Development of multi-purpose 3D printed phantoms for MRI

被引:13
|
作者
Rai, Robba [1 ,2 ,3 ]
Wang, Yu Feng [4 ]
Manton, David [3 ]
Dong, Bin [3 ]
Deshpande, Shrikant [1 ,2 ,3 ,5 ]
Liney, Gary P. [1 ,2 ,3 ,5 ]
机构
[1] Univ New South Wales, South Western Sydney Clin Sch, Liverpool, NSW 2170, Australia
[2] Liverpool Hosp, Liverpool & Macarthur Canc Therapy Ctr, Liverpool, NSW 2170, Australia
[3] Ingham Inst Appl Med Res, Liverpool, NSW 2170, Australia
[4] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW, Australia
[5] Univ Wollongong, Ctr Radiat Phys, Wollongong, NSW 2522, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 07期
关键词
3D printing; geometric distortion; image quantification; MRI; test objects; texture analysis; TEXTURE ANALYSIS; QUALITY-ASSURANCE; HEAD PHANTOM; DISTORTION; FOAM;
D O I
10.1088/1361-6560/ab0b49
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work describes the development and application of 3D printed MRI phantoms. Unlike traditional phantoms these test objects are made from solid materials which can be imaged directly without filling. The models were manufactured using both MRI visible and invisible materials. The MRI visible materials were imaged on a 3T system to quantify their T-1 and T-2 properties and CT to quantify the electron density. Three phantoms are described: a distortion phantom was imaged on an open bore MRI system to assess distortion over a 30 cm field-of-view; a solid tumour model was imaged using a motion simulator and compared to a standard water phantom to assess reduction in artefacts; finally, a test object created for textural analysis was evaluated on two 3T systems and reproducibility was assessed. Material 1 was the main material used in all phantom models and has a T-1 and T-2 of 152.3 +/- 3.7 ms and 56.7 +/- 2.5 ms and a CT density of 127.9 HU. Material 2 had a CT density of 115.1 HU and material 3 had a T-1 and T-2 of 149.5 +/- 2.9 ms and 68.8 +/- 7.8 ms and CT density of 15.3 HU. Image tests demonstrated the suitability and advantage of each phantom over more traditional versions: a high density set of control points enabled a comprehensive measurement of geometric accuracy; sufficient signal with a reduction in artefact was observed in the motion phantom, and the texture model provided reproducible measurements with an ICC > 0.9 for over 76% of texture features. Three different phantoms have been successfully manufactured and used to demonstrate the application of 3D printable materials for MRI phantoms.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [31] 3D printed phantoms for medical imaging: recent developments and challenges
    Wegner, Marie
    Krause, Dieter
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2024, : 4537 - 4543
  • [32] Controlled Compliancy of 3D Printed Vascular Patient Specific Phantoms
    Allman, Ariana B.
    Shepard, Lauren M.
    Podgorsak, Alexander R.
    Rava, Ryan A.
    Ionita, Ciprian N.
    MEDICAL IMAGING 2019: IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, 2019, 10954
  • [33] Commentary: Accessing 3D Printed Vascular Phantoms for Procedural Simulation
    Singh, Som P.
    Qureshi, Fahad M. M.
    Baig, Farhan
    FRONTIERS IN SURGERY, 2022, 9
  • [34] Validation of Computational Fluid Dynamics Methods with Anatomically Exact, 3D Printed MRI Phantoms and 4D pcMRI
    Anderson, Jeff R.
    Diaz, Orlando
    Klucznik, Richard
    Zhang, Y. Jonathan
    Britz, Gavin W.
    Grossman, Robert G.
    Lv, Nan
    Huang, Qinghai
    Karmonik, Christof
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6699 - 6701
  • [35] Development of a 3D Printed Multi-Axial Force Sensor
    Ji, Qinglei
    Fu, Shuo
    Feng, Lei
    Andrikopoulos, Georgios
    Wang, Xi Vincent
    Wang, Lihui
    SPS 2022, 2022, 21 : 604 - 614
  • [36] Reproducing 2D Breast Mammography Images with 3D Printed Phantoms
    Clark, Matthew
    Ghammraoui, Bahaa
    Badal, Andreu
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [37] Development of multi-purpose CAD system for roll forming
    Li, Guozhong
    He, Yuxin
    Kang T'ieh/Iron and Steel (Peking), 1988, 23 (11): : 30 - 34
  • [38] History and recent development of multi-purpose utility tunnels
    Luo, Y.
    Alaghbandrad, A.
    Genger, T. K.
    Hammad, A.
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 103
  • [39] Development of multi-purpose MW gyrotrons for fusion devices
    Minami, R.
    Kariya, T.
    Imai, T.
    Numakura, T.
    Endo, Y.
    Nakabayashi, H.
    Eguchi, T.
    Shimozuma, T.
    Kubo, S.
    Yoshimura, Y.
    Igami, H.
    Takahashi, H.
    Mutoh, T.
    Ito, S.
    Idei, H.
    Zushi, H.
    Yamaguchi, Y.
    Sakamoto, K.
    Mitsunaka, Y.
    NUCLEAR FUSION, 2013, 53 (06)
  • [40] DEVELOPMENT OF A NEW MULTI-PURPOSE UAS FOR SCIENTIFIC APPLICATION
    Scholtz, A.
    Kaschwich, C.
    Krueger, A.
    Kufieta, K.
    Schnetter, P.
    Wilkens, C. -S.
    Krueger, T.
    Voersmann, P.
    INTERNATIONAL CONFERENCE ON UNMANNED AERIAL VEHICLE IN GEOMATICS (UAV-G), 2011, 38-1 (C22): : 149 - 154