Design of a visible tomography diagnostic for negative ion RF source SPIDER

被引:13
|
作者
Pasqualotto, R. [1 ]
Agostini, M. [1 ]
Brombin, M. [1 ]
Delogu, R. S. [1 ]
Fonnesu, N. [1 ]
Lotto, L. [1 ]
Molon, F. [1 ]
Piron, C. [1 ]
Serianni, G. [1 ]
Taliercio, C. [1 ]
Tollin, M. [1 ]
Zaniol, B. [1 ]
机构
[1] Assoc Euratom Enea Fus, Consorzio RFX, I-35127 Padua, Italy
关键词
Beam diagnostic; Tomography; Neutral beam injector; Negative ion source; Linear CCD camera;
D O I
10.1016/j.fusengdes.2013.02.009
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The ITER heating neutral beam injector, based on 1 MVD- ions, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on ITER. Beam intensity uniformity is required to stay within +/- 10%, thus beam profile is measured with a complementary set of diagnostics. Among them, visible tomography measures the line of sight (LOS) integrated H-alpha or D-alpha radiation generated by the collisions between fast particles and neutral background molecules, and emitted on a plane perpendicular to the beam. A sufficient number of well arranged LOSs allows a tomographic reconstruction of the 2D beam emission profile, which is proportional to the beam density. On SPIDER the system is equipped with about 3000 LOSs, grouped in 15 fans, and the tomographic algorithm is based on the pixel method. The design of the diagnostic is presented, with description of layout and main components and test of the prototype linear CCD camera. (C) 2013 Consorzio RFX Associazione Euratom ENEA sulla Fusione. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1253 / 1256
页数:4
相关论文
共 50 条
  • [41] Tomography feasibility study on the optical emission spectroscopy diagnostic for the negative ion source of the ELISE test facility
    Bonomo, F.
    Agostini, M.
    Brombin, M.
    Fantz, U.
    Franzen, P.
    Pasqualotto, R.
    Wuenderlich, D.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2014, 56 (01)
  • [42] Design and Development of a Diagnostic System for a Non-Intercepting Direct Measure of the SPIDER Ion Source Beamlet Current
    Patton, Tommaso
    Shepherd, Alastair
    Duteil, Basile Pouradier
    Garola, Andrea Rigoni
    Brombin, Matteo
    Candeloro, Valeria
    Manduchi, Gabriele
    Pavei, Mauro
    Pasqualotto, Roberto
    Pimazzoni, Antonio
    Siragusa, Marco
    Serianni, Gianluigi
    Sartori, Emanuele
    Taliercio, Cesare
    Barbato, Paolo
    Cervaro, Vannino
    Ghiraldelli, Raffaele
    Laterza, Bruno
    Rossetto, Federico
    SENSORS, 2023, 23 (13)
  • [43] Design of a versatile multiaperture negative ion source
    Cavenago, M.
    Kulevoy, T.
    Petrenko, S.
    Antoni, V.
    Bigi, M.
    Gazza, E.
    Recchia, M.
    Serianni, G.
    Veltri, P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):
  • [44] Modeling and design of a beam emission spectroscopy diagnostic for the negative ion source NIO1
    Barbisan, M.
    Zaniol, B.
    Cavenago, M.
    Pasqualotto, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [45] Design of an optimised movable electrostatic diagnostic for the investigation of plasma properties in a large negative ion source
    Candeloro, Valeria
    Calciolari, Luca
    Gnesotto, Francesco
    Sartori, Emanuele
    Serianni, Gianluigi
    Trevisan, Lauro
    Pasqualotto, Roberto
    FUSION ENGINEERING AND DESIGN, 2023, 190
  • [46] Status of an RF negative hydrogen ion source using transformer coupled plasma source
    Hong, IS
    Jung, HD
    Park, YS
    Hwang, YS
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS, 2002, 639 : 61 - 66
  • [47] SPIDER, the Negative Ion Source Prototype for ITER: Overview of Operations and Cesium Injection
    Serianni, G.
    Sartori, E.
    Agnello, R.
    Agostini, M.
    Barbisan, M.
    Bigi, M.
    Boldrin, M.
    Brombin, M.
    Candeloro, V.
    Casagrande, R.
    Dal Bello, S.
    Dan, M.
    Duteil, B. P.
    Fadone, M.
    Grando, L.
    Jain, P.
    Maistrello, A.
    Mario, I.
    Pasqualotto, R.
    Pavei, M.
    Pimazzoni, A.
    Poggi, C.
    Rizzolo, A.
    Shepherd, A.
    Ugoletti, M.
    Veltri, P.
    Zaniol, B.
    Agostinetti, P.
    Aprile, D.
    Berton, G.
    Cavallini, C.
    Cavazzana, R.
    Cavenago, M.
    Chitarin, G.
    Cristofaro, S.
    Croci, G.
    Cruz, N.
    Dalla Palma, M.
    Delogu, R.
    De Muri, M.
    De Nardi, M.
    Denizeau, S.
    Fellin, F.
    Ferro, A.
    Gaio, E.
    Gasparrini, C.
    Luchetta, A.
    Lunardon, F.
    Manduchi, G.
    Marconato, N.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2023, 51 (03) : 927 - 935
  • [48] First results from beam emission spectroscopy in SPIDER negative ion source
    Barbisan, M.
    Zaniol, B.
    Pasqualotto, R.
    Serianni, G.
    Ugoletti, M.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2021, 63 (12)
  • [49] Metal Negative Ion Production by an RF Sputter Self-Extraction Ion Source
    Yamada, N.
    Kasuya, T.
    Kenmotsu, T.
    Vasquez, M. R., Jr.
    Wada, M.
    THIRD INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2012), 2013, 1515 : 491 - 497
  • [50] A 1D Ion Species Model for an RF Driven Negative Ion Source
    Turner, I.
    Holmes, A. J. T.
    FIFTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2016), 2017, 1869