioning pulse until coagulation was observed, but lesion width/area did not change significantly with the amplitude. In addition, the lesion dimensions became smaller when the global tissue temperature was raised before applying the histotripsy pulsing sequence. Therefore, the benefit of the preconditioning pulse was not caused by global heating. (E-mail: bigelow@iastate.edu) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1918 / 1929
页数:12
相关论文
共 50 条
  • [41] Hyperecho in ultrasound images during high-intensity focused ultrasound ablation for hepatocellular carcinomas
    Fukuda, Hiroyuki
    Numata, Kazushi
    Nozaki, Akito
    Kondo, Masaaki
    Morimoto, Manabu
    Tanaka, Katsuaki
    Ito, Ryu
    Ohto, Masao
    Ishibashi, Yoshiharu
    Oshima, Noriyoshi
    Ito, Ayao
    Zhu, Hui
    Wang, Zhi-Biao
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E571 - E575
  • [42] HIGH-FREQUENCY ULTRASOUND M-MODE IMAGING FOR IDENTIFYING LESION AND BUBBLE ACTIVITY DURING HIGH-INTENSITY FOCUSED ULTRASOUND ABLATION
    Kumon, Ronald E.
    Gudur, Madhu S. R.
    Zhou, Yun
    Deng, Cheri X.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (04): : 626 - 641
  • [43] Boiling histotripsy lesion characterization on a clinical magnetic resonance imaging-guided high intensity focused ultrasound system
    Eranki, Avinash
    Farr, Navid
    Partanen, Ari
    Sharma, Karun V.
    Chen, Hong
    Rossi, Christopher T.
    Kothapalli, Satya V. V. N.
    Oetgen, Matthew
    Kim, AeRang
    Negussie, Ayele H.
    Woods, David
    Wood, Bradford J.
    Kim, Peter C. W.
    Yarmolenko, Pavel S.
    PLOS ONE, 2017, 12 (03):
  • [44] Enhancement of High-Intensity Focused Ultrasound Heating by Short-Pulse Generated Cavitation
    Yoshizawa, Shin
    Takagi, Ryo
    Umemura, Shin-ichiro
    APPLIED SCIENCES-BASEL, 2017, 7 (03):
  • [45] Ultrasound-Guided Mechanical High-Intensity Focused Ultrasound (Histotripsy) Through an Acoustically Permeable Polyolefin-Based Cranioplasty Device
    Ruger, Lauren
    Langman, Maya
    Farrell, Renata
    Rossmeisl, John H.
    Prada, Francesco
    Vlaisavljevich, Eli
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (10) : 2877 - 2888
  • [46] Intensification of the impact of high-intensity focused ultrasound (HIFU) with special spatiotemporal modulation
    V. A. Gusev
    O. V. Rudenko
    Acoustical Physics, 2013, 59 : 45 - 50
  • [47] The urodynamic impact of transrectal high-intensity focused ultrasound on bladder outflow obstruction
    Madersbacher, S
    Klingler, C
    Schatzl, G
    Schmidbauer, CP
    Marberger, M
    EUROPEAN UROLOGY, 1996, 30 (04) : 437 - 445
  • [48] Intensification of the impact of high-intensity focused ultrasound (HIFU) with special spatiotemporal modulation
    Gusev, V. A.
    Rudenko, O. V.
    ACOUSTICAL PHYSICS, 2013, 59 (01) : 45 - 50
  • [49] Monitoring of high-intensity focused ultrasound lesion formation using decorrelation between high-speed ultrasonic images by parallel beamforming
    Sasaki, Shoya
    Takagi, Ryo
    Matsuura, Keiko
    Yoshizawa, Shin
    Umemura, Shin-ichiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (07)
  • [50] Monitoring of high-Intensity focused ultrasound lesion formation using decorrelation between high-speed ultrasonic images by parallel beamforming
    Sasaki, Shoya
    Takagi, Ryo
    Matsuura, Keiko
    Yoshizawa, Shin
    Umemura, Shin-Ichiro
    Japanese Journal of Applied Physics, 2014, 53 (7 SPEC. ISSUE)