A novel approach to determine primary stability of acetabular press-fit cups

被引:12
|
作者
Weissmann, Volker [1 ,2 ]
Boss, Christian [3 ]
Bader, Rainer [2 ]
Hansmann, Harald [1 ]
机构
[1] Univ Appl Sci Technol Business & Design, Fac Engn, Philipp Muller Str 14, D-23966 Wismar, Germany
[2] Rostock Univ Med, Dept Orthoped, Biomech & Implant Technol Res Lab, Doberaner Str 142, D-18057 Rostock, Germany
[3] Inst Polymer Technol eV, Alter Holzhafen 19, D-23966 Wismar, Germany
关键词
Ti6A14V; Selective laser melting; Press-fit; Primary stability; TOTAL HIP-ARTHROPLASTY; IMPROVED PRIMARY FIXATION; POROUS TITANIUM; MECHANICAL-PROPERTIES; SURFACE ARCHITECTURE; INITIAL STABILITY; DESIGN; STEM; IMPLANTS; LASER;
D O I
10.1016/j.jmbbm.2018.01.015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Today hip cups are used in a large variety of design variants and in increasing numbers of units. Their development is steadily progressing. In addition to conventional manufacturing methods for hip cups, additive methods, in particular, play an increasingly important role as development progresses. The present paper describes a modified cup model developed based on a commercially available press-fit cup (Allofit 54/JJ). The press-fit cup was designed in two variants and manufactured using selective laser melting (SLM). Variant 1 (Ti) was modeled on the Alio& cup using an adapted process technology. Variant 2 (Ti-S) was provided with a porous load bearing structure on its surface. In addition to the typical (complete) geometry, both variants were also manufactured and tested in a reduced shape where only the press-fit area was formed. To assess the primary stability of the press-fit cups in the artificial bone cavity, pull-out and lever-out tests were carried out. Exact fit conditions and two-millimeter press-fit were investigated. The closed-cell PU foam used as an artificial bone cavity was mechanically characterized to exclude any influence on the results of the investigation. The pull-out forces of the Ti-variant (complete-526 N, reduced-468 N) and the Ti-S variant (complete-548 N, reduced-526 N) as well as the lever-out moments of the Ti-variant (complete-10 Nm, reduced-9.8 Nm) and the Ti-S variant (complete-9 Nm, reduced-7.9 N) show no significant differences in the results between complete and reduced cups. The results show that the use of reduced cups in a press-fit design is possible within the scope of development work.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] Initial Stability of Press-Fit Acetabular Components Under Rotational Forces
    Fehring, Keith A.
    Owen, John R.
    Kurdin, Anton A.
    Wayne, Jennifer S.
    Jiranek, William A.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (05): : 1038 - 1042
  • [22] Acetabular component deformation with press-fit fixation
    Squire, Matthew
    Griffin, William L.
    Mason, Bohannon
    Peindl, Richard D.
    Odum, Susan
    JOURNAL OF ARTHROPLASTY, 2006, 21 (06): : 72 - 77
  • [23] Experimental investigations of the insertion and deformation behavior of press-fit and threaded acetabular cups for total hip replacement
    Fritsche, Andreas
    Bialek, Kristin
    Mittelmeier, Wolfram
    Simnacher, Martin
    Fethke, Klaus
    Wree, Andreas
    Bader, Rainer
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2008, 13 (03) : 240 - 247
  • [24] Effect of cementless acetabular cup geometry on strain distribution and press-fit stability
    Ries, MD
    Harbaugh, M
    Shea, J
    Lambert, R
    JOURNAL OF ARTHROPLASTY, 1997, 12 (02): : 207 - 212
  • [25] Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins
    Wolfgang O. Huber
    Philip C. Noble
    International Orthopaedics, 2014, 38 : 725 - 731
  • [26] Acetabular strains produced by oversized press fit cups
    Ries, MD
    Harbaugh, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (334) : 276 - 281
  • [27] Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins
    Huber, Wolfgang O.
    Noble, Philip C.
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) : 725 - 731
  • [28] Press-fit cementless acetabular fixation with and without screws
    Ni, Sheng-Hui
    Guo, Lei
    Jiang, Tian-Long
    Zhao, Jie
    Zhao, Yan-Gang
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (01) : 7 - 12
  • [29] Late loosening of press-fit cementless acetabular components
    Jiranek, WA
    Whiddon, DR
    Johnstone, WT
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (418) : 172 - 178
  • [30] Press-fit cementless acetabular fixation with and without screws
    Sheng-Hui Ni
    Lei Guo
    Tian-Long Jiang
    Jie Zhao
    Yan-Gang Zhao
    International Orthopaedics, 2014, 38 : 7 - 12