An interleukin-6 ZnO/SiO2/Si surface acoustic wave biosensor

被引:71
|
作者
Krishnamoorthy, Soumya [1 ]
Iliadis, Agis A. [1 ,2 ]
Bei, Thaleia [3 ]
Chrousos, George P. [4 ,5 ]
机构
[1] Univ Maryland, Dept Elect & Comp Engn, College Pk, MD 20742 USA
[2] Univ Aegean, Dept Informat & Commun Syst Engn, Aegean, Greece
[3] NICHHD, Sect Endocrinol & Genet, Dev Endocrinol Branch, NIH, Bethesda, MD 20892 USA
[4] NIH, Sect Pediat Endocrinol, Reprod & Mol Biol Branch, Bethesda, MD 20892 USA
[5] Univ Athens, Sch Med, Dept Pediat 1, GR-11527 Athens, Greece
来源
BIOSENSORS & BIOELECTRONICS | 2008年 / 24卷 / 02期
基金
美国国家科学基金会;
关键词
interleukin-6; ZnO; SAW biosensor; protein immobilization; SiO2/Si;
D O I
10.1016/j.bios.2008.04.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel high sensitivity ZnO/SiO2/Si Love mode surface acoustic wave (SAW) biosensor for the detection of interleukin-6 (IL-6), is reported. The biosensors operating at 747.7 MHz and 1.586 GHz were functionalized by immobilizing the monoclonal IL-6 antibody onto the ZnO biosensor surface both through direct surface adsorption and through covalent binding on gluteraldehyde. The morphology of the IL-6 antibody-protein complex was studied using scanning electron microscopy (SEM), and the mass of the IL-6 protein immobilized on the surface was measured from the frequency shift of the SAW resonator biosensor. The biosensor was shown to have extended linearity, which was observed to improve with higher sensor frequency and for IL-6 immobilization through the monoclonal antibody. Preliminary results of biosensor measurements of low levels of IL-6 in normal human serum are reported. The biosensor can be fully integrated with CMOS Si chips and developed as a portable real time detection system for the interleukin family of proteins in human serum. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:313 / 318
页数:6
相关论文
共 50 条
  • [41] Investigation of surface acoustic waves propagating in ZnO-SiO2-Si multilayer structure
    Zhang, Zuwei
    Wen, Zhiyu
    Wang, Chunmei
    ULTRASONICS, 2013, 53 (02) : 363 - 368
  • [42] Surface immobilization of peptides on SiO2 nanobeads for a protease biosensor
    Weilbaecher, C
    Grant, SA
    2005 IEEE SENSORS, VOLS 1 AND 2, 2005, : 436 - 439
  • [43] Determination of SiO2 thickness at the interface of ZnO/Si by ellipsometry
    Liu, Yuchan
    Hsieh, Jang-Hsing
    Tung, Siew Kong
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2007, 46 (9A): : 6068 - 6070
  • [44] Formation of ZnO Nanostructures Grown on Si and SiO2 Substrates
    Lee, Seungjin
    Park, Eunkyung
    Lee, Jongtack
    Park, Taehee
    Lee, Sang-hwa
    Kim, Jae-yong
    Yi, Whikun
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (09) : 6264 - 6268
  • [45] UNIAXIALLY STRAINED ZNO/SIO2/SI SAW RESONATORS
    MARTIN, SJ
    GUNSHOR, RL
    PIERRET, RF
    GORODETSKY, G
    ELECTRONICS LETTERS, 1982, 18 (24) : 1030 - 1031
  • [46] Temperature compensation of SAW in ZnO/SiO2/Si structure
    Wu, P
    Emanetoglu, NW
    Tong, X
    Lu, Y
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 211 - 214
  • [47] A ZnO/SiO2/Si (100) love mode transducer
    Kalantar-zadeh, K
    Wlodarski, W
    Holland, A
    Reeves, G
    COMMAD 2000 PROCEEDINGS, 2000, : 367 - 370
  • [48] OPTICALLY ACTIVATED ZNO/SIO2/SI CANTILEVER BEAMS
    SUSKI, J
    LARGEAU, D
    STEYER, A
    VANDEPOL, FCM
    BLOM, FR
    SENSORS AND ACTUATORS A-PHYSICAL, 1990, 24 (03) : 221 - 225
  • [49] SPUTTERING EFFECTS IN SI, SIO2 AND THE SI/SIO2 INTERFACE
    DOWNEY, SW
    EMERSON, AB
    SURFACE AND INTERFACE ANALYSIS, 1993, 20 (01) : 53 - 59
  • [50] X-ray diffraction and surface acoustic wave analysis of BST/Pt/TiO2/SiO2/Si thin films
    Mseddi, Souhir
    Njeh, Anouar
    Schneider, Dieter
    Fuess, Hartmut
    Ben Ghozlen, Mohamed Hedi
    JOURNAL OF APPLIED PHYSICS, 2011, 110 (10)