Evaluation of Dosimetric Accuracy in the Treatment of Multiple Brain Metastases With Volumetric Modulated Arc Therapy and Single Isocenter

被引:0
|
作者
Vieira, A. [1 ]
Sakuraba, R. [1 ]
Goncalves, V. [1 ]
Cruz, J. [1 ]
Weltman, E. [1 ]
机构
[1] Hosp Israelita Albert Einstein, Sao Paulo, Brazil
关键词
D O I
10.1016/j.ijrobp.2012.07.2332
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:S872 / S872
页数:1
相关论文
共 50 条
  • [1] Single Isocenter Volumetric Modulated Arc Radiosurgery for Multiple Brain Metastases
    Chang-Halpenny, C. N.
    Rahimian, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E582 - E583
  • [2] Single Isocenter Radiosurgery for the Simultaneous Treatment of Multiple Brain Metastases: Volumetric Modulated Arc Therapy Or Dynamic Conformal Arc?
    Maurer, J.
    Sintay, B.
    Manning, M.
    Wiant, D.
    Liu, H.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3580 - 3580
  • [3] Dosimetric Effect of Rotational Setup Errors in Single-Isocenter Volumetric-Modulated Arc Therapy of Multiple Brain Metastases
    Selvan, Kasirajan Tamil
    Padma, Ganesan
    Revathy, Murugesan Kesavan
    Raj, N. Arunai Nambi
    Senthilnathan, K.
    Babu, P. Ramesh
    [J]. JOURNAL OF MEDICAL PHYSICS, 2019, 44 (02) : 84 - 90
  • [4] Dosimetric Evaluation On Single-Isocenter Versus Multiple-Isocenter Frameless Volumetric Modulated Arc Radiosurgery for Simultaneous Treatment of Multiple Intracranial Metastases
    Huang, Z.
    Feng, Y.
    Luo, C.
    Liu, T.
    Zhu, D.
    Lo, S.
    Mayr, N.
    Yuh, W.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E651 - E651
  • [5] On a single isocenter volumetric modulated arc therapy SRS planning technique for multiple brain metastases
    Hardcastle, Nicholas
    Tome, Wolfgang A.
    [J]. JOURNAL OF RADIOSURGERY AND SBRT, 2012, 2 (01): : 1 - 9
  • [6] FEASIBILITY OF SINGLE-ISOCENTER VOLUMETRIC MODULATED ARC RADIOSURGERY FOR TREATMENT OF MULTIPLE BRAIN METASTASES
    Clark, Grant M.
    Popple, Richard A.
    Young, P. Edward
    Fiveash, John B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01): : 296 - 302
  • [7] Considerations for the Proper Treatment of Multiple Cranial Metastases with Single Isocenter Volumetric Modulated Arc Therapy
    Audet, C.
    Poffenbarger, B.
    Hwang, A.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3383 - 3384
  • [8] Single-Isocenter, Volumetric Modulated Arc Radiosurgery for Multiple Brain Metastases in a Single Session
    Knuthson, A. R.
    Widdel, L.
    Dial, C.
    Petit, J. H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E267 - E267
  • [9] Optimization of Treatment Geometry to Reduce Normal Brain Dose in Radiosurgery of Multiple Brain Metastases with Single–Isocenter Volumetric Modulated Arc Therapy
    Qixue Wu
    Karen Chin Snyder
    Chang Liu
    Yimei Huang
    Bo Zhao
    Indrin J. Chetty
    Ning Wen
    [J]. Scientific Reports, 6
  • [10] Dosimetric Impact of Rotational Setup Errors on Multiple Brain Targets Treated with Single Isocenter Volumetric Modulated Arc Therapy
    Xue, J.
    No, D.
    Zhang, J.
    Wang, H.
    Barbee, D.
    Lymberis, S.
    Silverman, J.
    Das, I.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E615 - E615