Reproducibility of Nerve Fiber Layer Thickness Measurements Using 3D Fourier-Domain OCT

被引:83
|
作者
Menke, Marcel N. [1 ]
Knecht, Pascal [1 ]
Sturm, Veit [1 ]
Dabov, Simeon [2 ]
Funk, Jens [1 ]
机构
[1] Univ Zurich USZ, Dept Ophthalmol, CH-8091 Zurich, Switzerland
[2] Univ Munster, Sch Med, Munster, Germany
关键词
D O I
10.1167/iovs.07-1435
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Conventional time-domain optical coherence tomography (OCT) has been shown to provide reproducible retinal nerve fiber layer (RNFL) measurements. Recently, high-speed, high-resolution Fourier-domain 3D-OCT has been introduced to improve OCT quality. It can provide 6-mm(2) high-density scans to provide RNFL thickness measurements. The purpose of this study was to test the reproducibility of 3D-OCT RNFL thickness measurements in healthy volunteers. METHODS. Thirty-eight eyes were included in the study. High-density 6-mm(2) 3D scans were registered by two independent operators. RNFL thickness was calculated for eight areas corresponding to the ETDRS areas and for two ring areas. The ETDRS grid was centered on the optic disc. Intraclass correlation coefficients (ICC) and coefficients of variation (COV) were calculated. Interobserver reproducibility was visualized by using Bland-Altman analysis. RESULTS. Intrasession reproducibility was good with a mean ICC of 0.90. The mean COV for operator 1 and 2 was 4.2% and 4%, respectively (range, 1.9%-6.7%). Highest reproducibility was found for the two ring areas and the superior and inferior quadrants. Mean differences in RNFL thickness measurements for ring 1 and 2 between operator 1 and 2 were 0.9 mu m (limits of agreement, -11.4 to +9.6 mu m) and 0.1 mu m (limits of agreement -4.1 to +3.9 mu m), respectively. CONCLUSIONS. 3D-OCT RNFL thickness measurements in healthy volunteers showed good intra- and interobserver reproducibility. 3D-OCT provides more RNFL thickness information compared to conventional time-domain OCT measurements and may be useful for the management of glaucoma and other optic neuropathies. (Invest Ophthalmol Vis Sci. 2008;49:5386-5391) DOI: 10.1167/iovs.07-1435
引用
收藏
页码:5386 / 5391
页数:6
相关论文
共 50 条
  • [21] In Vivo 3D Meibography of the Human Eyelid Using Real Time Imaging Fourier-Domain OCT
    Hwang, Ho Sik
    Shin, Jun Geun
    Lee, Byeong Ha
    Eom, Tae Joong
    Joo, Choun-Ki
    [J]. PLOS ONE, 2013, 8 (06):
  • [22] Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography
    Schuman, JS
    PedutKloizman, T
    Hertzmark, E
    Hee, MR
    Wilkins, JR
    Coker, JG
    Puliafito, CA
    Fujimoto, JG
    Swanson, EA
    [J]. OPHTHALMOLOGY, 1996, 103 (11) : 1889 - 1898
  • [23] Reproducibility of nerve fiber layer thickness measurements using Optical Coherence Tomography
    Williams, JM
    Zangwill, LM
    Berry, CC
    Blumenthal, E
    Girkin, C
    Weinreb, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S75 - S75
  • [24] Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Sood, Amit
    Paliwal, Rahul Omprakash
    Mishra, Rishu Yogesh
    [J]. GALICIAN MEDICAL JOURNAL, 2021, 28 (04)
  • [25] Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
    Budenz, DL
    Chang, RT
    Huang, XR
    Knighton, RW
    Tielsch, JM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2440 - 2443
  • [26] In-vivo human corneal nerve imaging using Fourier-domain OCT
    Shin, Jun Geun
    Lee, Byeong Ha
    Eom, Tae Joong
    Hwang, Ho Sik
    [J]. OPHTHALMIC TECHNOLOGIES XXV, 2015, 9307
  • [27] Comparison of corneal thickness measurements using ultrasound pachymetry, noncontact tonopachy, Pentacam HR, and Fourier-domain OCT
    Kim, Jung Sub
    Rho, Chang Rae
    Cho, Yeon Woo
    Shin, Jeongah
    [J]. MEDICINE, 2021, 100 (16) : E25638
  • [28] Effect of Cataract and Its Removal on Ganglion Cell Complex Thickness and Peripapillary Retinal Nerve Fiber Layer Thickness Measurements by Fourier-Domain Optical Coherence Tomography
    Nakatani, Yusuke
    Higashide, Tomomi
    Ohkubo, Shinji
    Takeda, Hisashi
    Sugiyama, Kazuhisa
    [J]. JOURNAL OF GLAUCOMA, 2013, 22 (06) : 447 - 455
  • [29] Repeatability of Measurements from Fourier-Domain OCT for Detecting Ectatic Diseases of Corneal Epithelial Thickness
    Caiado Canedo, Ana Laura
    Valbon, Bruno F.
    Correa, Rosane
    Ambrosio, Renato
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [30] REPRODUCIBILITY OF NERVE-FIBER LAYER THICKNESS MEASUREMENTS USING OPTICAL COHERENCE TOMOGRAPHY
    SCHUMAN, JS
    HEE, MR
    PEDUTKLOIZMAN, T
    WONG, C
    ARYA, AV
    HERTZMARK, E
    PULIAFITO, CA
    FUJIMOTO, JG
    SWANSON, EA
    IZATT, JA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S971 - S971