Establishing a usability cut-point for the health information technology usability evaluation scale (Health-ITUES)

被引:7
|
作者
Loh, Kah Poh [1 ]
Liu, Jianfang [2 ]
Ganzhorn, Sarah [2 ]
Sanabria, Gabriella [3 ]
Schnall, Rebecca [2 ]
机构
[1] Univ Rochester, James P Wilmot Canc Inst, Dept Med, Div Hematol Oncol,Med Ctr, Rochester, NY USA
[2] Columbia Univ, Sch Nursing, New York, NY USA
[3] Univ S Florida, Coll Publ Hlth, Tampa, FL USA
基金
美国医疗保健研究与质量局;
关键词
Mobile health; Usability; Information technology; Health-ITUES; SELF-MANAGEMENT; THINK-ALOUD; MOBILE; APP; LITERACY; ADULTS;
D O I
10.1016/j.ijmedinf.2022.104713
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective: The Health Information Technology Usability Evaluation Scale (Health-ITUES) is a validated and reliable instrument to evaluate usability of information technology (IT) tools. In this study, we aimed to establish the optimal cut-point of the Health-ITUES to identify usability of IT tools. Methods: Adult participants were recruited to a trial evaluating a mobile app for self-managing HIV. Participants completed the Health-ITUES at the 3- and 6-month follow-up. Health-ITUES is a 20-item questionnaire that assesses four subscales: impact, perceived usefulness, perceived ease of use, and user control. The total score ranged from 1 to 5 and a higher score indicates greater usability. App use was defined as the proportion of activities completed by participants in both study arms. The selection of an optimal cut-point involved a series of multiple linear regression models with 500 bootstrap replications to examine the relationship between the Health-ITUES total score and app use, controlling for potential covariates. Results: We included 158 participants; mean age was 49.7 years (SD 10.3), 71% were African American/Black, and 72% were non-Hispanic. Mean Health-ITUES total scores at 3 and 6 months were 4.39 (SD 0.75) and 4.43 (SD 0.75), respectively. App use completed by participants from baseline to the 3-month follow-up visits was 0.61 (SD 0.36, range 0-1.72) and from 3-month to the 6-month follow-up visits was 0.51 (SD 0.37). Participants who reported greater Health-ITUES total score completed more activities [beta = 0.18, 95% Confidence Interval (CI) 0.10-0.27]. The optimal cut-point of 4.32 (95% CI: 4.25-4.56) yielded the lowest p-value to identify usability of IT tools. Conclusions: In this study of adults with HIV, we identified an optimal cut-point of 4.32 on the Health-ITUES total score to define usability. Further studies are needed to validate this cut-point.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparative Usability Evaluation of a Mobile Health App
    Veldsman, Alida
    Van Greunen, Darelle
    [J]. 2017 IST-AFRICA WEEK CONFERENCE (IST-AFRICA), 2017,
  • [22] Perceived usability evaluation of educational technology using the System Usability Scale (SUS): A systematic review
    Vlachogianni, Prokopia
    Tselios, Nikolaos
    [J]. JOURNAL OF RESEARCH ON TECHNOLOGY IN EDUCATION, 2022, 54 (03) : 392 - 409
  • [23] Evaluation of usability of a neonatal health information system according to the user's perception
    Padrini-Andrade, Lucio
    Xavier Balda, Rita de Cassia
    Nema Areco, Kelsy Catherina
    Bandiera-Paiva, Paulo
    Nunes, Marynea do Vale
    Martins Marba, Sergio Tadeu
    de Carvalho, Werther Brunow
    Suppo de Souza Rugolo, Ligia Maria
    Carvalho de Almeida, Joao Henrique
    Procianoy, Renato Soibelmann
    Muniz Bandeira Duarte, Jose Luiz
    Santiago Rego, Maria Albertina
    de Lima Mota Ferreira, Daniela Marques
    Alves Filho, Navantino
    Guinsburg, Ruth
    de Albuquerque Diniz, Edna Maria
    Ferraz dos Santos, Juliana Paula
    Testoni, Daniela
    de Mello e Silva, Nathalia Moura
    Conde Gonzales, Maria Rafaela
    Cavalcante da Silva, Regina Vieira
    Meneses, Jucille
    Goncalves-Ferri, Walusa Assad
    Perussi-e-Silva, Ricardo
    Bomfim, Olga
    [J]. REVISTA PAULISTA DE PEDIATRIA, 2019, 37 (01) : 90 - 96
  • [24] Comparison of two heuristic evaluation methods for evaluating the usability of health information systems
    Khajouei, Reza
    Gohari, Sadrieh Hajesmaeel
    Mirzaee, Moghaddameh
    [J]. JOURNAL OF BIOMEDICAL INFORMATICS, 2018, 80 : 37 - 42
  • [25] Usability and Evaluation of a Health Information System in the Emergency Department: Mixed Methods Study
    Ostervang, Christina
    Jensen, Charlotte Myhre
    Coyne, Elisabeth
    Dieperink, Karin B.
    Lassen, Annmarie
    [J]. JMIR HUMAN FACTORS, 2024, 11
  • [26] User perspectives on the usability of a regional health information exchange
    Gadd, Cynthia S.
    Ho, Yun-Xian
    Cala, Cather Marie
    Blakemore, Dana
    Chen, Qingxia
    Frisse, Mark E.
    Johnson, Kevin B.
    [J]. JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2011, 18 (05) : 711 - 716
  • [27] Accessibility and usability of a digital TV health information database
    Thompson, D
    Williams, P
    Nicholas, D
    Huntington, P
    [J]. ASLIB PROCEEDINGS, 2002, 54 (05): : 294 - 308
  • [28] Ten factors to consider when developing usability scenarios and tasks for health information technology
    Russ, Alissa L.
    Saleem, Jason J.
    [J]. JOURNAL OF BIOMEDICAL INFORMATICS, 2018, 78 : 123 - 133
  • [29] USABILITY TESTING OF A NOVEL, HEALTH INFORMATION TECHNOLOGY TOOL FOR BEHAVIOR CHANGE AMONG ADOLESCENTS
    Kepper, Maura
    Walsh-Bailey, Callie
    Garbutt, Jane
    Brownson, Ross C.
    Foraker, Randi
    [J]. ANNALS OF BEHAVIORAL MEDICINE, 2021, 55 : S493 - S493
  • [30] A Health Literacy and Usability Heuristic Evaluation of a Mobile Consumer Health Application
    Monkman, Helen
    Kushniruk, Andre
    [J]. MEDINFO 2013: PROCEEDINGS OF THE 14TH WORLD CONGRESS ON MEDICAL AND HEALTH INFORMATICS, PTS 1 AND 2, 2013, 192 : 724 - 728