IMPACT OF PRECONDITIONING PULSE ON LESION FORMATION DURING HIGH-INTENSITY FOCUSED ULTRASOUND HISTOTRIPSY

被引:15
|
作者
Xu, Jin [2 ]
Bigelow, Timothy A. [1 ,2 ]
Riesberg, Grant M. [1 ]
机构
[1] Iowa State Univ, Dept Elect & Comp Engn, Ames, IA 50011 USA
[2] Iowa State Univ, Dept Mech Engn, Ames, IA 50011 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2012年 / 38卷 / 11期
基金
美国国家科学基金会;
关键词
Histotripsy; HIFU; Cavitation; Mechanical effect; Thermal effect; TISSUE EROSION; CAVITATIONAL THERAPY; BACKSCATTER; TIME; INTERFACE; CANCER; TUMOR;
D O I
10.1016/j.ultrasmedbio.2012.06.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Therapeutic applications with high-intensity focused ultrasound (HIFU) fall into two classifications-one using thermal effect for coagulation or ablation while generally avoiding cavitation and the other using cavitation-mediated mechanical effects while suppressing heating. Representative of the latter, histotripsy uses HIFU at low duty factor to create energetic bubble clouds inside tissue to liquefy a region and has the advantages in real-time monitoring and lesion fidelity to treatment planning. We explored the impact of a preconditioning/ heating pulse on histotripsy lesion formation in porcine muscle samples. During sonication, a targeted square region 9 mm wide (lateral to the focal plane) was scanned in a raster pattern with a step size of 0.75 mm. The 20-s exposure at each treatment location consisted of a 5-s duration preconditioning burst at spatial-peak intensities from 0-1386 W/cm(2) followed by 5000 tone bursts at high intensity (with spatial-peak pulse-average intensity of 47.34 kW/cm(2), spatial-peak temporal-average intensity of 284 W/cm(2), peak compressional pressure of 102 MPa and peak rarefactional pressure of 17 MPa). The temperature increase for all exposures was measured using a thermal imager immediately after each exposure. Lesion volume increased with increasing amplitude of the preconditioning pulse until coagulation was observed, but lesion width/area did not change significantly with the amplitude. In addition, the lesion dimensions became smaller when the global tissue temperature was raised before applying the histotripsy pulsing sequence. Therefore, the benefit of the preconditioning pulse was not caused by global heating. (E-mail: bigelow@iastate.edu) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1918 / 1929
页数:12
相关论文
共 50 条
  • [1] Temperature rise recorded during lesion formation by high-intensity focused ultrasound
    Clarke, RL
    terHaar, GR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02): : 299 - 306
  • [2] Temperature rise recorded during lesion formation by high-intensity focused ultrasound
    Institute of Cancer Research, Sutton, Surrey, United Kingdom
    ULTRASOUND MED. BIOL., 2 (299-306):
  • [3] Myocardial lesion formation using high-intensity focused ultrasound
    Engel, David J.
    Muratore, Robert
    Hirata, Kumiko
    Otsuka, Ryo
    Fujikura, Kana
    Sugioka, Kenichi
    Marboe, Charles
    Lizzi, Frederic L.
    Homma, Shunichi
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (07) : 932 - 937
  • [4] Variations of bubble cavitation and temperature elevation during lesion formation by high-intensity focused ultrasound
    Zhou, Yufeng
    Gao, Xiaobin Wilson
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 134 (02): : 1683 - 1694
  • [5] Variations of bubble cavitation and temperature elevation during lesion formation by high-intensity focused ultrasound
    Zhou, Y. (yfzhou@ntu.edu.sg), 1683, Acoustical Society of America (134):
  • [6] Impact of cavitation on lesion formation induced by high intensity focused ultrasound
    Fan, Pengfei
    Yu, Jie
    Yang, Xin
    Tu, Juan
    Guo, Xiasheng
    Huang, Pintong
    Zhang, Dong
    CHINESE PHYSICS B, 2017, 26 (05)
  • [7] Impact of cavitation on lesion formation induced by high intensity focused ultrasound
    范鹏飞
    于洁
    杨鑫
    屠娟
    郭霞生
    黄品同
    章东
    Chinese Physics B, 2017, 26 (05) : 239 - 246
  • [8] Precision Control of Lesions by High-Intensity Focused Ultrasound Cavitation-Based Histotripsy Through Varying Pulse Duration
    Xu, Jin
    Bigelow, Timothy A.
    Nagaraju, Ravindra
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (07) : 1401 - 1411
  • [9] Multi-wavelength photoacoustic imaging for monitoring lesion formation during high-intensity focused ultrasound therapy
    Wu, Xun
    Sanders, Jean
    Dundar, Murat
    Oralkan, Omer
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2017, 2017, 10064
  • [10] Histotripsy: The Next Generation of High-Intensity Focused Ultrasound for Focal Prostate Cancer Therapy
    Dubinsky, Theodore J.
    Khokhlova, Tanya D.
    Khokhlova, Vera
    Schade, George A.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (06) : 1057 - 1067