IMPACT OF PRECONDITIONING PULSE ON LESION FORMATION DURING HIGH-INTENSITY FOCUSED ULTRASOUND HISTOTRIPSY

被引:15
|
作者
Xu, Jin [2 ]
Bigelow, Timothy A. [1 ,2 ]
Riesberg, Grant M. [1 ]
机构
[1] Iowa State Univ, Dept Elect & Comp Engn, Ames, IA 50011 USA
[2] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2012年 / 38卷 / 11期
基金
美国国家科学基金会;
关键词
Histotripsy; HIFU; Cavitation; Mechanical effect; Thermal effect; TISSUE EROSION; CAVITATIONAL THERAPY; BACKSCATTER; TIME; INTERFACE; CANCER; TUMOR;
D O I
10.1016/j.ultrasmedbio.2012.06.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Therapeutic applications with high-intensity focused ultrasound (HIFU) fall into two classifications-one using thermal effect for coagulation or ablation while generally avoiding cavitation and the other using cavitation-mediated mechanical effects while suppressing heating. Representative of the latter, histotripsy uses HIFU at low duty factor to create energetic bubble clouds inside tissue to liquefy a region and has the advantages in real-time monitoring and lesion fidelity to treatment planning. We explored the impact of a preconditioning/ heating pulse on histotripsy lesion formation in porcine muscle samples. During sonication, a targeted square region 9 mm wide (lateral to the focal plane) was scanned in a raster pattern with a step size of 0.75 mm. The 20-s exposure at each treatment location consisted of a 5-s duration preconditioning burst at spatial-peak intensities from 0-1386 W/cm(2) followed by 5000 tone bursts at high intensity (with spatial-peak pulse-average intensity of 47.34 kW/cm(2), spatial-peak temporal-average intensity of 284 W/cm(2), peak compressional pressure of 102 MPa and peak rarefactional pressure of 17 MPa). The temperature increase for all exposures was measured using a thermal imager immediately after each exposure. Lesion volume increased with increasing amplitude of the preconditioning pulse until coagulation was observed, but lesion width/area did not change significantly with the amplitude. In addition, the lesion dimensions became smaller when the global tissue temperature was raised before applying the histotripsy pulsing sequence. Therefore, the benefit of the preconditioning pulse was not caused by global heating. (E-mail: bigelow@iastate.edu) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1918 / 1929
页数:12
相关论文
共 50 条
  • [21] THE EFFECT OF THE SCANNING PATHWAY IN HIGH-INTENSITY FOCUSED ULTRASOUND THERAPY ON LESION PRODUCTION
    Zhou, Yufeng
    Kargl, Steven G.
    Hwang, Joo Ha
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (09): : 1457 - 1468
  • [22] Influence of ablated tissue on the formation of high-intensity focused ultrasound lesions
    Chen, LL
    terHaar, G
    Hill, CR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06): : 921 - 931
  • [23] Effect of pulse repetition frequency of high-intensity focused ultrasound on in vitro thrombolysis
    Yang, Wenjing
    Zhou, Yufeng
    ULTRASONICS SONOCHEMISTRY, 2017, 35 : 152 - 160
  • [24] Strategy of High Efficiency and Refined High-intensity Focused Ultrasound and Ultrasound Monitoring Imaging of Thermal Lesion and Cavitation
    Wan, Mingxi
    Zhang, Siyuan
    Lu, Mingzhu
    Hu, Hong
    Jing, Bowen
    Liu, Runna
    Zhong, Hui
    PROCEEDINGS FROM THE 14TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2017, 1821
  • [25] Dependence of ablative ability of high-intensity focused ultrasound cavitation-based histotripsy on mechanical properties of agar
    Xu, Jin
    Bigelow, Timothy A.
    Davis, Gabriel
    Avendano, Alex
    Shrotriya, Pranav
    Bergler, Kevin
    Hu, Zhong
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2014, 136 (06): : 3018 - 3027
  • [26] Expulsion of Adenomyotic Lesion into Uterine Cavity after High-intensity Focused Ultrasound Ablation
    Chen, Hengxi
    Tan, Xin
    Xiong, Wei
    Xie, Yanhong
    Wang, Xiaoli
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2022, 29 (11) : 1214 - 1215
  • [27] Toward high-intensity focused ultrasound lesion quantification using compressive sensing theory
    Ghasemifard, Hadi
    Behnam, Hamid
    Tavakkoli, Jahan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (12) : 1152 - 1164
  • [28] Evaluate Thermal Lesion Using Nakagami Imaging for Monitoring of High-Intensity Focused Ultrasound
    Zhang, Siyuan
    Li, Chong
    Zhou, Fanyu
    Wang, Supin
    Wan, Mingxi
    PROCEEDINGS FROM THE 13TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2017, 1816
  • [29] TREATMENT OF GLAUCOMA WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    VALTOT, F
    KOPEL, J
    HAUT, J
    INTERNATIONAL OPHTHALMOLOGY, 1989, 13 (1-2) : 167 - 170
  • [30] An early history of high-intensity focused ultrasound
    O'Brien, William D., Jr.
    Dunn, Floyd
    PHYSICS TODAY, 2015, 68 (10) : 40 - 45