Reliability of the heart rate variability threshold during treadmill exercise

被引:3
|
作者
Hargens, Trent A. [1 ]
Chambers, Shane [1 ]
Luden, Nicholas D. [1 ]
Womack, Christopher J. [1 ]
机构
[1] James Madison Univ, Dept Kinesiol, Human Performance Lab, 261 Bluestone Dr MSC 2302, Harrisonburg, VA 22807 USA
关键词
autonomic activity; graded exercise test; root mean square of successive differences of continuous R-R intervals; standard deviation of instantaneous beat intervals; ventilatory threshold; V-slope method; MAXIMAL OXYGEN-UPTAKE; VENTILATORY THRESHOLD; GAS-EXCHANGE; VALIDITY; AGREEMENT; INTERVALS; MODALITY; BICYCLE; TESTS;
D O I
10.1111/cpf.12760
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The heart rate variability threshold (HRVT) is a clinical parameter used to gain insight into autonomic balance. Prior validation of the HRVT has been with cycle ergometry, with no studies examining the viability of treadmill exercise. The purpose of this study was to examine the reliability of the HRVT during treadmill exercise, and to compare the HRVT to the ventilatory threshold (VT). Ten healthy, college-aged males completed two maximal graded exercise tests on a treadmill. A Polar RS800CX watch was used for heart rate and HRVT data. The HRVT was determined from three HRV variables including the root mean square of successive differences of continuous R-R intervals (RMSSD), the standard deviation of normal R-R intervals (SDNN) and the standard deviation of instantaneous beat intervals (SD1). A metabolic cart was utilized to determine the VT. Results showed no difference between the HRVT (2.4 +/- 0.6 and 2.2 +/- 0.3 for RMSSD, 2.8 +/- 0.5 and 2.7 +/- 0.5 for SDNN and 2.4 +/- 0.6 and 2.3 +/- 0.6 for SD1) or the VT (3.0 +/- 0.3 and 3.1 +/- 0.3) between trials. When compared to the VT, averaged HRVT values for RMSSD (2.3 +/- 0.3) and SD1 (2.3 +/- 0.5) were lower than averaged VT (2.8 +/- 0.4, p < 0.05). The averaged HRVT from SDNN (2.8 +/- 0.5) did not differ from the VT. These results suggest that treadmill is a viable mode for HRVT determination, and that HRVT determined by SDNN may be a better comparison to the VT.
引用
收藏
页码:292 / 299
页数:8
相关论文
共 50 条
  • [1] The response of heart rate variability during graded treadmill exercise
    Wilkinson, WJ
    Thompson, RW
    Garcia, ME
    Kampert, JB
    Laukkanen, RT
    Seppanen, T
    CIRCULATION, 1996, 94 (08) : 1465 - 1465
  • [2] RELIABILITY OF HEART RATE VARIABILITY DURING DYNAMIC HANDGRIP EXERCISE
    Kluess, H. A.
    Wood, R. H.
    Stone, D. J.
    Weslch, M. A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S203 - S203
  • [3] Heart rate control during treadmill exercise
    Su, S. W.
    Wang, L.
    Celler, B. G.
    Savkin, A. V.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2471 - 2474
  • [4] Changes in heart rate variability with respect to exercise intensity and time during treadmill running
    Kenneth J. Hunt
    Jittima Saengsuwan
    BioMedical Engineering OnLine, 17
  • [5] Changes in heart rate variability with respect to exercise intensity and time during treadmill running
    Hunt, Kenneth J.
    Saengsuwan, Jittima
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [6] Lactate and Heart Rate Variability Threshold during Resistance Exercise in the Young and Elderly
    Simoes, R. P.
    Castello-Simoes, V.
    Mendes, R. G.
    Archiza, B.
    Santos, D. A.
    Machado, H. G.
    Bonjorno, J. C., Jr.
    Oliveira, C. R.
    Reis, M. S.
    Catai, A. M.
    Arena, R.
    Borghi-Silva, A.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2013, 34 (11) : 991 - 996
  • [7] Heart rate variability during exercise performed below and above Ventilatory threshold
    Cottin, FO
    Médigue, C
    Leprétre, PM
    Papelier, Y
    Koralsztein, JP
    Billat, V
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (04): : 594 - 600
  • [8] Optimal control of heart rate during treadmill exercise
    Hunt, Kenneth J.
    Liu, Ming
    OPTIMAL CONTROL APPLICATIONS & METHODS, 2018, 39 (02): : 503 - 518
  • [9] Influence of Running Stride Frequency in Heart Rate Variability Analysis During Treadmill Exercise Testing
    Bailon, Raquel
    Garatachea, Nuria
    de la Iglesia, Ignacio
    Casajus, Jose Antonio
    Laguna, Pablo
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) : 1796 - 1805
  • [10] Reliability of heart rate variability measures at rest and during light exercise in children
    Winsley, RJ
    Armstrong, N
    Bywater, K
    Fawkner, SG
    BRITISH JOURNAL OF SPORTS MEDICINE, 2003, 37 (06) : 550 - 552