Efficient Cooling and Heat Recovery with VRF Systems in Embedded Data Centers

被引:0
|
作者
Sweeney, Micah [1 ]
Khattar, Mukesh [2 ]
Domitrovic, Ron [3 ]
机构
[1] EPRI, Knoxville, TN 37932 USA
[2] EPRI, Palo Alto, CA USA
[3] EPRIs Res End Use Energy Efficiency & Demand Resp, Knoxville, TN USA
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Data centers house the information technology (IT) equipment that powers the modern world. These facilities range in size from small networking closets to ware-house-scale buildings operated by large Internet companies. While discussions of data centers often focus on the latter, industry experts estimate that small and mid-size data centers house 40% of all servers in the United States (NRDC, 2014), which are embedded in office buildings, schools, banks, hospitals, and a variety of commercial facilities. These small data centers are estimated to account for 49% of the energy consumed by the data center industry, which as a whole was estimated to represent 70 billion kWh in 2014 (LBNL, 2016). With an estimated 2.5 million small data centers in the U.S.-over 10 times as many as all fast-food restaurants combined-these buildings represent an enormous opportunity for energy savings that often goes overlooked.
引用
收藏
页码:42 / 51
页数:7
相关论文
共 50 条
  • [1] Efficient Cooling and Heat Recovery with VRF Systems in Embedded Data Centers
    Sweeney, Micah
    Khattar, Mukesh
    Domitrovic, Ron
    [J]. 2018 ASHRAE WINTER CONFERENCE, 2018,
  • [2] A novel heat recovery VRF system: Principle and cooling performance analysis
    Liu, Shurong
    Yu, Tianchan
    Wang, Baolong
    Lyu, Hongmei
    Gao, Ru
    Shi, Wenxing
    [J]. BUILDING AND ENVIRONMENT, 2024, 266
  • [3] Cooling Systems for IT Environment Heat Removal in (Internet) Data Centers
    Cho, Jinkyun
    Lim, Taisub
    Kim, Byungseon Sean
    [J]. JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2008, 7 (02) : 387 - 394
  • [4] Gen 3 "Embedded" Cooling: Key Enabler for Energy Efficient Data Centers
    Bar-Cohen, Avram
    [J]. IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2017, 7 (08): : 1206 - 1211
  • [5] Novel Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources
    Chiriac, Victor Adrian
    Chiriac, Florea
    [J]. 2012 13TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2012, : 814 - 820
  • [6] REFRIGERATION HEAT EXCHANGER SYSTEMS FOR SERVER RACK COOLING IN DATA CENTERS
    Tsukamoto, Takeshi
    Takayoshi, Jyunji
    Schmidt, Roger R.
    Iyengar, Madhusudan K.
    [J]. IPACK 2009: PROCEEDINGS OF THE ASME INTERPACK CONFERENCE 2009, VOL 2, 2010, : 915 - 921
  • [7] Power quality assessment of energy efficient cooling systems in data centers
    Mousavi, Arash
    Yavarian, Alireza
    Vyatkin, Valeriy
    Zhang, Xiaojing
    [J]. IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 7191 - 7196
  • [8] Smart distribution of IT load in energy efficient data centers with focus on cooling systems
    Berezovskaya, Yulia
    Mousavi, Arash
    Vyatkin, Valeriy
    Zhang, Xiaojing
    [J]. IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 4907 - 4912
  • [9] Experimental investigation and application analysis on an integrated system of free cooling and heat recovery for data centers
    Ding, Jing
    Zhang, Hainan
    Leng, Dongmei
    Xu, Hongbo
    Tian, Changqing
    Zhai, Zhiqiang
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 136 : 142 - 151
  • [10] Integrated power and cooling systems for data centers
    Herold, KE
    Radermacher, R
    [J]. ITHERM 2002: EIGHTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, PROCEEDINGS, 2002, : 808 - 811