Design of a visible tomography diagnostic for negative ion RF source SPIDER

被引:13
|
作者
Pasqualotto, R. [1 ]
Agostini, M. [1 ]
Brombin, M. [1 ]
Delogu, R. S. [1 ]
Fonnesu, N. [1 ]
Lotto, L. [1 ]
Molon, F. [1 ]
Piron, C. [1 ]
Serianni, G. [1 ]
Taliercio, C. [1 ]
Tollin, M. [1 ]
Zaniol, B. [1 ]
机构
[1] Assoc Euratom Enea Fus, Consorzio RFX, I-35127 Padua, Italy
关键词
Beam diagnostic; Tomography; Neutral beam injector; Negative ion source; Linear CCD camera;
D O I
10.1016/j.fusengdes.2013.02.009
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The ITER heating neutral beam injector, based on 1 MVD- ions, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on ITER. Beam intensity uniformity is required to stay within +/- 10%, thus beam profile is measured with a complementary set of diagnostics. Among them, visible tomography measures the line of sight (LOS) integrated H-alpha or D-alpha radiation generated by the collisions between fast particles and neutral background molecules, and emitted on a plane perpendicular to the beam. A sufficient number of well arranged LOSs allows a tomographic reconstruction of the 2D beam emission profile, which is proportional to the beam density. On SPIDER the system is equipped with about 3000 LOSs, grouped in 15 fans, and the tomographic algorithm is based on the pixel method. The design of the diagnostic is presented, with description of layout and main components and test of the prototype linear CCD camera. (C) 2013 Consorzio RFX Associazione Euratom ENEA sulla Fusione. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1253 / 1256
页数:4
相关论文
共 50 条
  • [11] Design of a beam emission spectroscopy diagnostic for negative ions radio frequency source SPIDER
    Zaniol, B.
    Pasqualotto, R.
    Barbisan, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (04):
  • [12] Castellated tiles as the beam-facing components for the diagnostic calorimeter of the negative ion source SPIDER
    Peruzzo, S.
    Cervaro, V.
    Dalla Palma, M.
    Delogu, R.
    De Muri, M.
    Fasolo, D.
    Franchin, L.
    Pasqualotto, R.
    Pimazzoni, A.
    Rizzolo, A.
    Tollin, M.
    Zampieri, L.
    Serianni, G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [13] Development and first operation of a cavity ring down spectroscopy diagnostic in the negative ion source SPIDER
    Barbisan, M.
    Pasqualotto, R.
    Agnello, R.
    Pilieci, M.
    Serianni, G.
    Taliercio, C.
    Cervaro, V
    Rossetto, F.
    Tiso, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):
  • [14] Optimization design of magnetic filter for the prototype RF negative ion source at ASIPP
    Hu, Chundong
    Wang, Qi
    Wei, Jianglong
    Xie, Yahong
    Liang, Lizhen
    Xu, Yongjian
    Gu, Yuming
    Jiang, Caichao
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (11):
  • [15] Visible camera-based diagnostic to study negative ion beam profiles in ROBIN ion source
    Dash, Sidharth
    Bandyopadhyay, Mainak
    Pandya, Kaushal
    Bhuyan, Manas
    Yadav, Ratnakar
    Mistri, Hiren
    Singh, Mahendrajit
    20TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2024, 2743
  • [16] Measurement of stripping losses in the negative ion source SPIDER
    Agnello, R.
    Barbisan, M.
    Pasqualotto, R.
    Pimazzoni, A.
    Poggi, C.
    Sartori, E.
    Serianni, G.
    FUSION ENGINEERING AND DESIGN, 2023, 186
  • [17] First operations with caesium of the negative ion source SPIDER
    Sartori, E.
    Agostini, M.
    Barbisan, M.
    Bigi, M.
    Boldrin, M.
    Brombin, M.
    Casagrande, R.
    Dal Bello, S.
    Dan, M.
    Duteil, B. P.
    Fadone, M.
    Grando, L.
    Maistrello, A.
    Pavei, M.
    Pimazzoni, A.
    Poggi, C.
    Rizzolo, A.
    Shepherd, A.
    Ugoletti, M.
    Veltri, P.
    Zaniol, B.
    Agnello, R.
    Agostinetti, P.
    Antoni, V.
    Aprile, D.
    Candeloro, V.
    Cavallini, C.
    Cavazzana, R.
    Cavenago, M.
    Chitarin, G.
    Cristofaro, S.
    Dalla Palma, M.
    Delogu, R.
    De Muri, M.
    Denizeau, S.
    Fellin, F.
    Ferro, A.
    Gasparrini, C.
    Jain, P.
    Luchetta, A.
    Manduchi, G.
    Marconato, N.
    Marcuzzi, D.
    Mario, I.
    Milazzo, R.
    Pasqualotto, R.
    Patton, T.
    Pilan, N.
    Recchia, M.
    Rigoni-Garola, A.
    NUCLEAR FUSION, 2022, 62 (08)
  • [18] Negative ion density in the ion source SPIDER in Cs free conditions
    Barbisan, M.
    Agnello, R.
    Casati, G.
    Pasqualotto, R.
    Poggi, C.
    Sartori, E.
    Spolaore, M.
    Serianni, G.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2022, 64 (06)
  • [19] Thermo-mechanical design of the extraction grids for RF negative ion source at HUST
    Zuo, Chen
    Liu, Kaifeng
    Li, Dong
    Mei, Zhiyuan
    Zhang, Zhe
    Chen, Dezhi
    FUSION ENGINEERING AND DESIGN, 2017, 114 : 1 - 5
  • [20] Negative ion beam extraction in volume mode on the RF negative ion source at ASIPP
    Cui, Qinglong
    Wei, Jianglong
    Wang, Qi
    Pan, Junjun
    Chen, Shiyong
    Xie, Yahong
    Jiang, Caichao
    Zhao, Yuanzhe
    Xu, Yongjian
    Xie, Yuanlai
    Hu, Chundong
    FUSION ENGINEERING AND DESIGN, 2020, 161