Value of Contrast-Enhanced Ultrasound and Acoustic Radiation Force Impulse Imaging for the Differential Diagnosis of Benign and Malignant Thyroid Nodules

被引:14
|
作者
He, Yan [1 ]
Wang, Xiao Yan [1 ]
Hu, Qiao [1 ]
Chen, Xue Xue [1 ]
Ling, Bing [1 ]
Wei, Hai Ming [2 ]
机构
[1] Peoples Hosp Guangxi Zhuang Autonomous Reg, Dept Ultrasound, Nanning, Peoples R China
[2] Peoples Hosp Guangxi Zhuang Autonomous Reg, Dept Pathol, Nanning, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
thyroid nodule; contrast-enhanced ultrasound; acoustic radiation force impulse-imaging; shear wave velocity; receiver operating characteristic curve; ULTRASONOGRAPHIC TISSUE QUANTIFICATION; IN-VIVO; ELASTOGRAPHY; UTILITY; PHANTOM;
D O I
10.3389/fphar.2018.01363
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives: To assess the value of contrast-enhanced ultrasound (CEUS) and acoustic radiation force impulse (ARFI) imaging for the differential diagnosis of benign and malignant thyroid nodules. Methods: CEUS was performed in eighty-eight thyroid nodules. The patterns of CEUS were analyzed, and ARFI was then performed. The shear wave velocities (SWVs) of the nodules and the surrounding normal thyroid tissue were obtained. The areas under the curve (AUCs) and cut-off value were obtained by a receiver operating characteristic (ROC) curve analysis. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic rate of each modality were assessed and compared using pathological diagnosis. Results: Among 88 nodules, 29 nodules were malignant and 59 were benign. The sensitivity, specificity, PPV, NPV, and diagnostic rate of CEUS were 79.3, 91.5, 82.1, 90, and 87.5%, respectively. Using a cut-off value of 2.565 m/s for SWV, the sensitivity, specificity, PPV, NPV and diagnostic rate for malignancy were 75.9, 94.9, 88.0, 88.9, and 88.6%, respectively. The AUC was 0.878. The sensitivity, specificity, PPV, NPV and diagnostic rate of CEUS in combination with ARFI were 93.1, 89.8, 81.8, 96.3, and 90.9%, respectively. Conclusion: Both CEUS and ARFI are valuable for the differential diagnosis of benign and malignant thyroid nodules. Combining these two methods can improve the diagnostic rate.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] AN ALGORITHM OF IMAGE HETEROGENEITY WITH CONTRAST-ENHANCED ULTRASOUND IN DIFFERENTIAL DIAGNOSIS OF SOLID THYROID NODULES
    Jin, Lifang
    Xu, Changsong
    Xie, Xueqian
    Li, Fan
    Lv, Xiuhong
    Du, Lianfang
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (01): : 104 - 110
  • [32] Virtual Touch Tissue Quantification of Acoustic Radiation Force Impulse: A New Ultrasound Elastic Imaging in the Diagnosis of Thyroid Nodules
    Zhang, Yi-Feng
    Xu, Hui-Xiong
    He, Yong
    Liu, Chang
    Guo, Le-Hang
    Liu, Lin-Na
    Xu, Jun-Mei
    PLOS ONE, 2012, 7 (11):
  • [33] Significance of contrast-enhanced ultrasonography in differential diagnosis of thyroid nodules
    Tian, Qing
    Zhu, Haohui
    Li, Hui
    MEDICINE, 2018, 97 (40)
  • [34] Application of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Benign and Malignant Subpleural Pulmonary Lesions
    Shen, MengJun
    Bi, Ke
    Cong, Yang
    Chen, HongWei
    Zhang, Yi
    Zhu, HuiMing
    Wang, Yin
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (05) : 1147 - 1157
  • [35] The Role of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Malignant and Benign Subpleural Lung Lesions
    Boccatonda, Andrea
    Guagnano, Maria Teresa
    D'Ardes, Damiano
    Cipollone, Francesco
    Vetrugno, Luigi
    Schiavone, Cosima
    Piscaglia, Fabio
    Serra, Carla
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (08)
  • [36] COMPARATIVE STUDY OF ACOUSTIC RADIATION FORCE IMPULSE IMAGING WITH REAL-TIME ELASTOGRAPHY IN DIFFERENTIAL DIAGNOSIS OF THYROID NODULES
    Zhan, Jia
    Diao, Xue-Hong
    Chai, Qi-Liang
    Chen, Yue
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (12): : 2217 - 2225
  • [37] Acoustic radiation force impulse elastography for differentiation of benign and malignant thyroid nodules with concurrent Hashimoto’s thyroiditis
    Bo-Ji Liu
    Hui-Xiong Xu
    Yi-Feng Zhang
    Jun-Mei Xu
    Dan-Dan Li
    Xiao-Wan Bo
    Xiao-Long Li
    Le-Hang Guo
    Xiao-Hong Xu
    Shen Qu
    Medical Oncology, 2015, 32
  • [38] QUANTITATIVE SHEAR WAVE VELOCITY MEASUREMENT ON ACOUSTIC RADIATION FORCE IMPULSE ELASTOGRAPHY FOR DIFFERENTIAL DIAGNOSIS BETWEEN BENIGN AND MALIGNANT THYROID NODULES: A META-ANALYSIS
    Liu, Bo-Ji
    Li, Dan-Dan
    Xu, Hui-Xiong
    Guo, Le-Hang
    Zhang, Yi-Feng
    Xu, Jun-Mei
    Liu, Chang
    Liu, Lin-Na
    Li, Xiao-Long
    Xu, Xiao-Hong
    Qu, Shen
    Xing, Mingzhao
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (12): : 3035 - 3043
  • [39] Acoustic radiation force impulse elastography for differentiation of benign and malignant thyroid nodules with concurrent Hashimoto's thyroiditis
    Liu, Bo-Ji
    Xu, Hui-Xiong
    Zhang, Yi-Feng
    Xu, Jun-Mei
    Li, Dan-Dan
    Bo, Xiao-Wan
    Li, Xiao-Long
    Guo, Le-Hang
    Xu, Xiao-Hong
    Qu, Shen
    MEDICAL ONCOLOGY, 2015, 32 (03)
  • [40] Combination of conventional ultrasound and tissue quantification using acoustic radiation force impulse technology for differential diagnosis of small thyroid nodules
    Xing, Ping
    Chen, Qi
    Yang, Zhuo-Wen
    Liu, Chun-Bo
    Wu, Chang-Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (05): : 8288 - 8295