Resonance frequency detection system of Piezoelectric Micro-cantilever

被引:0
|
作者
Hu Chang-de [1 ]
Zhao Mei-rong [2 ]
Deng Xiao-bei [3 ]
Zhu Sha [1 ]
机构
[1] Acad Equipment Command & Technol, Dept Noncommissioned Officer, Beijing, Peoples R China
[2] Tianjin Univ, State Key Lab Precis Measuring Technol & Measurem, Tianjin, Peoples R China
[3] Off Peoples Republ China Patent Examinat Coop Ctr, State Intellectual Property, Commun Invent Examinat Div, Beijing, Peoples R China
关键词
piezoelectric micro-cantilever; resonance frequency; amplitude; piezoelectric film;
D O I
10.4028/www.scientific.net/AMR.443-444.115
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A kind of resonance frequency detection of piezoelectric micro-cantilever is presented, where there is piezoelectric film deposited. The alternating current is put on the film to make it vibrate, and when resonance frequency happens, the amplitude of piezoelectric micro-cantilever reaches the maximal. A series of experiments have been done by the driving power and detecting power designed by ourselves. The experiments show that resonance frequency can be detected by the amplifier, and the amplitude of the resonance frequency is obviously bigger than the amplitude of the other frequency. The maximal amplitude is about 600nm.
引用
收藏
页码:115 / +
页数:2
相关论文
共 50 条
  • [21] Vibration boundary control of micro-cantilever Timoshenko beam using piezoelectric actuators
    Mehrvarz, A.
    Salarieh, H.
    Alasty, A.
    Vatankhah, R.
    SCIENTIA IRANICA, 2018, 25 (02) : 711 - 720
  • [22] Tip tracking control of a micro-cantilever Timoshenko beam via piezoelectric actuator
    Shirazi, Masoud Jahromi
    Salarieh, Hassan
    Alasty, Aria
    Shabani, Rasool
    JOURNAL OF VIBRATION AND CONTROL, 2013, 19 (10) : 1561 - 1574
  • [23] Spore detection in air and fluid using micro-cantilever sensors
    Davila, Angelica P.
    Gupta, Amit
    Walter, Tom
    Akin, Demir
    Aronson, Arthur
    Bashir, Rashid
    MATERIAL AND DEVICES FOR SMART SYSTEMS II, 2006, 888 : 197 - +
  • [24] Micro-Cantilever Displacement Detection Based in Optical Fiber Tip
    Robalinho, Paulo
    Frazao, Orlando
    SENSORS, 2019, 19 (22)
  • [25] Concentration quantitative detection of micro-quantity liquid based on micro-cantilever
    Zhang Z.
    Jin T.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (02): : 26 - 32
  • [27] Micro-cantilever array pressure measurement system for biomedical instrumentation
    Qu, Wenchao
    Islam, Syed K.
    To, Gary
    Mahfouz, Mohamed R.
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 1009 - 1012
  • [28] Toxic Gas Sensor Using Resonant Frequency Variation in Micro-Cantilever
    Subhashini, S.
    Juliet, A. Vimala
    2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT), 2012, : 87 - 91
  • [29] Micro-cantilever resonance sensor for biomolecular detection by using self-assembly nano-particles
    He, J. H.
    Sun, S. Q.
    Li, Y. F.
    Ye, J. S.
    Kong, J. M.
    Cai, Y. L.
    Li, C. W. H.
    Lim, T. M.
    Hui, W. C.
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS IV, 2006, 6112
  • [30] Design and fabrication of electrostatic micro-cantilever array as audible frequency generator
    Arya, Sandeep
    Khan, Saleem
    Lehana, Parveen
    JOURNAL OF ELECTROSTATICS, 2015, 76 : 145 - 151