Value of Contrast-Enhanced Ultrasound and Acoustic Radiation Force Impulse Imaging for the Differential Diagnosis of Benign and Malignant Thyroid Nodules

被引:14
|
作者
He, Yan [1 ]
Wang, Xiao Yan [1 ]
Hu, Qiao [1 ]
Chen, Xue Xue [1 ]
Ling, Bing [1 ]
Wei, Hai Ming [2 ]
机构
[1] Peoples Hosp Guangxi Zhuang Autonomous Reg, Dept Ultrasound, Nanning, Peoples R China
[2] Peoples Hosp Guangxi Zhuang Autonomous Reg, Dept Pathol, Nanning, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
thyroid nodule; contrast-enhanced ultrasound; acoustic radiation force impulse-imaging; shear wave velocity; receiver operating characteristic curve; ULTRASONOGRAPHIC TISSUE QUANTIFICATION; IN-VIVO; ELASTOGRAPHY; UTILITY; PHANTOM;
D O I
10.3389/fphar.2018.01363
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives: To assess the value of contrast-enhanced ultrasound (CEUS) and acoustic radiation force impulse (ARFI) imaging for the differential diagnosis of benign and malignant thyroid nodules. Methods: CEUS was performed in eighty-eight thyroid nodules. The patterns of CEUS were analyzed, and ARFI was then performed. The shear wave velocities (SWVs) of the nodules and the surrounding normal thyroid tissue were obtained. The areas under the curve (AUCs) and cut-off value were obtained by a receiver operating characteristic (ROC) curve analysis. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic rate of each modality were assessed and compared using pathological diagnosis. Results: Among 88 nodules, 29 nodules were malignant and 59 were benign. The sensitivity, specificity, PPV, NPV, and diagnostic rate of CEUS were 79.3, 91.5, 82.1, 90, and 87.5%, respectively. Using a cut-off value of 2.565 m/s for SWV, the sensitivity, specificity, PPV, NPV and diagnostic rate for malignancy were 75.9, 94.9, 88.0, 88.9, and 88.6%, respectively. The AUC was 0.878. The sensitivity, specificity, PPV, NPV and diagnostic rate of CEUS in combination with ARFI were 93.1, 89.8, 81.8, 96.3, and 90.9%, respectively. Conclusion: Both CEUS and ARFI are valuable for the differential diagnosis of benign and malignant thyroid nodules. Combining these two methods can improve the diagnostic rate.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [1] Value of differential diagnosis of contrast-enhanced ultrasound in benign and malignant thyroid nodules with microcalcification
    Gao, Zhixiang
    Lu, Qin
    Yan, Jiping
    ONCOLOGY LETTERS, 2019, 17 (05) : 4545 - 4549
  • [2] ROLE OF CONTRAST-ENHANCED ULTRASOUND IN DIAGNOSIS OF THYROID NODULES IN ACOUSTIC RADIATION FORCE IMPULSE "GRAY ZONE''
    Zhan, Jia
    Diao, Xue-Hong
    Chen, Lin
    Jin, Jia-Mei
    Chen, Yue
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (06): : 1179 - 1186
  • [3] The Value of Chinese Thyroid Imaging Report and Data System Combined With Contrast-Enhanced Ultrasound Scoring in Differential Diagnosis of Benign and Malignant Thyroid Nodules
    Cao, Haiyan
    Fan, Qi
    Zhuo, Shuangshuang
    Qi, Tingyue
    Sun, Hongguang
    Rong, Xin
    Xiao, Xiao
    Zhang, Wen
    Zhu, Linhai
    Wang, Lei
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (07) : 1753 - 1761
  • [4] The value of acoustic radiation force impulse (ARFI) in the differential diagnosis of thyroid nodules
    Zhang, Feng-Juan
    Han, Ruo-Ling
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E686 - E690
  • [5] Contrast-enhanced ultrasound and real-time elastography in the differential diagnosis of malignant and benign thyroid nodules
    Sui, Xin
    Liu, Huai-Jun
    Jia, Hong-Li
    Fang, Qin-Mao
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2016, 12 (02) : 783 - 791
  • [6] RETRACTED: The Application Value of SMI Technology and Contrast-Enhanced Ultrasound in the Differential Diagnosis of Benign and Malignant Thyroid Nodules (Retracted Article)
    Wu, Jiahuan
    Zhan, Tian
    Sun, Honggang
    Wang, Fanbo
    CONTRAST MEDIA & MOLECULAR IMAGING, 2022, 2022
  • [7] Diagnostic Value of Acoustic Radiation Force Impulse Quantification in the Differentiation of Benign and Malignant Thyroid Nodules
    Pandey, Niraj Nirmal
    Pradhan, Gaurav Shanker
    Manchanda, Alpana
    Garg, Anju
    ULTRASONIC IMAGING, 2017, 39 (05) : 326 - 336
  • [8] Acoustic Radiation Force Impulse (ARFI) imaging for the distinction between benign and malignant thyroid nodules
    Cihad Hamidi
    Cemil Göya
    Salih Hattapoğlu
    Ömer Uslukaya
    Memik Teke
    Mehmet Sedat Durmaz
    Mehmet Sıddık Yavuz
    Arif Hamidi
    Güven Tekbaş
    La radiologia medica, 2015, 120 : 579 - 583
  • [9] Acoustic Radiation Force Impulse (ARFI) imaging for the distinction between benign and malignant thyroid nodules
    Hamidi, Cihad
    Goya, Cemil
    Hattapoglu, Salih
    Uslukaya, Omer
    Teke, Memik
    Durmaz, Mehmet Sedat
    Yavuz, Mehmet Siddik
    Hamidi, Arif
    Tekbas, Guven
    RADIOLOGIA MEDICA, 2015, 120 (06): : 579 - 583
  • [10] Virtual Touch Tissue Imaging on Acoustic Radiation Force Impulse Elastography A New Technique for Differential Diagnosis Between Benign and Malignant Thyroid Nodules
    Zhang, Yi-Feng
    He, Yong
    Xu, Hui-Xiong
    Xu, Xiao-Hong
    Liu, Chang
    Guo, Le-Hang
    Liu, Lin-Na
    Xu, Jun-Mei
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (04) : 585 - 595