Structure Design and Optimization of the C5-C6 Cervical Intervertebral Fusion Cage Using the Anterior Cervical Plate and Cage Fixation System

被引:3
|
作者
Wang, Jiajia [1 ,2 ]
Qian, Zhihui [2 ]
Cui, Changlei [3 ]
Guo, Zhijun [4 ]
Ren, Luquan [2 ]
机构
[1] Henan Univ Sci & Technol, Coll Agr Equipment Engn, Luoyang, Henan, Peoples R China
[2] Jilin Univ, Minist Educ, Key Lab Bion Engn, Changchun, Jilin, Peoples R China
[3] First Hosp Jilin Univ, Dept Anesthesiol, Changchun, Jilin, Peoples R China
[4] Henan Univ Sci & Technol, Coll Vehicle & Transportat Engn, Luoyang, Henan, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2020年 / 26卷
基金
中国国家自然科学基金;
关键词
Finite Element Analysis; Postoperative Complications; Prosthesis Implantation; FINITE-ELEMENT-ANALYSIS; INTERBODY FUSION; NECK MOVEMENTS; MODEL; LOAD; VALIDATION; SUBSIDENCE; DISKECTOMY; STABILITY;
D O I
10.12659/MSM.924236
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The fifth and sixth cervical vertebra (C5-C6) is the most easily injured segment encountered in clinical practice. The anterior cervical plate and cage (ACPC) fixation system is always used to reconstruct the intervertebral height and maintain the segmental stability. The postoperative effect, such as subsidence, neck pain, and non-fusion, is greatly affected by the cervical cage structure design. This study determined reasonable structure size parameters that present optimized biomechanical properties related to the postoperative subsidence often accompanied with ACPC. Material/Methods: Twenty bionic cages with different structural sizes (distance between the center of the cage and groove, groove depth, and groove width) were designed and analyzed based on the regression optimization design and analysis method combined with FE analysis. Because a previous study showed that greater stresses on the endplate are associated with higher risk of subsidence, the optimization object was selected as the stresses on endplate to lower it. Results: The postoperative stresses on the endplate of all cages with bionic structure design were proved to be low- er than with the original one. The optimal structure size was the distance between the center of the cage and groove=0 mm, groove depth=3 mm, and groove width=4 mm. Regression analysis found the cage with optimized bionic structural parameters resulted in a 22.58% reduction of endplate stress response compared with the original one. Conclusions: The bionic cage with optimized structural sizes can reduce the subsidence risk, suggesting that the optimization method has great potential applications in the biomechanical engineering field.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] The Efficacy of Plate Construct Augmentation Versus Cage Alone in Anterior Cervical Fusion
    Song, Kyung-Jin
    Taghavi, Cyrus E.
    Lee, Kwang-Bok
    Song, Ji-Hoon
    Eun, Jong-Pil
    SPINE, 2009, 34 (26) : 2886 - 2892
  • [23] Zero-profile anchored cage reduces risk of postoperative dysphagia compared with cage with plate fixation after anterior cervical discectomy and fusion
    ShanWen Xiao
    ZhuDe Liang
    Wu Wei
    JinPei Ning
    European Spine Journal, 2017, 26 : 975 - 984
  • [24] Zero-profile anchored cage reduces risk of postoperative dysphagia compared with cage with plate fixation after anterior cervical discectomy and fusion
    Xiao, ShanWen
    Liang, ZhuDe
    Wei, Wu
    Ning, JinPei
    EUROPEAN SPINE JOURNAL, 2017, 26 (04) : 975 - 984
  • [25] Radiographic Comparison of Four Anterior Fusion Methods in Two Level Cervical Disc Diseases: Autograft Plate Fixation versus Cage Plate Fixation versus Stand-Alone Cage Fusion versus Corpectomy and Plate Fixation
    Kim, Min-Ki
    Kim, Sung-Min
    Jeon, Kwang-Mo
    Kim, Tae-Sung
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2012, 51 (03) : 135 - 140
  • [26] Comparing anterior cervical fusion using titanium cage with hydroxyapatite and with autograft
    Tienboon, Prakit
    Atiprayoon, Surapon
    ASIAN BIOMEDICINE, 2010, 4 (01) : 147 - 152
  • [27] Treatment of Spondylotic Cervical Myelopathy: Anterior Cervical Discectomy and Fusion With a Modular Plate-cage System (PCB) in the Singlelevel and Multilevel Cervical Myelopathy
    Costa, Francesco
    Cardia, Andrea
    Ortolina, Alessandro
    Galbusera, Fabio
    Menghetti, Claudia
    De Santis, Antonio
    Zerbi, Alberto
    Fornari, Maurizio
    NEUROSURGERY QUARTERLY, 2012, 22 (02) : 88 - 93
  • [28] Long term results of simultaneous cornerstone carbon cage fusion and anterior cervical plate fixation in cervical degenerative disc disease with ligament instability
    Kowalczyk, P
    Zakrzewska, A
    Marchel, A
    Proceedings of the 13th World Congress of Neurological Surgery, Vols 1 and 2, 2005, : 109 - 112
  • [30] Comparison of Clinical Outcomes Following Anterior Cervical Discectomy and Fusion with Zero-Profile Anchored Spacer-ROI-C-Fixation and Combined Intervertebral Cage and Anterior Cervical Discectomy and Fusion: A Retrospective Study from a Single Center
    He, Shuangjun
    Zhou, Zhangzhe
    Lv, Nanning
    Shao, Xiaofeng
    Zhou, Xinfeng
    Wang, Yaowei
    Wu, Shuhua
    Chen, Kangwu
    Zhou, Lijian
    Qian, Zhonglai
    MEDICAL SCIENCE MONITOR, 2021, 27