Dose Perturbations at Heterogeneous Interfaces in Radiotherapy - an EGSnrc based Monte Carlo Investigation

被引:0
|
作者
Ahmad, Muhammad Adeel [1 ]
Ahmed, Shahbaz [1 ]
Kakakhel, Muhammad Basim [1 ]
Rehman, Shakeel Ur [1 ]
Mirza, Sikander M. [1 ]
机构
[1] PIEAS, DPAM, Islamabad, Pakistan
来源
2016 INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET) | 2016年
关键词
interface dosimetry; air cavity; Lung heterogeneity; backscatter dose factor; Forward-scatter dose factor; EGSnrc; DOSXYZnrc; BEAMnrc; ATOMIC-NUMBER INTERFACES; X-RAY-BEAMS; PHOTON BEAMS; HIGH-ENERGY; AIR CAVITIES; RADIATION; CODE; MEDIA;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Radiotherapy dose computation in the presence of tissue heterogeneities presents a challenge for the treatment planning system (TPS). This study presents a Monte Carlo (MC) investigation of dose perturbation due to various kinds of heterogeneities (soft tissue interfaces with bone, air, lung and metallic implants) for a range of clinically useful photon energies and field sizes. EGSnrc MC radiation transport code has been used for linear accelerator head modeling and phantom dose calculations. Dose perturbations were quantified in terms of forward- and backscatter factors as well as inside the heterogeneity of low densities for various field sizes including 5 x 5 cm(2), 10 x 10 cm(2) and 15 x 15 cm(2). For lung heterogeneity, both under-dosage and over-dosage has been assessed in relation to the field sizes and energies. These simulations confirm under-dosage in the case of lung heterogeneity for small field sizes, which increases with the energy. However, lung tissues reflect an overdose with smaller energies and larger field sizes.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Fast CPU-based Monte Carlo simulation for radiotherapy dose calculation
    Ziegenhein, Peter
    Pirner, Sven
    Kamerling, Cornelis Ph
    Oelfke, Uwe
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 6097 - 6111
  • [32] Independent Monte-Carlo dose calculation for MLC based CyberKnife radiotherapy
    Mackeprang, P-H
    Vuong, D.
    Volken, W.
    Henzen, D.
    Schmidhalter, D.
    Malthaner, M.
    Mueller, S.
    Frei, D.
    Stampanoni, M. F. M.
    Dal Pra, A.
    Aebersold, D. M.
    Fix, M. K.
    Manser, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01):
  • [33] Fast CPU-based Monte Carlo simulation for radiotherapy dose calculation
    Ziegenhein, P.
    Pirner, S.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S452 - S453
  • [34] Validation of Monte Carlo Dose Algorithm in Heterogeneous Medium
    Sethi, A.
    Leo, P.
    Kabat, C.
    Cecilio, P.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [35] Monte Carlo investigation of dose perturbation by hip replacements in intensity modulated radiotherapy of prostate cancer
    Chen, Z.
    Ma, C.
    Li, J.
    Paskalev, K.
    Price, R.
    Luo, W.
    Fan, J.
    Chen, Y.
    Lin, T.
    Chen, L.
    MEDICAL PHYSICS, 2006, 33 (06) : 2122 - 2123
  • [36] Energy Modulated Photon Radiotherapy: A Monte Carlo Investigation
    Zhang, Y.
    Feng, Y.
    Ming, X.
    Nath, R.
    Deng, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [37] Monte Carlo calculation of dose perturbations due to Metallic Esophageal stents
    Li, XA
    MEDICAL PHYSICS, 2002, 29 (06) : 1295 - 1295
  • [38] Development of a GPU-Based Monte Carlo Dose Calculation Package for Cancer Radiotherapy
    Jia, X.
    Gu, X.
    Graves, Y.
    Jiang, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [39] A comparison of Monte Carlo and model-based dose calculations in radiotherapy using MCNPTV
    Wyatt, Mark S.
    Miller, Laurence F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 562 (02): : 1013 - 1016
  • [40] Development of a GPU-Based Monte Carlo Dose Calculation Package for Proton Radiotherapy
    Jia, X.
    Schuemann, J.
    Paganetti, H.
    Jiang, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3945 - 3945