Effect of simulated outage conditions in acid environment containing copper on corrosion of steam generator tubes

被引:0
|
作者
zur Nedden, L [1 ]
Stubbe, J [1 ]
Pierson, E [1 ]
机构
[1] Laborelec, B-1650 Linkebeek, Belgium
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In some cases, the stress corrosion cracking (SCC) of steam generator (SG) tubes seems to depend on the number! of cycles and shutdowns, more than on time of exposure itself.(1) On the other hand, corrosion tests performed at Laborelec have shown the deleterious influence of copper oxide in acid environment, especially for alloys 600 and 690 with iron and sodium sulfate solutions. (2) If copper is present in the SG, it may become oxidized during the shutdown in presence of air and stagnant water :in particular at-the top of tubesheet. Therefore, Laborelec completed a series of capsule tests to verify the influence of-cold shutdowns on corrosion in the case of acid sulfate environment containing metallic copper: the tests were interrupted every 24 to 120 h and the capsules were aerated either in "dry" or in "wet" conditions. To check the influence of mere temperature variation at shutdown, without possibility of copper oxidation, tests were performed without aerating the capsules during the stoppages. Reference tests were also performed without interruption, with metallic copper or with copper oxide, to evaluate the influence of the stoppages. The overall effect of outages was difficult to evaluate because the test periods used in this program (between two outages) appeared too short to allow initiation of cracks, at least for outage simulations in reducing conditions. On the other hand, significant results were obtained in oxidizing conditions. The main result-from this test program is that the "natural" oxidation of metallic copper during outage at roots temperature (particularly in dry conditions); increases the risk of SCC for alloys 600 and 690 when subsequently exposed to acid sulfate environments. For alloy 690, the presence of metallic copper in reduding conditions can also lead to SCC in acid sulfate environments whereas this alloy::is totally immune in absence of copper.
引用
收藏
页码:91 / 99
页数:3
相关论文
共 50 条
  • [21] Analysis corrosion dots of steam generator tubes based on acoustic emission technique
    Hou, Su-Xia
    Luo, Ji-Jun
    Zhang, Qing-Hua
    Xu, Jun
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (03): : 315 - 319
  • [22] Corrosion of alloy 690 in simulated steam generator chemistry with boiling-effect of chloride and sulfate impurities
    Sipila, Konsta
    Ikalainen, Tiina
    Lavonen, Tiina
    Saario, Timo
    Huotilainen, Caitlin
    Betova, Iva
    Bojinov, Martin
    ELECTROCHIMICA ACTA, 2023, 447
  • [23] Corrosion of Alloy 690 in Simulated Steam Generator Crevices: Effect of Applied Potential, pH and Pb Addition
    Betova, Iva
    Bojinov, Martin
    Ikalainen, Tiina
    Saario, Timo
    Sipila, Konsta
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (02)
  • [24] Corrosion of carbon steel 1018 under steam generator conditions
    Lu, YC
    Dupuis, M
    Lavoie, P
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON ENVIRONMENTAL DEGRADATION OF MATERIALS IN NUCLEAR POWER SYSTEMS - WATER REACTORS, VOLS 1 AND 2, 1997, : 175 - 182
  • [25] Electrochemical corrosion behavior of bronze materials in an acid-containing simulated atmospheric environment
    Cai, Lankun
    Chen, Mengjie
    Wang, Ying
    Chen, Cheng
    Zhang, Lehua
    Zhou, Hao
    Wu, Laiming
    Yan, Ying
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2020, 71 (03): : 464 - 473
  • [26] Electrochemical investigations of copper corrosion in simulated uterine environment
    Ramesh, S
    Kannan, S
    Rajeswari, S
    BULLETIN OF ELECTROCHEMISTRY, 2003, 19 (07): : 305 - 310
  • [27] The Synergistic Impurities Effect on the Candu Steam Generator Corrosion
    Lucan, Dumitra
    Velciu, Lucian
    Jinescu, Gheorghita
    REVISTA DE CHIMIE, 2016, 67 (04): : 603 - 608
  • [28] Corrosion behaviour of aluminium in copper containing environment
    Bakos, I.
    Szabo, S.
    CORROSION SCIENCE, 2008, 50 (01) : 200 - 205
  • [29] Influence of Temperature and Flow Rate on Erosion-Corrosion of Low-Alloy Steel in Simulated Steam Generator Conditions
    Bojinov, Martin
    Betova, Iva
    Ivanova, Nikoleta
    Karastoyanov, Vasil
    MATERIALS, 2025, 18 (05)
  • [30] Corrosion of copper in simulated nuclear waste repository conditions
    Betova, I
    Beverskog, BR
    Bojinov, M
    Kinnunen, P
    Mäkelä, K
    Pettersson, SO
    Saario, T
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2003, 6 (04) : B19 - B22