Reproducing 2D Breast Mammography Images with 3D Printed Phantoms

被引:6
|
作者
Clark, Matthew [2 ]
Ghammraoui, Bahaa [1 ]
Badal, Andreu [1 ]
机构
[1] US FDA, Div Imaging Diagnost & Software Reliabil, OSEL, CDRH, Silver Spring, MD USA
[2] Univ Maryland, Mech Engn, College Pk, MD 20742 USA
关键词
mammography; breast phantoms; 3D printing;
D O I
10.1117/12.2217215
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Mammography is currently the standard imaging modality used to screen women for breast abnormalities and, as a result, it is a tool of great importance for the early detection of breast cancer. Physical phantoms are commonly used as surrogates of breast tissue to evaluate some aspects of the performance of mammography systems. However, most phantoms do not reproduce the anatomic heterogeneity of real breasts. New fabrication technologies, such as 3D printing, have created the opportunity to build more complex, anatomically realistic breast phantoms that could potentially assist in the evaluation of mammography systems. The primary objective of this work is to present a simple, easily reproducible methodology to design and print 3D objects that replicate the attenuation profile observed in real 2D mammograms. The secondary objective is to evaluate the capabilities and limitations of the competing 3D printing technologies, and characterize the x-ray properties of the different materials they use. Printable phantoms can be created using the open-source code introduced in this work, which processes a raw mammography image to estimate the amount of x-ray attenuation at each pixel, and outputs a triangle mesh object that encodes the observed attenuation map. The conversion from the observed pixel gray value to a column of printed material with equivalent attenuation requires certain assumptions and knowledge of multiple imaging system parameters, such as x-ray energy spectrum, source-to-object distance, compressed breast thickness, and average breast material attenuation. A detailed description of the new software, a characterization of the printed materials using x-ray spectroscopy, and an evaluation of the realism of the sample printed phantoms are presented.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [1] Breast phantoms for 2D digital mammography with realistic anatomical structures and attenuation characteristics based on clinical images using 3D printing
    Schopphoven, Stephan
    Cavael, Pierre
    Bock, Karin
    Fiebich, Martin
    Maeder, Ulf
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [2] Integrated 2D and 3D mammography
    Sumkin, Jules H.
    LANCET ONCOLOGY, 2013, 14 (08): : E292 - E293
  • [3] Alignment of multimodality, 2D and 3D breast images
    Grevera, GJ
    Udupa, JK
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1135 - 1143
  • [4] Breast microcalcification classification: From 2D mammography to 3D digital breast tomosynthesis
    Yeh, Jinn-Yi
    Chan, Siwa
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2022, 18 : 43 - 43
  • [5] Dose Assessment in 2D and 3D Mammography
    Saadi, S.
    Merad, A.
    Khelassi-Toutaoui, N.
    Boubrit, M.
    1ST INTERNATIONAL CONFERENCE ON RADIATIONS AND APPLICATIONS (ICRA-2017), 2018, 1994
  • [6] MRI - Mammography 2D/3D data fusion for breast pathology assessment
    Behrenbruch, CP
    Marias, K
    Armitage, PA
    Yam, M
    Moore, N
    English, RE
    Brady, JM
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 307 - 316
  • [7] The simulation of 3D mass models in 2D digital mammography and breast tomosynthesis
    Shaheen, Eman
    De Keyzer, Frederik
    Bosmans, Hilde
    Dance, David R.
    Young, Kenneth C.
    Van Ongeval, Chantal
    MEDICAL PHYSICS, 2014, 41 (08) : 383 - 399
  • [9] Spatial correlation of 2D hard-tissue histology with 3D microCT scans through 3D printed phantoms
    Philipp Nolte
    Marcel Brettmacher
    Chris Johann Gröger
    Tim Gellhaus
    Angelika Svetlove
    Arndt F. Schilling
    Frauke Alves
    Christoph Rußmann
    Christian Dullin
    Scientific Reports, 13
  • [10] Spatial correlation of 2D hard-tissue histology with 3D microCT scans through 3D printed phantoms
    Nolte, Philipp
    Brettmacher, Marcel
    Groger, Chris Johann
    Gellhaus, Tim
    Svetlove, Angelika
    Schilling, Arndt F.
    Alves, Frauke
    Russmann, Christoph
    Dullin, Christian
    SCIENTIFIC REPORTS, 2023, 13 (01)