Preliminary Study on the Diagnostic Value of Acoustic Radiation Force Impulse Technology for Differentiating Between Benign and Malignant Thyroid Nodules

被引:0
|
作者
Gu, Jiying [1 ]
Du, Lianfang [1 ]
Bai, Min [1 ]
Chen, Huili [1 ]
Jia, Xiao [1 ]
Zhao, Jing [1 ]
Zhang, Xuemei [2 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Sch Med, Dept Ultrasound, Shanghai 200080, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Sch Med, Dept Pathol, Shanghai 200080, Peoples R China
关键词
acoustic radiation force impulse; thyroid nodule; sonography; FINE-NEEDLE-ASPIRATION; IN-VIVO; ELASTOGRAPHY; ULTRASOUND; CANCER; US;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-This study aimed to evaluate the diagnostic value of acoustic radiation force impulse (ARFI) elasticity imaging for differentiating between benign and malignant thyroid lesions. Methods-Hospitalized patients needing thyroid surgery were evaluated. After routine thyroid sonography, the patients underwent ARFI elasticity imaging. Virtual Touch tissue imaging(VTI) and Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA) were used to qualitatively and quantitatively analyze the elasticity and hardness of nodules. For statistical analysis, the Student t test, analysis of variance, and the chi(2) test were used to compare the elastic parameters. Results-Of the 98 thyroid nodules observed in 72 hospitalized patients, 56 were nodular goiters, 16 thyroid adenomas, 4 thyroiditis, and 22 thyroid malignancies, with mean VTQ values +/- SD of 2.034 +/- 0.484, 1.835 +/- 0.364, 2.293 +/- 0.787, and 3.941 +/- 1.393 m/s, respectively. The elastic parameters of malignant nodules were significantly higher than those of benign nodules (P < .001) and the surrounding thyroid parenchyma (P < .001). There was no significant difference between the VTQ value of benign nodules and that of the surrounding normal thyroid parenchyma (P > .05). For differentiating between benign and malignant nodules, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate were 86.36%, 93.42%, 79.17%, 95.95%, and 91.84% based on the standard VTQ value (2.555m/s). In total, 77.6% (59 of 76) of the benign nodules showed softer and equal images in the VTI mode, and 77.3% (17 of 22) of the malignant nodules showed stiffer images (P < .001). Conclusions-Acoustic radiation force impulse imaging has high sensitivity and specificity in evaluating benign and malignant thyroid nodules and therefore had good diagnostic value in clinical applications.
引用
下载
收藏
页码:763 / 771
页数:9
相关论文
共 50 条
  • [1] Diagnostic Value of Acoustic Radiation Force Impulse Quantification in the Differentiation of Benign and Malignant Thyroid Nodules
    Pandey, Niraj Nirmal
    Pradhan, Gaurav Shanker
    Manchanda, Alpana
    Garg, Anju
    ULTRASONIC IMAGING, 2017, 39 (05) : 326 - 336
  • [2] Acoustic Radiation Force Impulse (ARFI) imaging for the distinction between benign and malignant thyroid nodules
    Cihad Hamidi
    Cemil Göya
    Salih Hattapoğlu
    Ömer Uslukaya
    Memik Teke
    Mehmet Sedat Durmaz
    Mehmet Sıddık Yavuz
    Arif Hamidi
    Güven Tekbaş
    La radiologia medica, 2015, 120 : 579 - 583
  • [3] Acoustic Radiation Force Impulse (ARFI) imaging for the distinction between benign and malignant thyroid nodules
    Hamidi, Cihad
    Goya, Cemil
    Hattapoglu, Salih
    Uslukaya, Omer
    Teke, Memik
    Durmaz, Mehmet Sedat
    Yavuz, Mehmet Siddik
    Hamidi, Arif
    Tekbas, Guven
    RADIOLOGIA MEDICA, 2015, 120 (06): : 579 - 583
  • [4] Comparison of Acoustic Radiation Force Impulse Imaging and Strain Elastography in Differentiating Malignant From Benign Thyroid Nodules
    Zhang, Fengjuan
    Zhao, Xinming
    Han, Ruoling
    Du, Min
    Li, Ping
    Ji, Xiaohui
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (12) : 2533 - 2543
  • [5] Diagnostic Value of ARFI (Acoustic Radiation Force Impulse) in Differentiating Benign From Malignant Breast Lesions
    Magalhaes, Mafalda
    Belo-Oliveira, Pedro
    Casalta-Lopes, Joao
    Costa, Yessica
    Goncalo, Manuela
    Gomes, Paula
    Caseiro-Alves, Filipe
    ACADEMIC RADIOLOGY, 2017, 24 (01) : 45 - 52
  • [6] Differentiation of benign from malignant thyroid nodules with acoustic radiation force impulse technique
    Zhuo, J.
    Ma, Z.
    Fu, W-J
    Liu, S-P
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1035):
  • [7] QUANTIFICATION OF ACOUSTIC RADIATION FORCE IMPULSE IN DIFFERENTIATING BETWEEN MALIGNANT AND BENIGN BREAST LESIONS
    Li, Zhencai
    Sun, Junzhong
    Zhang, Jing
    Hu, Dongmei
    Wang, Qiong
    Peng, Kun
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (02): : 287 - 292
  • [8] Value of Contrast-Enhanced Ultrasound and Acoustic Radiation Force Impulse Imaging for the Differential Diagnosis of Benign and Malignant Thyroid Nodules
    He, Yan
    Wang, Xiao Yan
    Hu, Qiao
    Chen, Xue Xue
    Ling, Bing
    Wei, Hai Ming
    FRONTIERS IN PHARMACOLOGY, 2018, 9
  • [9] Acoustic radiation force impulse elastography for differentiation of benign and malignant thyroid nodules with concurrent Hashimoto’s thyroiditis
    Bo-Ji Liu
    Hui-Xiong Xu
    Yi-Feng Zhang
    Jun-Mei Xu
    Dan-Dan Li
    Xiao-Wan Bo
    Xiao-Long Li
    Le-Hang Guo
    Xiao-Hong Xu
    Shen Qu
    Medical Oncology, 2015, 32
  • [10] Acoustic radiation force impulse elastography for differentiation of benign and malignant thyroid nodules with concurrent Hashimoto's thyroiditis
    Liu, Bo-Ji
    Xu, Hui-Xiong
    Zhang, Yi-Feng
    Xu, Jun-Mei
    Li, Dan-Dan
    Bo, Xiao-Wan
    Li, Xiao-Long
    Guo, Le-Hang
    Xu, Xiao-Hong
    Qu, Shen
    MEDICAL ONCOLOGY, 2015, 32 (03)