Heart rate variability in physically active individuals: reliability and gender characteristics

被引:0
|
作者
Sookan, Takshita [1 ]
McKune, Andrew J. [1 ]
机构
[1] Univ KwaZulu Natal, Dept Biokinet Exercise & Leisure Sci, Sch Hlth Sci, Durban, South Africa
关键词
heart rate variability; sympathovagal balance; reliability; AGE; POPULATION; TIME; RISK;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the reliability of short-term recordings (five minutes) of heart rate variability (HRV) and the association between HRV and gender. Methods: HRV time-and frequency-domain parameters were calculated in 44 physically active students (21 males and 23 females) over four consecutive days. A Suunto t6 heart rate monitor was used to obtain inter-beat intervals (IBIs) that were then transferred to Kubios HRV analysis software. The relative reliability [intra-class correlation (ICC)] and absolute reliability, [typical error of measurement (TEM) and typical error of measurement as a percentage (TEM%)] of the HRV parameters were then calculated for day 2 versus day 3 and day 3 versus day 4, with day 1 being a familiarisation day. The following HRV parameters were calculated: (1) time domain: resting heart rate (RHR), R-R intervals (IBI), standard deviation of normal-to-normal intervals (SDNN), root mean square differences of the standard deviation (RMSSD), percentage of beats that changed more than 50 ms from the previous beat (pNN50); and (2) frequency domain: low-frequency normalised units (LFnu), high-frequency normalised units (HFnu), low-frequency to high-frequency ratio in normalised units (LF/HFnu). An analysis of variance (ANOVA) with Tukey post-hoc testing was performed to compare HRV parameters in males and females. Significance was set at p <= 0.05. Results: The ICCs for both relationship 1 and 2 indicated primarily good to excellent (> 0.8) relative reliability. The lowest value was found in the LF/HFnu ratio (ICC = 0.36) for males. Absolute reliability was low with TEM% greater than 10% for all HRV parameters, except IBIs. Females demonstrated better relative (higher ICCs) and absolute reliability (lower TEM and TEM%) compared to males for the frequency domain. The relative and absolute reliability for the time domains were similar except for SDNN where the absolute reliability was higher in males. ANOVA illustrated significant gender differences for the LF/HFnu ratio (41% higher in males, p = 0.003), HFnu (12% higher in females, p = 0.02) and IBI (21% higher in females, p < 0.0001). Conclusions: Short-term recordings of HRV over three consecutive days demonstrated a high relative reliability. However, a low absolute reliability indicated large day-to-day random variation in HRV, which would make the detection of intervention effects using HRV difficult in individual participants. Females were shown to have a higher parasympa-thetic modulation of HRV, which may indicate an underlying cardioprotective mechanism in females compared to males.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 50 条
  • [41] Heart rate variability in individuals with thoracic spinal cord injury
    P Serra-Añó
    L L Montesinos
    J Morales
    L López-Bueno
    M Gomis
    X García-Massó
    L M González
    Spinal Cord, 2015, 53 : 59 - 63
  • [42] Influence of gestational age, heart rate, gender and time of day on fetal heart rate variability
    S. Lange
    P. Van Leeuwen
    D. Geue
    W. Hatzmann
    D. Grönemeyer
    Medical and Biological Engineering and Computing, 2005, 43 : 481 - 486
  • [43] Influence of gestational age, heart rate, gender and time of day on fetal heart rate variability
    Lange, S
    Van Leeuwen, P
    Geue, D
    Hatzmann, W
    Grönemeyer, D
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (04) : 481 - 486
  • [44] The reliability of short-term measurements of heart rate variability
    Sandercock, GRH
    Bromley, PD
    Brodie, DA
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 103 (03) : 238 - 247
  • [45] RELIABILITY AND VARIABILITY OF INDICATORS OF HEART-RATE MONITORING IN CHILDREN
    DURANT, RH
    BARANOWSKI, T
    DAVIS, H
    RHODES, T
    THOMPSON, WO
    GREAVES, KA
    PUHL, J
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1993, 25 (03): : 389 - 395
  • [46] Reliability of the heart rate variability threshold during treadmill exercise
    Hargens, Trent A.
    Chambers, Shane
    Luden, Nicholas D.
    Womack, Christopher J.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2022, 42 (04) : 292 - 299
  • [47] RELIABILITY OF HEART RATE VARIABILITY DURING DYNAMIC HANDGRIP EXERCISE
    Kluess, H. A.
    Wood, R. H.
    Stone, D. J.
    Weslch, M. A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S203 - S203
  • [48] Test-retest Reliability of Female Heart Rate Variability
    Murley, Meghan
    Marks, Charles R. C.
    Drouin, Jacqueline S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 725 - 725
  • [49] RELIABILITY AND COMPARISON OF METHODS TO CALCULATE HEART-RATE-VARIABILITY
    GELBER, D
    PFEIFER, M
    SCHUMER, M
    DIABETES, 1995, 44 : A66 - A66
  • [50] Influence of age and gender on heart rate recovery after exercise in healthy individuals was more important than indices of 24-hour heart rate variability
    Chuang, E. Y.
    Antelmi, I.
    Latorre, M. R. D. O.
    Grupi, C. J.
    Yamada, A. T.
    Araujo, F.
    Mansur
    EUROPEAN HEART JOURNAL, 2005, 26 : 255 - 256