Cooling Systems for IT Environment Heat Removal in (Internet) Data Centers

被引:6
|
作者
Cho, Jinkyun
Lim, Taisub [1 ]
Kim, Byungseon Sean [1 ]
机构
[1] Yonsei Univ, Dept Architectural Engn, Seoul 120749, South Korea
关键词
(Internet) Data Center; IT environment; IT server; heat load; cooling system; air distribution system; CRAC/CRAH;
D O I
10.3130/jaabe.7.387
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Internet Data Center (IDC) heat removal is one of the most essential yet least understood of all critical IT environment processes. The cooling of data centers has emerged as a significant challenge as the density of computing equipment increases. In this research, environmental aspects of energy consumption and load-profile were studied through the survey of domestic data centers that need all year round cooling load. The energy-using patterns of cooling system combined with real power density are compared and energy saving effects of data center is reviewed. All cooling systems use CRAC or CRAH units of some kind, which come in various capacities and remove the heat from the room. There are five heat removal methods and two common physical equipment arrangements that can be combined to create ten basic types of cooling systems. Air supply and air return systems each have three and four different configurations that can be combined to create thirteen basic types. An understanding of the many types of cooling/air distribution systems and their attributes can be used to develop guidelines for when each type should be used, and such guidelines are provided in this study for both raised floor and hard floor applications. The design criteria of cooling and air distribution systems were analyzed using quantitative data acquired by surveying 20 multi-megawatt data centers in Korea. It provides the best configurations and design criteria for different IT environments and common practices and equipment options that may increase cooling system availability.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 50 条
  • [1] Efficient Cooling and Heat Recovery with VRF Systems in Embedded Data Centers
    Sweeney, Micah
    Khattar, Mukesh
    Domitrovic, Ron
    [J]. 2018 ASHRAE WINTER CONFERENCE, 2018,
  • [2] Efficient cooling and heat recovery with VRF systems in embedded data centers
    Sweeney, Micah
    Khattar, Mukesh
    Domitrovic, Ron
    [J]. ASHRAE Journal, 2019, 61 (02): : 42 - 51
  • [3] Efficient Cooling and Heat Recovery with VRF Systems in Embedded Data Centers
    Sweeney, Micah
    Khattar, Mukesh
    Domitrovic, Ron
    [J]. ASHRAE JOURNAL, 2019, 61 (02) : 42 - 51
  • [4] REFRIGERATION HEAT EXCHANGER SYSTEMS FOR SERVER RACK COOLING IN DATA CENTERS
    Tsukamoto, Takeshi
    Takayoshi, Jyunji
    Schmidt, Roger R.
    Iyengar, Madhusudan K.
    [J]. IPACK 2009: PROCEEDINGS OF THE ASME INTERPACK CONFERENCE 2009, VOL 2, 2010, : 915 - 921
  • [5] Analyzing the Cooling Efficiency of the Thermal Environment in Data Centers
    Xu, Yongmei
    Zhang, Jingru
    Deng, Yuhui
    Du, Lan
    Jiao, Rong
    [J]. INTERNATIONAL JOURNAL OF GRID AND HIGH PERFORMANCE COMPUTING, 2014, 6 (04) : 15 - 27
  • [6] Review on Cooling System Energy Consumption in Internet Data Centers
    Amoabeng, Kofi Owura
    Choi, Jong Min
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2016, 24 (04)
  • [7] Integrated power and cooling systems for data centers
    Herold, KE
    Radermacher, R
    [J]. ITHERM 2002: EIGHTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, PROCEEDINGS, 2002, : 808 - 811
  • [8] Study on Free Cooling Systems for Data Centers in Japan
    Udagawa, Yosuke
    Waragai, Shisei
    Yanagi, Masahide
    Fukumitsu, Wataru
    [J]. 32ND INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2010,
  • [9] DEVELOPMENT OF ADVANCED COOLING NETWORK SYSTEMS FOR DATA CENTERS
    Abe, Yoshiyuki
    Ouchi, Mayumi
    Fukagaya, Masato
    Kitagawa, Takashi
    Ohta, Haruhiko
    Shinmoto, Yasuhisa
    Sato, Masahide
    Iimura, Ken-ichi
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010 , VOL 3: COMBUSTION, CONDUCTION, ELECTRONIC COOLING, EVAPORATION,TWO-PHASE FLOW, 2010, : 425 - 430
  • [10] Modeling of air conditioning systems for cooling of data centers
    Anton, R
    Jonsson, H
    Palm, B
    [J]. ITHERM 2002: EIGHTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, PROCEEDINGS, 2002, : 552 - 558