Nasal High-Frequency Oscillation for Lung Carbon Dioxide Clearance in the Newborn

被引:71
|
作者
Mukerji, Amit [1 ]
Finelli, Michael [1 ]
Belik, Jaques [1 ]
机构
[1] Univ Toronto, Hosp Sick Children, Dept Pediat, Div Neonatol, Toronto, ON M5G 1X8, Canada
关键词
Ventilator-induced lung injury; Noninvasive ventilation; Bronchopulmonary dysplasia; POSITIVE AIRWAY PRESSURE; VENTILATION; EFFICACY; TRIAL;
D O I
10.1159/000345613
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Noninvasive ventilation has been used increasingly in recent years to minimize the duration of endotracheal mechanical ventilation in neonates due to its association with lung injury. Nasal high-frequency oscillation (nHFO) is a relatively new noninvasive modality but evidence for its use is limited. Objective: The goal of this study was to compare the CO2 clearance efficacy of nHFO and noninvasive positive pressure ventilation (NIPPV) in a neonatal lung model. Design/Methods: A newborn mannequin with dimensions and anatomy similar to a term infant was utilized. It was connected to a commercially available neonatal mechanical ventilator using a manufacturer-provided nasal adaptor. Various modes of noninvasive ventilation were compared as CO2 clearance was measured at the oropharynx by an end-tidal CO2 analyzer following the addition of a known amount of CO2 into the lung. Measurements were obtained at two different lung compliances using nHFO and compared with nCMV and nasal continuous positive airway pressure (nCPAP) as a control. Pressures near the nasal adaptor and the larynx were simultaneously measured with in-line pressure transducers. Results: Whereas no CO2 elimination was observed under nCPAP, its clearance with nHFO was 3-fold greater as compared to NIPPV. On nHFO, CO2 clearance was inversely proportional to frequency and maximal at 6 and 8 Hz. At a lower lung compliance, CO2 clearance was significantly higher at 6 Hz as compared to 10 Hz. During nHFO set to deliver a MAP of 10.0, we documented pressures of 7.2 +/- 0.3 at the nasal adaptor and only 2.3 +/- 0.3 cm H2O at the larynx. Conclusions: Nasal HFO is effective and superior to NIPPV at lung CO2 elimination in a newborn mannequin model. The use of nHFO as the preferred mode of non-invasive ventilation warrants further clinical studies. Copyright (C) 2012 S. Karger AG, Basel
引用
收藏
页码:161 / 165
页数:5
相关论文
共 50 条
  • [21] Nasal high frequency oscillation and nasal continuous positive airway pressure for respiratory insufficiency in newborn infants
    Brouwer, EG
    vanderHoeven, MA
    Gavilanes, DW
    Degraeuwe, PL
    Maertzdorf, WJ
    Blanco, CE
    PEDIATRIC RESEARCH, 1996, 39 (04) : 1946 - 1946
  • [22] Nasal high-frequency oscillation ventilation in neonates: a survey in five European countries
    Fischer, Hendrik Stefan
    Bohlin, Kajsa
    Buehrer, Christoph
    Schmalisch, Gerd
    Cremer, Malte
    Reiss, Irwin
    Czernik, Christoph
    EUROPEAN JOURNAL OF PEDIATRICS, 2015, 174 (04) : 465 - 471
  • [23] Conventional ventilation versus high-frequency oscillation: Hemodynamic effects in newborn babies
    Simma, B
    Fritz, M
    Fink, C
    Hammerer, I
    CRITICAL CARE MEDICINE, 2000, 28 (01) : 227 - 231
  • [24] RENAL-FUNCTION DURING VENTILATION BY HIGH-FREQUENCY OSCILLATION IN THE NEWBORN RABBIT
    COTTING, J
    GUIGNARD, JP
    INTERNATIONAL JOURNAL OF PEDIATRIC NEPHROLOGY, 1983, 4 (04): : 282 - 283
  • [25] NASAL HIGH-FREQUENCY OSCILLATION PROVIDES ACCEPTABLE RESPIRATORY SUPPORT FOR PREMATURE LAMBS
    Dahl, M.
    Zuspan, K.
    Bowen, S.
    Bradford, C.
    Pettet, L.
    Null, D.
    Yoder, B.
    Albertine, K.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2016, 64 (01) : 179 - 180
  • [26] Nasal high-frequency oscillation ventilation in neonates: a survey in five European countries
    Hendrik Stefan Fischer
    Kajsa Bohlin
    Christoph Bührer
    Gerd Schmalisch
    Malte Cremer
    Irwin Reiss
    Christoph Czernik
    European Journal of Pediatrics, 2015, 174 : 465 - 471
  • [27] TRACHEAL MUCUS CLEARANCE IN HIGH-FREQUENCY OSCILLATION .2. CHEST WALL VERSUS MOUTH OSCILLATION
    KING, M
    PHILLIPS, DM
    ZIDULKA, A
    CHANG, HK
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1984, 130 (05): : 703 - 706
  • [28] High-Frequency Oscillation for ARDS
    Muellenbach, Ralf M.
    Kredel, Markus
    Kranke, Peter
    NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (23): : 2232 - 2233
  • [29] High-frequency oscillation in adolescents
    Moganasundram, S
    Durward, A
    Tibby, SM
    Murdoch, IA
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (05) : 708 - U3
  • [30] A REVIEW OF HIGH-FREQUENCY OSCILLATION
    KOLTON, M
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1984, 31 (04) : 416 - 429